| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 43 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 59 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 287 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1139 days | Next cycle year 2029 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 15, 2023 | STRUCTURALLY COMPROMISED BUILDING FAILURE TO SUBMIT AN ACCEPTABLE INSPECTN RPT FOR STRUCTURALLY COMPROMISED BLDG. #00018 | DOB VIOLATION - ACTIVE |
| Aug 15, 2023 | CONSTRUCTION FTM.DUE TO FIRE THAT ORIGINATD@256 ESSEX ST ON8/2/23,THE 254BLDG WAS DMGD AS FOLLOWS:HOLES IN ROOF,DMGD EXP2 SIDNG,&WATER DMGE THRUOUT UNRELATD TO FIRE,INADEQUATELY SUPPORTD CHIMNEY@EXP2 NEAR 2/3CRNR.OWNR TO RTAIN NYS PE TO EVAL ENT BLDG&FILE RPAIR DWGS.BLDG TO BE RPAIRD UNDR PRMT STRTNG BY9/18/23&C #FEU30502PN | DOB VIOLATION - ACTIVE |
| Aug 2, 2023 | CONSTRUCTION PREMISE NON-COMPLIANT DUE TO A FIRE AND FIRE FIGHTING OPERATIONS FROM THE ADJACENT PREMISE CAUSING AN OPEN ROOF,WINDOWS AND CHARRING AT EXPOSURE 2 EXTERIOR WALL #23-02226 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 5) | Active |
| Oct 15, 2023 | Structurally Compromised Buildings FTF-SC-INITL | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 4, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 7, 2026 |
| Jun 9, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 12, 2025 |
| Apr 10, 2024 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 14, 2024 |
| Mar 22, 2023 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jun 25, 2023 |
| Aug 20, 2008 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT PLASTER CEILING CELLAR THRU OUT. | Sep 24, 2008 |
| Aug 21, 2007 | A | Apt 1L · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 1 STY SOUTH APT 1L BATHROOM LOCATED AT APT 1L | Nov 24, 2007 |
| Aug 21, 2007 | A | Apt 1L · SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ELECTRICAL LIGHT FIXTURE CEILING BATHROOM 1 STY SOUTH APT 1L LOCATED AT APT 1L | Nov 24, 2007 |
| Aug 21, 2007 | B | SECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE REAR YARD | Sep 25, 2007 |
| Aug 21, 2007 | A | Apt 1L · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER SASHES WINDOWS THRU OUT 1 STY SOUTH APT 1L LOCATED AT APT 1L | Nov 24, 2007 |
| Aug 21, 2007 | A | Apt 1L · SECTION 27-2005 ADM CODE REFIT DOOR ENTRANCE TO 1 STY SOUTH APT 1L LOCATED AT APT 1L | Nov 24, 2007 |
| Aug 21, 2007 | B | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES WALLS AND CEILING CELLAR THRU OUT | Sep 25, 2007 |
| Aug 21, 2007 | B | SECTION 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION 1 STY PUBLIC HALL | Sep 25, 2007 |
| Aug 21, 2007 | A | Apt 1L · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HANDLE RADIATOR CONTROL VALVE FRONT ROOM 1 STY SOUTH APT 1L LOCATED AT APT 1L | Nov 24, 2007 |
| Aug 21, 2007 | B | Apt 1L · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALL 1 STY NORTHEAST APT 1L AT KITCHEN LOCATED AT APT 1L | Sep 25, 2007 |
| Aug 21, 2007 | B | Apt 1L · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ENTRANCE DOORS TO 1 STY NORTHEAST APT 1L LOCATED AT APT 1L | Sep 25, 2007 |
| Aug 21, 2007 | B | Apt 1L · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FUSEBOX DOOR BASEMENT FOR APT 1L LOCATED AT APT 1L | Sep 25, 2007 |
| Aug 21, 2007 | B | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRING AT CEILING IN BASEMENT THRU OUT | Sep 25, 2007 |
| Aug 21, 2007 | B | SECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BASEMENT THRU OUT | Sep 25, 2007 |
| Aug 21, 2007 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS MINIMUM REQUIRED | Sep 25, 2007 |
| Aug 21, 2007 | B | SECTION 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES EVIDENCE OF RAT EXCRETA BASEMENT | Sep 25, 2007 |
| Aug 21, 2007 | C | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CASCADING WATER LEAK CEILING 1 STY PUBLIC HALL FRONT ER1. | Aug 27, 2007 |
| Aug 21, 2007 | C | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 1 STY PUBLIC HALL FRONT ER1. | Aug 27, 2007 |
| Aug 21, 2007 | B | Apt 1L · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 1 STY SOUTH APT 1L LOCATED AT APT 1L | Sep 25, 2007 |
| Aug 21, 2007 | B | Apt 1L · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRINGS AT WINDOW 1 STY NORTHEAST APT 1L THRU OUT LOCATED AT APT 1L | Sep 25, 2007 |
| Aug 21, 2007 | B | Apt 1L · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES THRU OUT 1 STY SOUTH APT 1L LOCATED AT APT 1L | Sep 25, 2007 |