4 floors · 4 apartments · 6,436 sq ft · built 2025 · class C3 · owner of record: 253 Gates Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 798 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 26, 2026 | Construction CLASS - 2 ATOI I OBSERVED SIDEWALK SHED INSTALLED AT EXP#1 THAT DOES NOT MEET CODE SPECIFICATION-BRACING FROM POST TO POST INSTALLED AT 7'3" HIGH AT ADJOINING PROPERTY ENTRYWAY(SHALL BE 8'),MUD SILLS BURIED IN DIRT(UNABL #39554648K | Aug 5, 2026 DEFAULT | $10,000 |
| Jul 29, 2025 | Construction CLASS - 1 OBSERVED ACTIVE SITE (EXPOSURE #3). GC FAILED TO PROVIDE PROTECTION FOR EXCAVATION OPERATIONS WHICH POSED AN IMMEDIATE AND SEVERE COLLAPSE HAZARD WHICH WOULD EFFECT PERSONNEL AND THE PUBLIC. STOP ALL EXCAVATIO #39543009K | Dec 11, 2026 DEFAULT | $25,000 |
| Jul 29, 2025 | Site Safety CLASS - 1 UPON REQUEST GC FAILED TO PROVIDE DESIGN DRAWINGS FOR SHORING IN CELLAR LEVEL AND MANUFACTURERS SPECIFICATIONS FOR PUMP JACKS AT EXPOSURE #2 AND #4 ALSO, NO SUPPORT OF EXCAVATION DRAWINGS, NO ACCESS AGREEMENT F #39543013N | Dec 11, 2026 DEFAULT | $12,500 |
| Jul 29, 2025 | Construction CLASS - 1 OBSERVED ACTIVE SITE WITH MULTIPLE COMBUSTIBLE MATERIAL, LARGE AMOUNT OF DEBRIS, OBSTRUCTION OF EGRESS @ EXP.1,3; ROOF LEVEL MATERIAL WITHOUT PROPERLY SECURED FROM THE PUBLIC/ PROPERTY. GC MUST PROVIDE AND MAIN #39543033K | Dec 11, 2026 DEFAULT | $12,500 |
| Jul 29, 2025 | Unknown CLASS - 1 OBSERVED ACTIVE SITE @ EXP1GC FAILED TO PROVIDE THE PUBLIC FROM STAGING EQUIPMENT/MATERIAL; POSED AN IMMEDIATE AND SEVERE HAZARD TO THE PUBLIC BECAUSE THE EQUIPMENT/MATERIAL ACCESSIBILITY TO THE PUBLIC 3307.4.7 #39543012L | Dec 11, 2026 DEFAULT | $10,000 |
| Jul 29, 2025 | Construction CLASS - 1 OBSERVED SITE @ ROOF LEVEL WITHOUT TOE BOARD PROTECTION @ EXP. 1,2,3,4; GC FAILED TO PROTECT THE PUBLIC/PROPERTY BY NOT PROVIDING TOE PROTECTION @ ROOF LEVEL FROM FALLS CONSTRUCTION OBJECTS: EQUIPMENT/MATERIAL #39543034M | Dec 11, 2026 DEFAULT | $25,000 |
| Jul 29, 2025 | Construction CLASS - 1 OBSERVED ACTIVE SITE GC FAILED TO PROVIDE ADEQUATE GUARDRAIL SYSTEM FOR SUPPORT OF EXCAVATION (SOE) @ EXP. 3; ACTIVE CONSTRUCTION PERSONNEL POSES AN IMMEDIATE FALLING HAZARD FOR EXPOSED OPENINGS @ EXP. 3 /EXCEE #39543010H | Dec 11, 2026 DEFAULT | $25,000 |
| Jul 29, 2025 | Construction CLASS - 1 OBSERVED ACTIVE SITE GC FAILED TO PROVIDE OVERHEAD PROTECTION FOR ADJOINING PROPERTY @ EXP.4 DURING ROOF/ FACADE OPERATIONS PER SSP .. STOP ALL ROOF & FACADE OPERATION @ EXP. 4 MUST PROVIDE OVERHEAD PROTECTION #39543011J | Dec 11, 2026 DEFAULT | $25,000 |
| Jul 29, 2025 | Unknown CLASS - 1 OBSERVED ACTIVE SITE WITHOUT FIRE- EXTINGUISHERS @ FIRE EXITS LEVEL 1,2,3,&4 GC MUST MAINTAIN ALL REQUIRED FIRE EXITS AND PASSAGEWAYS WITH FIRE-EXTINGUISHERS IN READINESS PER CODE GC MUST PROVIDE ALL REQUIRED F #39543035Y | Dec 11, 2026 DEFAULT | $6,250 |
| Jul 29, 2025 | Unknown CLASS - 2 ACTIVE SITE/ CS FAILED TO ADDRESS ON SITE CONDITIONS: NO DRAWINGS FOR SHORING, NO MANUFACTURING SPECIFICATIONS FOR SHORING IN CELLAR LEVEL, NO SUPPORT OF EXCAVATION(SOE)DRAWINGS, NO NEIGHBOR'S AGREEMENT, INADEQ #39543044X | May 10, 2027 PENDING | $10,000 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 7:35 PM ET. BBL 3019730054.