15 floors · 267,438 sq ft · built 1894 · class RC · owner of record: Nyc Department Of Citywide Administrative Services
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 267,438 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 801 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 134). Agency page | Dec 31, 2034 in 2992 days | Next due 2034 |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | On file | Cycle 10 filing on record: SAFE (2026-01-13) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 4, 2024 | Construction CLASS - 2 FAILED TO PROVIDE SIDEWALK SHED PARAPET INFORMATION PANEL CONTRARY WITH BC-3301.9.2, CREATING HAZARDOUS FOR FDNY IN EMERGENCY TO EASY LOCATED THE SITE. WHERE A SIDEWALK SHED IS INSTALLED, A SIDEWALK SHED PARAPE #39533133Z | Dec 12, 2024 ADMIT/IN-VIO | $0 |
| May 17, 2023 | Construction CLASS - 1 OBSERVED. SUSPEND THE SCAFFOLDS IN USE WITH NO MANUFACTURE SPECS PROVIDED FOR REMOTE CONTROL/PENDENT. STYROFOAM. C-STIRRUP. NONE WAS PROVIDED CREATING A HAZARDOUS CONDITION FOR PERSONNEL WORKERS USING. SUSPENDE #39516790Y | May 20, 2024 IN VIOLATION | $625 |
| May 17, 2023 | Construction CLASS - 2 ALL WIRE ROPES USED IN HOISTING EQUIPMENT SHALL MEET THE INSPECTION AND REPLACEMENT REQUIREMENTS SPECIFIED IN RULES PROMULGATED BY AND DESCRIBED. BY RULE OF THAT DEPARTMENT.REPLACE AND REMOVE #39516789R | May 20, 2024 IN VIOLATION | $625 |
| Nov 15, 2019 | Construction CLASS - 2 SEC. 27-929.1 A.C.27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS& FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BLDG #37016918K | Jan 23, 2020 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 7, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AS NOTED: AT TIME OF INSPECTION I OBSERVED ON EXPOSURE#3 WEST ELEVATION: SPALLED DAMAGE BRICKS AND WATER TABLE COPING STONE AT THE 17TH FLOOR. REMEDY: REPAIR AND/OR REPLACE ALL DAMAGED MASONRY ON FACADE #SR0105RF | DOB VIOLATION - ACTIVE |
| Sep 3, 2019 | SPRINKLER FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019 #NRF00848 | DOB VIOLATION - ACTIVE |
| Feb 2, 2017 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00009 | DOB VIOLATION - ACTIVE |
| Nov 2, 2016 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00010 | DOB VIOLATION - ACTIVE |
| Aug 2, 2016 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00013 | DOB VIOLATION - ACTIVE |
| Jun 2, 2016 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00017 | DOB VIOLATION - ACTIVE |
| Jan 1, 2012 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00032 | DOB VIOLATION - ACTIVE |
| Dec 21, 2007 | ELEVATOR #9011/229573 | DOB VIOLATION - ACTIVE |
| Dec 28, 2000 | CONSTRUCTION #STF02PM | DOB VIOLATION - ACTIVE |
| Jul 17, 1987 | LOCAL LAW 5/73 #P123 | DOB VIOLATION - ACTIVE |
| Jul 17, 1987 | LOCAL LAW 5/73 #C | DOB VIOLATION - ACTIVE |
| Jul 8, 1980 | LOCAL LAW 5/73 #2-1 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Sep 3, 2019 | Sprinklers FTF-SP-FINAL | Active |
| Feb 2, 2017 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Nov 2, 2016 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Aug 2, 2016 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jun 2, 2016 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jan 1, 2012 | Benchmarking - LL84 FTF-EN-BENCH | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 22, 2026, 12:15 PM ET. BBL 1001347501.