2 floors · 213,338 sq ft · built 1965 · class W1 · owner of record: Nyc Department Of Parks And Recreation
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-15 (Accepted). Agency page | Dec 31, 2026 in 62 days | 2 of 2 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 213,338 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 183 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 183 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1158 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 13655). Agency page | Dec 31, 2035 in 3349 days | Next due 2035 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 13, 2026 | Construction CLASS - 2 REISSUE#35643129H ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY.UPON REVIEW OF DOB RECORDS TEMPORARY CERTIFICATE OF OCCUPANCY#401345594 EXPIRED 09/15/2004.REM:OBTAIN VALID COFO. #35727119M | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 13, 2026 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. NOTED: EXIT DOOR #6 NOT SELF-CLOSING. REMEDY: REPAIR AND/OR REPLACE. #35727122N | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 13, 2026 | Construction CLASS - 2 REISSUE ECB #35678897K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMANNER. NOTED: AT MECHANICAL ROOF PAST TOP APPROX. 200FT OF PARAPET PROTECTIVE RAILING MISSING. REMEDY: PROVIDE PROTECTIVE RAILING. #35727120J | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 13, 2026 | Construction CLASS - 2 REISSUE ECB #35678896Z. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMANNER. NOTED: WATER LEAKS EXISTS AT: FRONT OF ELEVATOR ON 2ND FLOOR, CLASSROOM AND 228, CEILING 2D FLOOR BY STAIR D, INSIDE STAIR D HALLWAY #35727121L | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 13, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: SEVERAL EXIT LIGHTS NOT WORKING THROUGHOUT SCHOOL. REMEDY: REPAIR AND/OR REPLACE. #35727123P | Mar 12, 2026 POP/IN-VIO | $0 |
| Sep 18, 2025 | Boilers CLASS - 2 FOUND BURNHAM GAS FIRED STEAM BOILER NOT OPERATING BECAUSE OF FLOODING OVER SUMMER MONTHS,ALL WIRING IN BURNER CABINET HAS WIRE AND CONTROL DAMAGE CORRECT VIOLATING CONDITION AND SUBMIT A CERTIFICATE OF CORRECT #39160983X | Oct 20, 2025 POP/IN-VIO | $0 |
| Feb 26, 2025 | Construction CLASS - 2 REISSUE #35643129H. ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1-28-118.3.2. NOTED C OF O TEMP. EXPIRED 09/15/2004. NO #401345594. REMEDY: OBTAIN VALID C OF O OR #35692445K | Apr 18, 2025 POP/IN-VIO | $0 |
| Mar 11, 2024 | Construction CLASS - 2 REISSUE #35665285R. ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1-NOTED: TEMPORARY C OF O #401345594 EXPIRED ON 09/15/2004-BUILDING IS OCCUPIED AS A PUBLIC SCHOOL( #35678895R | May 13, 2024 POP/IN-VIO | $0 |
| Mar 11, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT MECHANICAL ROOM ROOF TOP, APPROX. 200FT. OF PARAPET/PROTECTIVE RAILING MISSING. REMEDY: PROVIDE PROTECTIVE RAILLING. #35678897K | May 13, 2024 POP/IN-VIO | $0 |
| Mar 11, 2024 | Construction CLASS - 2 REISSUE #35665287K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT 2ND FLOOR VARIOUS CLASS ROOMS HAVE WATER PENETRATION THROUGH DEFECTIVE ROOF: CLASS ROOM #228, 229, 230, 231, 232, 233, 234, 2 #35678896Z | May 13, 2024 POP/IN-VIO | $0 |
| Feb 13, 2023 | Construction CLASS - 2 REISSUE#35643128X(3/24/22)FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:AT 2ND FLOOR CLASSROOMS(ENTIRE)WINDOW HAS WATER PENETRATION ONTO WALLS,SILLS,CEILING.REM:REPAIR AND OR/REPLACE. #35665286Z | May 30, 2023 POP/IN-VIO | $0 |
| Feb 13, 2023 | Construction CLASS - 2 REISSUE#35643129H ALTERED/BUILDING OCCUPIED WITHOUT VALID COFO AS PER 28-118.3.1,28-118.3.2 COFO RECORDS#401345594 TEMPORARY EXPIRED ON 12/08/2004 AT 1 PERMIT ISSUED ON 2004 NOT SIGNED OFF.REM:OBTAIN VALID COFO #35665285R | May 30, 2023 POP/IN-VIO | $0 |
| Feb 13, 2023 | Construction CLASS - 2 REISSUE#35643129Y(3/24/2022)FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:AT ROOF TOP IN SEVERAL AREA WATER PUDDLE AND LEAKS AND 2NDFLOOR CLASSROOM(S).REM:REPAIR AND OR REPLACE. #35665287K | May 30, 2023 POP/IN-VIO | $0 |
| Mar 24, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED DURING INSPECTION OF 2ND FLOOR ROOMS 228,229,230,231,232,233,234,235,236,237,238,239,240,241,242,243,244,245,246,247 BY THE WINDOWS HAVE WATE #35643128X | Jul 19, 2022 POP/IN-VIO | $0 |
| Mar 24, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED ROOF LEVEL OVER(NEW)ROOM 231 IS POOLING WATER ABOUT 1/2 INCH OF WATER ACROSS THE ENTIRE ROOF.REM:REPAIR AND/OR REPLACE. #35643127Y | Jul 19, 2022 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #08802 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #24292 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #29700 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #45369 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 30, 2026, 2:37 PM ET. BBL 4136550001.