Brooklyn · Block 2524 · Lot 39 · 11222

252 Green Street

3 floors · 16,640 sq ft · built 1931 · class F9 · owner of record: 252 Green Street Llc

5open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
796dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 796 days
Next cycle year 2028

Open violations

ECB / OATH (0)

None open.

DOB (5)
IssuedViolationStatus
May 30, 2024CONSTRUCTION
FAILURE TO MAINTAIN IN A SAFE CONDITION.EXP2 ADJ TO CONC PLANT&EXP4, ABUTTNG ADJ 1STORY BLDG.EXP1 PARAPET W/THRU WALL CRCKS&CRCKS@ 1/2 CRNR &WRAPPNG AROUND TO EXP3@2ND & 3RDFL W/VARIOUS CRK.OWNR TO ENGAGE NYSPE TO EVAL ENT BLDG&FILE RPAIR DWGS W/NYC.PERM RPAIR BLDG UNDR PRMT STRTNG BY 6/24/24&CMPLT/
#FEU30103PN
DOB VIOLATION - ACTIVE
May 28, 2024CONSTRUCTION
FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. UPON INSPECTION OF 3 STORY BUILDING ,I OBSERVED AT EXPO.#1 AND 2 VERTICAL CRACKS AT PARAPET WALLS LEVEL, AS WELL AS BELOW AND ABOVE WINDOWS .
#24-01460
DOB VIOLATION - ACTIVE
Apr 4, 2018CONSTRUCTION
EMERG WRK.3 STRY+CELL MASONRY WALLS&WOOD FRAMED FLRS MIX USE BLDG CRACKED&FALLING STUCCO FOUND THRUOUT.CRACKED BRICK&LEAN PARAPET FOUND ON ALL FACADES.FRONT PARAPET IS LEAN&THERE IS POTENTIAL LOOSE STUCCO DETACH FROM BLDG.REMEDY:OWN IMMED INSTALL SIDEWALK SHED AT FRONT WALL FILE FOR PERM W/48HRS OF
#FEU30102XC
DOB VIOLATION - ACTIVE
Apr 4, 2018CONSTRUCTION
FTM 3 STRY+CELL MASONRY WALLS+WOOD FRAME FLRS MIX USE BLDG.EXT WALLS IN STATE OF DISREPAIR.CRACKED&SPALLING STUCCO FOUND IN VARIOUS LOCS WHERE RPRS WERE DONE PREV.VERT CRACKS FOUND AT REAR.LEAN PARAPETS FOUND ON ALL WALLS.REMEDY:OWN ENGAGE LIC PE&CONT'R EVAL&RPR ALL CONDS FILE PERM FOR RPR WRK NO LA
#FEU30103XC
DOB VIOLATION - ACTIVE
Aug 23, 1998CONSTRUCTION
HAZARDOUS
#NEAC01
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 5:11 AM ET. BBL 3025240039.

Look up another building