19 floors · 352 apartments · 623,668 sq ft · built 1910 · class RM · owner of record: Unavailable Owner
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 66 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $25,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 118 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 623,668 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 774). Agency page | Dec 31, 2034 in 2988 days | Next due 2034 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-04 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 25, 2022 | Construction CLASS - 2 BC 3307.1 STORAGE OR PLACEMENT OF ITEMS-SIDEWALK SHED.NOTE:AT THE TIMEOF MY INSPECTION ON AN ACTIVE JOBSITE,I OBSERVED AN APPROXIMATELY 6 FOOT HIGH PIPE FRAME SETUP COVERED WITH A TARP COVERING WORK-MADE WOODEN #35652830K | Mar 9, 2023 IN VIOLATION | $0 |
| May 25, 2022 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS-CD5.NOTE:AT THE TIME OF MY INSPECTION ON AN ACTIVE JOBSITE FOR FACADE WORK UNDER ALTERATION PERMIT#140929949 IT WAS OBSERVED T #35652829N | Aug 25, 2022 DEFAULT | $0 |
| Feb 10, 2022 | Construction CLASS - 2 3303.16 CONTRACTOR SHED AND OFFICES.NOTED AT THE TIME OF MY INSPECTIONOF AN ACTIVE FACADE RESTORATION JOBSITE,I OBSERVED SHANTI/OFFICE INSTALLED AT ROOF NOT MADE OF METAL OR OTHER NON-COMBUSTIBLE MATERIAL(USED #35633736K | Sep 1, 2022 ADMIT/IN-VIO | $0 |
| Feb 10, 2022 | Construction CLASS - 2 STORAGE ON SIDEWALK SHED(SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS)NOTED AT THE TIME OF MY INSPECTION OF AN ACTIVE FACADE RESTORATION JOBSITE,I OBSERVED BIG AMOUNTS OF EQUIPMENT,MATERIAL(BRICKS,STONES AND #35633737M | Sep 1, 2022 ADMIT/IN-VIO | $0 |
| Feb 10, 2022 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED DOCUMENTS AND/OR AMENDMENTS.NOTED ATTHE TIME OF MY INSPECTION OF ACTIVE CONSTRUCTION JOBSITE,I OBSERVED CHOOK AND OUTRIGGER BEAMS SUSPENDED SCAFFOLD IN USE.UPON REVIEWING CD5 A #35633735Z | Sep 1, 2022 ADMIT/IN-VIO | $0 |
| Oct 20, 2021 | Construction CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR AMENDMENTS-CD5 OUTRIGGERS/DELTA SYSTEM. AT TIME OF INSPECTION AT A 19 STY ALTERATION,I OBSERVED ON ROOF LEVEL ON A ACTIVE FACADE REPAIR SITE,ACTIVE #35591506M | Nov 17, 2022 IN VIOLATION | $0 |
| Aug 5, 2021 | Construction CLASS - 2 DOCUMENTS TO BE KEPT ON SITE AS REQUIRED BY BC CHAPTER 33.AT TIME OF INSPECTION OBSERVED OUTRIGGER BEAMS AT EXP #2 AND #3.WHEN ASKED TO PROVIDE MANUFACTURER SPECS FOR OUTRIGGERS NONE WERE ONSITE.REMEDY:PROVIDE #35580055Z | Mar 17, 2022 DEFAULT | $0 |
| Aug 5, 2021 | Construction CLASS - 1 WORK DOES NOT CONFORM WITH APPROVED PLANS.AT TIME OF INSPECTION OBSERVED SUSPENDED SCAFFOLDS AT EXP #2 AND #3.UPON FURTHER INSPECTION NOTICED THAT DELTA OUTRIGGER BEAMS WERE NOT INSTALLED ACCORDING TO APPORVED #35580054R | Mar 17, 2022 DEFAULT | $0 |
| Mar 25, 2021 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION.NOTED AT THE TIME OF MY INSPECTION OF ACTIVE 19 STORY ALT TYPE 2 CONSTRUCTION JOBSITEI OBSERVED SIDEWALK SHED POST WERE NO PLUMB.THE POST WERE LEANING AT T #35550532P | Mar 24, 2022 IN VIOLATION | $0 |
| Mar 25, 2021 | Construction CLASS - 1 3314.4.3.2 INADEQUATE INSPECTION REPORT.NOTED AT THE TIME OF MY INSPECTION OF ACTIVE FACADE RESTORATION JOBSITE I OBSERVED 3CHOOKS SUSPENDEDSCAFFOLD AT EXP3.UPON REQUEST OF INSTALLATION REPORT NO VIOLATION COND #35550531N | Aug 19, 2021 DEFAULT | $0 |
| Mar 25, 2021 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPORVED CONSTRUCTION OR DOCUMENTS OR AMENDMENTS.NOTE AT THE TIME OF MY INSPECTION OF ACTIVE FACADE RESTORATION JOBSITE,I OBSERVED 5 OUTRIGGER BEAMS SUSPENDED SCAFFOLD AT EXP2.UPON REVI #35550530L | Aug 19, 2021 DEFAULT | $0 |
| Jan 19, 2021 | Construction CLASS - 1 28.201.1 INADEQUATE TENANT PROTECTION PLAN NOTE:AT TIME OF INSPECTION OBSERVED WORK BEING PERFORMED UNDER THE AFOREMENTIONED JOB NUMBER.THE SUBMITTED TPP LACKS SPECIFIC MEANS & METHODS OF PROTECTION TENANTS ON #35541960R | Feb 10, 2022 ADMIT/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00222 | DOB VIOLATION - ACTIVE |
| May 11, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00041 | DOB VIOLATION - ACTIVE |
| Feb 22, 2022 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 #00156 | DOB VIOLATION - ACTIVE |
| Oct 27, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00035 | DOB VIOLATION - ACTIVE |
| Jun 23, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00039 | DOB VIOLATION - ACTIVE |
| Jun 23, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00040 | DOB VIOLATION - ACTIVE |
| Apr 14, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00021 | DOB VIOLATION - ACTIVE |
| Feb 3, 2021 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00005 | DOB VIOLATION - ACTIVE |
| Nov 3, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00008 | DOB VIOLATION - ACTIVE |
| Aug 3, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00023 | DOB VIOLATION - ACTIVE |
| May 3, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00023 | DOB VIOLATION - ACTIVE |
| Jun 6, 2011 | ELEVATOR #9028/386358 | DOB VIOLATION - ACTIVE |
| Jul 14, 2008 | ELEVATOR #9444/268528 | DOB VIOLATION - ACTIVE |
| Jan 29, 2008 | ELEVATOR #9444/235622 | DOB VIOLATION - ACTIVE |
| Jan 29, 2008 | ELEVATOR #9444/235621 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| May 11, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2022 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 | Active |
| Oct 27, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 23, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 23, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 14, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 3, 2021 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Nov 3, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Aug 3, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 3, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 5:45 AM ET. BBL 1007747501.