5 floors · 25 apartments · 22,000 sq ft · built 1923 · class C1 · owner of record: 12th And 14th Street Investor Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 67 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-17 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 5, 2026 | C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Oct 31, 2026 |
| Oct 2, 2026 | B | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. | Nov 6, 2026 |
| Oct 2, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR HANDLE AND LATCH AT PUBLIC HALL, 1st STORY | Nov 6, 2026 |
| Sep 29, 2026 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT BULKHEAD , 5th STORY | Nov 3, 2026 |
| Sep 29, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT BULKHEAD , 5th STORY | Jan 2, 2027 |
| Sep 29, 2026 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT BULKHEAD , 5th STORY | Oct 5, 2026 |
| Sep 8, 2026 | C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF OVER GROWN VEGITATION AT FIRE ESCAPE ALL STORIES AT REAR OF BUILDING | Sep 14, 2026 |
| Sep 8, 2026 | A | Apt 5C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 12, 2026 |
| Sep 3, 2026 | B | Apt 5E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 8, 2026 |
| Aug 31, 2026 | C | Apt 2C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 26, 2026 |
| Aug 31, 2026 | C | Apt 2C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 26, 2026 |
| Aug 31, 2026 | B | Apt 2C · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE BATHROOM LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 5, 2026 |
| Aug 31, 2026 | B | Apt 2C · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 5, 2026 |
| Aug 31, 2026 | B | Apt 5E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 5, 2026 |
| Aug 31, 2026 | C | Apt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 26, 2026 |
| Aug 31, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED PLASTER AT CEILING AT PUBLIC HALL, 5th STORY | Oct 5, 2026 |
| Aug 31, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 5th STORY | Dec 4, 2026 |
| Aug 31, 2026 | B | Apt 2C · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 5, 2026 |
| Aug 27, 2026 | B | Apt 5D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD STOOL AT WINDOW IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 5D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 1, 2026 |
| Aug 27, 2026 | C | Apt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 22, 2026 |
| Aug 27, 2026 | C | Apt 5D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT THE UPPER SASH WINDOW IN THE BATHROOM LOCATED AT APT 5D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 2, 2026 |
| Aug 27, 2026 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE AT CEILING AT BULKHEAD AT PUBLIC HALL | Sep 2, 2026 |
| Aug 27, 2026 | B | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT FRONT OF THE BUILDING AT FIRE ESCAPE | Oct 1, 2026 |
| Aug 27, 2026 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WELDED SHOE AT FRONT OF THE BUILDING AT FIRE ESCAPE | Oct 1, 2026 |
| Aug 27, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER PROTRUDING MORE THAN 4 INCHES BEYOND WINDOW SEAL ON 2ND, 3RD AND 4 STORY BALCONIES AT THE FRONT OF THE BUILDING AT FIRE ESCAPE | Oct 1, 2026 |
| Aug 27, 2026 | A | Apt 5D · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING UPPER AND LOWER ESCUTECHEON PLATES AT HEAT RISER IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Aug 27, 2026 | A | Apt 5E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET OBSEREVE AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Aug 27, 2026 | A | Apt 5D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 5D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Aug 27, 2026 | A | Apt 5E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 30, 2026 |
| Aug 27, 2026 | B | Apt 5D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 1, 2026 |
| Aug 10, 2026 | B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FIRE PASSAGEWAY NORTH YARD | Sep 14, 2026 |
| Aug 10, 2026 | C | Apt 1B · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 1B, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 24, 2026 |
| Aug 10, 2026 | C | Apt 1B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 5, 2026 |
| Jul 8, 2026 | C | Apt 2C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 3, 2026 |
| Jul 8, 2026 | C | Apt 2C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 3, 2026 |
| Apr 8, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT 1ST STORY LEADING TO CELLAR AT BOILER ROOM, 1st STORY | Apr 14, 2026 |
| Mar 16, 2026 | C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING PERMANENTLY INSTALLED KICKSTANDS AT NORTH AND SOUTH DOORS AT BOILER ROOM | Mar 30, 2026 |
| Mar 11, 2026 | C | Apt 2C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Apr 6, 2026 |
| Mar 10, 2026 | C | Apt 2C · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 10, 2026 |
| Aug 28, 2025 | B | Apt 1B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FEET AT CEILING IN THE BATHROOM LOCATED AT APT 1B, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 17866358 ISSUED 24-APR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-201 | Oct 2, 2025 |
| Jul 21, 2025 | C | Apt 2A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 16, 2025 |
| Jun 9, 2025 | C | Apt 2A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 5, 2025 |
| Apr 30, 2025 | B | Apt 1B · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT STEAM RISER AT CEILING IN THE BATHROOM LOCATED AT APT 1B, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 4, 2025 |
| Apr 30, 2025 | B | Apt 3B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE FLOOR IN THE KITCHEN LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 4, 2025 |
| Apr 30, 2025 | B | Apt 1B · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 4, 2025 |
| Apr 30, 2025 | B | Apt 1B · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 4, 2025 |
| Apr 30, 2025 | C | Apt 1B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | May 26, 2025 |
| Apr 30, 2025 | B | Apt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 1B, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 4, 2025 |
| Apr 30, 2025 | B | Apt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 4, 2025 |
| Apr 30, 2025 | A | Apt 3B · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE STEAM RISER IN THE 3rd ROOM FROM EAST LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST | Aug 3, 2025 |
| Mar 18, 2025 | C | Apt 2C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Apr 13, 2025 |
| Jan 7, 2025 | B | Apt 5C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FEET AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 5C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 17251345 ISSUED 06-SEP-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE COD | Feb 11, 2025 |
| Oct 17, 2024 | C | Apt 2A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | Nov 12, 2024 |
| Jun 14, 2024 | C | Apt 2A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jul 10, 2024 |
| Jun 5, 2023 | C | Apt 2C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 1, 2023 |
| Apr 15, 2021 | B | Apt 2A · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HINGES AT DOORS 2ND ,4TH AND 5TH FROM SOUTH AT EAST WALL CABINET IN THE KITCHEN LOCATED AT APT 2A, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | May 20, 2021 |
| Apr 15, 2021 | B | Apt 2A · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HINGES AT DOOR 1ST, 4TH, 5TH FROM SOUTH AT EAST BASE CABINET IN THE KITCHEN LOCATED AT APT 2A, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | May 20, 2021 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 5, 2026 | HPD C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Open |
| Oct 2, 2026 | HPD B | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. | Open |
| Oct 2, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR HANDLE AND LATCH AT PUBLIC HALL, 1st STORY | Open |
| Sep 29, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT BULKHEAD , 5th STORY | Open |
| Sep 29, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT BULKHEAD , 5th STORY | Open |
| Sep 29, 2026 | HPD C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT BULKHEAD , 5th STORY | Open |
| Sep 8, 2026 | HPD C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF OVER GROWN VEGITATION AT FIRE ESCAPE ALL STORIES AT REAR OF BUILDING | Open |
| Sep 8, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 3, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Aug 31, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 31, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 31, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE BATHROOM LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 31, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 31, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Aug 31, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Aug 31, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED PLASTER AT CEILING AT PUBLIC HALL, 5th STORY | Open |
| Aug 31, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 5th STORY | Open |
| Aug 31, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 27, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD STOOL AT WINDOW IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 5D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 27, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 27, 2026 | HPD C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT THE UPPER SASH WINDOW IN THE BATHROOM LOCATED AT APT 5D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 27, 2026 | HPD C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE AT CEILING AT BULKHEAD AT PUBLIC HALL | Open |
| Aug 27, 2026 | HPD B | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT FRONT OF THE BUILDING AT FIRE ESCAPE | Open |
| Aug 27, 2026 | HPD B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WELDED SHOE AT FRONT OF THE BUILDING AT FIRE ESCAPE | Open |
| Aug 27, 2026 | HPD B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER PROTRUDING MORE THAN 4 INCHES BEYOND WINDOW SEAL ON 2ND, 3RD AND 4 STORY BALCONIES AT THE FRONT OF THE BUILDING AT FIRE ESCAPE | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 7:07 PM ET. BBL 3010280024.