9 floors · 117 apartments · 86,360 sq ft · built 2004 · class HR · owner of record: Bh Tilden Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 57 days | Keep the report on file (not filed with DOB) |
| Energy audit and retro-commissioning (2026) Likely applies Local Law 87 · Calendar year 2026 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5136). Agency page | Dec 31, 2026 in 57 days | Due this year |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 57 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 73 days | Annual |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $344,750 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 109 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 86,360 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 178 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 178 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 301 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 17 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 422 days | Next cycle year 2027 |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-09 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 20, 2026 | Construction CLASS - 1 ATOI OBSERVED WHEN ENTERING THE BOILER ROOM A GAS ODER. NATIONAL GRID ARRIVED AND SHUT SERVICE MULTIPLE LEAKS OBSERVED. CONTRARY TO . FGC 406.4 - GAS PIPING SYSTEMS SHALL BE GASTIGHT AND FREE FROM LEAKS, REPAIR #39208562H | Jan 6, 2027 PENDING | $2,500 |
| Oct 20, 2026 | Boilers CLASS - 2 #2 LOCHINVAR HOT WATER BOILER HAS A DEFECTIVE FLOW SWITCH+HW STORAGE TANK#2 IS LEAKING WATER;CORRECT VIOLATION+SUBMIT CERTIFICATE OF CORRECTION #39208466H | Jan 6, 2027 PENDING | $1,250 |
| Oct 20, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, I OBSERVED AT PREMISES, LACK OF FIRESTOPPING AND NON-APPROVED FIREPROOFING MATERIAL THROUGHOUT BUILDING. CONDITIONS ARE HAZARDS FOR RESIDENTS IN THE EVENT OF A FIRE; OPEN GAPS CAUSE POSSI #39208751R | Jan 6, 2027 PENDING | $2,500 |
| Oct 20, 2026 | Elevators CLASS - 2 CLASS 2: HOIST ROPES LACK PROPER LUBRICATION; EXCESSIVE RED-COLORED ROPE RESIDUE (ROUGE) OBSERVED ON THE ROPES AND TOP OF CAR, AS PER ASME A17.1/CSA B44 8.6.4.1. REMEDY: CLEAN AFFECTED AREAS, INSPECT HOIST ROPE #39208614K | Jan 6, 2027 PENDING | $625 |
| Oct 20, 2026 | Construction CLASS - 1 ATOI OBSERVED IN THE BASEMENT OBSTRUCTED/PAINTED SPRINKLER CAPS TO THE CEILING. THIS IS CONTRARY TO BC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKLERS BE POSITIONED #39208561X | Jan 6, 2027 PENDING | $2,500 |
| Oct 20, 2026 | Elevators CLASS - 2 CLASS 2: HOIST ROPES LACK PROPER LUBRICATION; EXCESSIVE RED-COLORED ROPE RESIDUE (ROUGE) OBSERVED ON THE ROPES AND TOP OF CAR, AS PER ASME A17.1/CSA B44 8.6.4.1. REMEDY: CLEAN AFFECTED AREAS, INSPECT HOIST ROPE #39208615M | Jan 6, 2027 PENDING | $625 |
| Jun 8, 2026 | Unknown CLASS - 1 MISCELLANEOUS CHAPTER 33 VIOLATIONS. ATOI, OBSERVED ONGOING CONSTRUCTION WORK ON ACTIVE PERMIT # B0192827-I1-GC. NOTED UNSAFE STORAGE OF CONSTRUCTION MATERIALS (PALLETS OF BRICKS, MORTAR) AND SCAFFOLDING EQUIPM #39191743Z | Nov 18, 2026 PENDING | $5,000 |
| Nov 21, 2025 | Construction CLASS - 2 OBSERVED SPRINKLER HEADS OBSTRUCTED ON GROUND FLOOR AND BASEMENT. STAIRCASE A FLOORS 2 THROUGH 9 DOORS ARE HITTING STANDPIPE. THE FIRST FLOOR BATHROOM USING PVC WASTE LINE UNDER THE SINK. THE REQUIRED 5 YEAR HY #39167931X | Jan 28, 2026 DEFAULT | $6,250 |
| Nov 14, 2025 | Elevators CLASS - 2 CLASS 2 ITEMS: MISSING YEAR 2025 MAINTENANCE LOG, CONDUCT ROUTINE SERVICE AND UPDATE THE RECORDS. FIRE EXTINGUISHER TEST TAG OUTDATED, PROVIDE SERVICE AND UPDATE THE TAG. PIT LIGHT INOPERATIVE, REPAIR. CLEAN EN #39167004P | Jan 21, 2026 DEFAULT | $3,125 |
| Nov 14, 2025 | Elevators CLASS - 2 CLASS 2 ITEMS: FIRE EXTINGUISHER TEST TAG EXPIRED, PROVIDE SERVICE AND UPDATE THE TAG. EMERGENCY PHONE INOPERATIVE, PROVIDE 2 WAY COMMUNICATION. CLEAN ENTIRE PIT AREA. CAR ROLLER GUIDES NOT FULLY ENGAGE THE RAI #39167003N | Jan 21, 2026 DEFAULT | $3,125 |
| Aug 11, 2025 | Construction CLASS - 1 FAILURE TO SAFEGUARD THE PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT TIME OF INSPECTION, OBSERVED BRICK AND SMALL DEBRIS ON TOP OF ADJACENT PROPERTY 2516 TILDEN AVE. BUILDING ROOF AND YARD. NOTE #39156735P | Oct 23, 2026 DEFAULT | $12,500 |
| Nov 20, 2023 | Construction CLASS - 2 PALATE OF BRICKS STORED ON SIDEWALK SHED., COMPLY TO CODE SPECIFICATIONS #39099811J | Feb 7, 2024 DEFAULT | $5,000 |
| Nov 20, 2023 | Elevators CLASS - 2 CAR DOOR GIBS WORN, REPLACE. HOIST ROPES ROUGHED, MONITOR. LIGHTS INSIDE THE CAR UNGUARDED, PROVIDE GUARD. SIGN ON THE MOTOR ROOM DOOR WORN AND ILLEGIBLE, REPLACE. IN CAR COMMUNICATION INOPERATIVE, REPAIR. CATE #39099709N | Jan 24, 2024 DEFAULT | $3,125 |
| Nov 20, 2023 | Boilers CLASS - 2 RELIEF VALVE ON UNIT 3 OF SLANT FIN CARAVAN BOILER MODEL GGHT1600E IS LEAKING.CORRECT VIOLATING CONDITION & SUBMIT A CERTIFICATED OF CORRECTION. #39099729K | Sep 23, 2024 DEFAULT | $0 |
| Nov 20, 2023 | Elevators CLASS - 2 CAR DOOR GIBS WORN, REPLACE. HOIST ROPES ROUGHED, MONITOR. IN CAR COMMUNICATION INOPERATIVE, REPAIR. CATEGORY 1 TEST PAST DUE (12/20/2021), PERFORM CATEGORY 1 TEST AND PROVIDE AN UPDATED CAT 1 TAG. CATEGORY 5 T #39099708L | Jan 24, 2024 DEFAULT | $3,125 |
| Aug 21, 2023 | Elevators CLASS - 2 REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. REPLACE CAR DOOR GIBS. INOPERATIVE PHONE. ROUGED HOIST ROPES. #39092950H | Oct 25, 2023 DEFAULT | $3,125 |
| Aug 21, 2023 | Elevators CLASS - 2 REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. REPLACE CAR DOOR GIBS. INOPERATIVE PHONE. ROUGED HOIST ROPES. UNGUARDED CAR LIGHTING. #39092951J | Oct 25, 2023 DEFAULT | $3,125 |
| Feb 24, 2023 | Construction CLASS - 2 OBSERVED DEFECTIVE PRESSURE RELIEF VALVE ON THE # 4 BOILER AND ALSO DEFECTIVE SPRINKLER PUMP DISCHARGING WATER ONTO FLOOR. AS PER 102.3 MAINTENANCE. INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL #39080242Z | Jun 26, 2023 IN VIOLATION | $0 |
| Dec 2, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#914251. REMEDY:SUBMIT ACCEPTABLE REQUIR #37024108Z | Aug 7, 2023 DEFAULT | $0 |
| Feb 11, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG FACADE/WALLS&APPURTENANCES.NOTE:ATOIOBSERVED@EXP1,2,3:VERT/STEP CRACKS@SEVERAL LOCATIONS&DAMAGED MORTAR JOINTS.MAINTAIN EXTERIOR BLDG FACADE/WALLS&APPURTENANCES.PROVIDE SAFETY #35640347M | Jun 22, 2022 DEFAULT | $0 |
| Dec 16, 2021 | Construction CLASS - 1 1RCNYMISCRSMISC OWNER FAILED TO REPAIR FACADE W/I RECOD TIME GIVEN BY QEWI.AS NOTED:ATOI DEFECTIVE CONDITION WERE OBSERVED ON EXP1,2,3 CONDITIONS SUCH AS CRACKS&STEP CRACKS DAMAGED MORTAR JOINTS,VERT CRACKS.THE #35640406N | May 4, 2022 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2024 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2401325 | DOB VIOLATION - ACTIVE |
| Aug 2, 2024 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00480 | DOB VIOLATION - ACTIVE |
| Jul 30, 2024 | HAZARDOUS CONDITION (FACADE) CYCLE 9A UNSAFE REPORT FILED #911900 | DOB VIOLATION - ACTIVE |
| May 2, 2024 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00996 | DOB VIOLATION - ACTIVE |
| Mar 16, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00368 | DOB VIOLATION - ACTIVE |
| Feb 22, 2022 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 #01782 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Sep 25, 2026 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 22, 2026 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Mar 6, 2026 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Dec 8, 2025 | GHG Emissions - LL97 FTF-EN-LL97320 | Active |
| Dec 3, 2025 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Sep 26, 2025 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Feb 28, 2025 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Dec 2, 2024 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Dec 1, 2024 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Aug 2, 2024 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jul 30, 2024 | Facades FISPHAZ CYCLE 9A UNSAFE REPORT FILED | Active |
| May 2, 2024 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Mar 16, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2022 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 30, 2026 | C | Apt 9H · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 9H, 9th STORY, 5th APARTMENT FROM WEST AT NORTH | Oct 30, 2026 |
| Oct 26, 2026 | C | Apt 3K · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3K, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 25, 2026 |
| Oct 26, 2026 | C | Apt 3K · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3K, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 25, 2026 |
| May 8, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 11, 2026 |
| Jun 13, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 16, 2025 |
| Apr 16, 2024 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 20, 2024 |
| Mar 30, 2023 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 3, 2023 |
| Sep 26, 2022 | C | Apt 9M · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 9M, 9th STORY, 7th APARTMENT FROM EAST AT SOUTH | Oct 22, 2022 |
| Sep 13, 2022 | C | Apt 9K · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 9K, 9th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 9, 2022 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 30, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 9H, 9th STORY, 5th APARTMENT FROM WEST AT NORTH | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 26, 2026 | HPD C | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3K, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Oct 26, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3K, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Oct 20, 2026 | ECB | Construction: ATOI OBSERVED WHEN ENTERING THE BOILER ROOM A GAS ODER. NATIONAL GRID ARRIVED AND SHUT SERVICE MULTIPLE LEAKS OBSERVED. CONTRARY TO . FGC 406.4 - GAS PIPING SYSTEMS SHALL BE GASTIGHT AND FREE FROM LEAKS, REPAIR | Open |
| Oct 20, 2026 | ECB | Boilers: #2 LOCHINVAR HOT WATER BOILER HAS A DEFECTIVE FLOW SWITCH+HW STORAGE TANK#2 IS LEAKING WATER;CORRECT VIOLATION+SUBMIT CERTIFICATE OF CORRECTION | Open |
| Oct 20, 2026 | ECB | Construction: AT TIME OF INSPECTION, I OBSERVED AT PREMISES, LACK OF FIRESTOPPING AND NON-APPROVED FIREPROOFING MATERIAL THROUGHOUT BUILDING. CONDITIONS ARE HAZARDS FOR RESIDENTS IN THE EVENT OF A FIRE; OPEN GAPS CAUSE POSSI | Open |
| Oct 20, 2026 | ECB | Elevators: CLASS 2: HOIST ROPES LACK PROPER LUBRICATION; EXCESSIVE RED-COLORED ROPE RESIDUE (ROUGE) OBSERVED ON THE ROPES AND TOP OF CAR, AS PER ASME A17.1/CSA B44 8.6.4.1. REMEDY: CLEAN AFFECTED AREAS, INSPECT HOIST ROPE | Open |
| Oct 20, 2026 | ECB | Construction: ATOI OBSERVED IN THE BASEMENT OBSTRUCTED/PAINTED SPRINKLER CAPS TO THE CEILING. THIS IS CONTRARY TO BC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKLERS BE POSITIONED | Open |
| Oct 20, 2026 | ECB | Elevators: CLASS 2: HOIST ROPES LACK PROPER LUBRICATION; EXCESSIVE RED-COLORED ROPE RESIDUE (ROUGE) OBSERVED ON THE ROPES AND TOP OF CAR, AS PER ASME A17.1/CSA B44 8.6.4.1. REMEDY: CLEAN AFFECTED AREAS, INSPECT HOIST ROPE | Open |
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 21, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 9K, 9th STORY, 3rd APARTMENT FROM WEST AT NORTH | Closed |
| Jul 16, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 7E, 7th STORY, 7th APARTMENT FROM WEST AT NORTH | Closed |
| Jul 16, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 7J, 7th STORY, 3rd APARTMENT FROM WEST AT NORTH | Closed |
| Jul 16, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 7 O, 7th STORY, 5th APARTMENT FROM EAST AT SOUTH | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 4, 2026, 9:53 AM ET. BBL 3051360008.