6 floors · 49 apartments · 43,848 sq ft · built 1928 · class D1 · owner of record: 2505 Olinville Avenue Llc D
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 43,848 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-27 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 14, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED THE VIOLATING CONDITION HAS BEEN CORRECTED UNDER JOB #X01192 #39203956H | Nov 20, 2026 PENDING | $1,250 |
| Sep 24, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALL(S)OR APPURTENANCES.NOTE:AT THE TIME OF INSPECTION OBSERVED AT EXPO#1 EAST ELEVATION VERTICAL CRACK ON PARAPET LEVEL AT EXP#4 NORTH ELEVATION DAMAGED BRICK MASONRY/CRAC #35683667L | Nov 29, 2024 ADMIT/IN-VIO | $0 |
| Aug 13, 2024 | Construction CLASS - 1 NOTED DIAGONAL CRACK IN EXP 1 PARAPET WALL, VERTICAL CRACKING ON EXP 1, MISSING COPING ROOF EXP 4, AND DECORATIVE MOULDING MISSING AT 5TH FLOOR EXP 1 AND 2., REPAIR AND/REPLACE; REPAIR CRACKING, ROOF COPING, AN #39121805L | Oct 18, 2024 ADMIT/IN-VIO | $0 |
| Sep 9, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED AT SIX FLOOR APT. 6D CEILING IN A STATE OF DISREPAIR INCLUDING LINEAR CRACKS AND DETACHING CEILING BOARD WITH THE POTENTIAL #39047188M | Oct 29, 2021 ADMIT/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 25, 2026 | B | Apt 4F · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WEST | Jul 30, 2026 |
| Jun 25, 2026 | B | Apt 4F · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WEST | Jul 30, 2026 |
| Jun 4, 2026 | B | Apt 6H · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RUBBER GASKETS AT REFRIGERATOR IN THE KITCHEN LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 9, 2026 |
| May 22, 2026 | C | Apt 6H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 17, 2026 |
| Sep 4, 2025 | A | Apt 2F · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st CLOSET FROM WEST AT NORTH WALL DOOR FRAME, NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST | Dec 8, 2025 |
| Jul 21, 2025 | C | Apt 2F · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE PRESUMED LEAD PAINT THAT IS XRF TESTED INCONCLUSIVE AT 0.5 MG/CM2 (28 RCNY §11-07(B)) FROM REQUIRED WINDOW AND/O | Aug 14, 2025 |
| Jul 21, 2025 | C | Apt 2F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM NORTH AT EAST WALL, SOUTH WALL, WEST WALL IN THE PRIVATE HALLWAY L | Aug 14, 2025 |
| May 21, 2025 | C | Apt 6H · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0, WG TO REPLACE = 2, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 6H, 6th STORY, 2nd APAR | Jun 16, 2025 |
| May 19, 2025 | B | Apt 6H · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GASKET AT REFRIGERATOR DOOR SEAL IN THE KITCHEN LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 23, 2025 |
| May 19, 2025 | B | Apt 6H · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 23, 2025 |
| May 19, 2025 | C | Apt 6H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 14, 2025 |
| May 19, 2025 | B | Apt 6H · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RADIATOR SHUT OFF VALVE IN THE 4th ROOM FROM EAST LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 23, 2025 |
| Jan 2, 2024 | B | Apt 6F · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM SOUTH AT WEST | Feb 6, 2024 |
| Jan 2, 2024 | C | Apt 1H · § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WASH BASIN IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST | Jan 8, 2024 |
| Jan 2, 2024 | B | Apt 6F · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM SOUTH AT WEST | Feb 6, 2024 |
| Dec 29, 2023 | C | Apt 3E · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH A | Jan 22, 2024 |
| May 5, 2022 | B | Apt 6G · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE UNEVEN WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Jun 9, 2022 |
| Apr 4, 2022 | C | Apt 6G · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 30 SQ FT AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 30, 2022 |
| Mar 10, 2022 | B | Apt 6G · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK 0VER CEILINGAND EAST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 14, 2022 |
| Mar 10, 2022 | B | Apt 6G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, NORTH AND SOUTH WALLS IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 14, 2022 |
| Sep 23, 2021 | B | Apt 6G · § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL HOUSEHOLD ITEMS BARRELS AND BOXES IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 28, 2021 |
| Jul 29, 2019 | C | Apt 4G · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 4; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th STORY, 1st APA | Aug 26, 2019 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 14, 2026 | ECB | Construction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED THE VIOLATING CONDITION HAS BEEN CORRECTED UNDER JOB #X01192 | Open |
| Aug 6, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HEAVY DUTY LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 4:36 AM ET. BBL 2044280001.