9 floors · 160,279 sq ft · built 2022 · class HR · owner of record: 25c Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 56 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | Feb 21, 2027 in 108 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 160,279 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 177 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 177 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 787 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2994). Agency page | Dec 31, 2034 in 2978 days | Next due 2034 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 24, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION, OBSERVED INACTIVE JOBSITE WITH BUILDING FOOTPRINT OVER 5,000 SF AND NO WATCHPERSON, CONTRARY TO BC 3303.3. KNOCKED AND CALLED OUT WITH NO RESPONSE. CONTACTED SITE WATCH SECURITY, WHICH AD #39561002R | Jan 6, 2027 PENDING | $2,500 |
| Oct 24, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION, OBSERVED JERSEY BARRIERS OCCUPYING THE ROADWAY AND CONSTRUCTION FENCE OCCUPYING THE SIDEWALK. UPON REVIEW OF DOT RECORDS, NO OCCUPANCY PERMITS WERE FOUND, CONTRARY TO BC 3307.2.1, CREATIN #39561003Z | Jan 6, 2027 PENDING | $2,500 |
| Apr 29, 2026 | Unknown CLASS - 2 DURING MY INSPECTION AND UPON REVIEWING DOB NOW AND BIS SYSTEM REVEALS SSM / SSC ON MULTIPLE PERMITS AND NB NOT IN COMPLIANCE TO CODE BC 3310.5.4 STOP ALL WORK UNDER APPLICATION320625070-01-NB EXCEPT TO UPDATE #39553637K | Mar 1, 2027 | $2,500 |
| Feb 3, 2026 | Construction CLASS - 2 I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOSURE 1&2 CONTRARY TO CODE. MINIMUM 8FT HEIGHT NOT MAINTAINED AT CORNER OF EXPOS 1&2, PIPES SET BELOW 8FT ACROSS PATHWAY (3307.6.4.7 HEIGHT). SHED BRACING AND JERSEY B #39549891Y | Feb 16, 2027 DEFAULT | $2,430 |
| Feb 3, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A SHED INSTALLED AT EXPOSURE 1&2 NOT NO SIDEWALK SHED INFO PANEL INSTALLED CONTRARY TO CODE 3301.9.2 SIDEWALK SHED PARAPET INFORMATION PANEL. I ALSO OBSERVED A CONSTRUCTION FENCE INST #39549886J | Nov 23, 2026 PENDING | $1,250 |
| Feb 3, 2026 | Construction CLASS - 2 UPON INSPECTION OF AN ACTIVE 10 STORY NB CONSTRUCTION SITE I OBSERVED A FENCE INSTALLED AT EXPOS 1&2 NOT CONSTRUCTED OR MAINTAINED ACCORDING TO CODE. INSTALLED VIEWING PANELS WERE NOT 12X12 IN SIZE CONTRARY TO #39549885H | Feb 16, 2027 DEFAULT | $1,030 |
| Feb 3, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1&2 NOT MAINTAINED CONTRARY TO CODE 3307.6.5.1 SAFE CONDITION. UN-PROTECTED BOLTS & TOPS OF KICKERS ALONG SHED PATHWAY (EXPO 1&2), ROTTING MUDSILLS #39549889P | Feb 16, 2027 DEFAULT | $2,430 |
| Feb 3, 2026 | Construction CLASS - 2 I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1&2 AND UPON REVIEW OF APPROVED DRAWINGS IT WAS DETERMINED THE SHED WAS INSTALLED CONTRARY TO THE PLANS. MISSING DOUBLE HEADERS AT ALL SPANS OVER 10FT. INCORRECT CR #39549892X | Feb 16, 2027 DEFAULT | $1,280 |
| Dec 22, 2025 | Unknown CLASS - 2 BC3303.3 WATCHPERSON 10 STORY NEW BUILDING, BUILDING APPROXIMATELY 39,206 SQUARE FEET. SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY. UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALERT WATC #39548366L | Jan 25, 2027 DEFAULT | $5,000 |
| Dec 22, 2025 | Unknown CLASS - 2 BC3314.8.2 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP# 1 3 4 NOT MAINTAINED AS PER CODE. DEBRIS NETTING LOOSE / MISSING NOT SECURELY FASTENED TO THE FACADE. STOP ALL EXTERIOR WORK AND US #39548365J | Jan 25, 2027 DEFAULT | $5,000 |
| Dec 22, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED CONSTRUCTION FENCE INSTALLED AT EXP#1 2 NOT MAINTAINED AS PER CODE. MULTIPLE PIECES OF WOOD PROTRUDING FROM FENCE CONTRARY TO 3307.7.7 CREATING UNSAFE CONDITION FOR PEDESTRIANS #39548367N | Jan 22, 2027 DEFAULT | $2,500 |
| Oct 10, 2025 | Construction CLASS - 2 15 RCNY 20-08 (B) AT TIME OF INSPECTION OBSERVED: ACTIVE JOB SITE, HYDRANT HAS BEEN USED. UPON REQUEST FOR PERMIT, NONE WAS PROVIDED. CREATING UNSAFE CONDITION FOR SAFETY MONITORING AND COMPLIANCE. OBTAIN PERMI #39545826J | Nov 5, 2026 | $1,250 |
| Oct 9, 2025 | Construction CLASS - 2 ON ACTIVE JOBSITE, OBSERVED SECTION OF SIDEWALK SHED REMOVED WHILE EXTERIOR WORK IS STILL BEING PERFORMED. MAKESHIFT OVER HEAD PROTECTION HAS BEEN INSTALLED IN PLACE OF SIDEWALK SHED. STOP ALL EXTERIOR WORK EXP #39545790R | Nov 5, 2026 | $2,400 |
| Oct 9, 2025 | Construction CLASS - 2 ON ACTIVE JOBSITE, OBSERVED CONSTRUCTION FENCE INSTALLED @ EXPO 4 REAR YARD OF JOBSITE. SECTIONS OF THE CONSTRUCTION FENCE ARE MISSING LEADING TO COMMON AREA OF ADJACENT PROPERTY. STOP ALL WORK @ EXPO 4 OF JOBS #39545792K | Nov 5, 2026 | $1,000 |
| Oct 9, 2025 | Unknown CLASS - 2 OBSERVED ADDITIONAL 1 STORY STRUCTURE @ EXPOSURE 4 OF JOBSITE. ADJACENT PROPERTIES @ LEFT HAS NOT BEEN PROVIDED WITH ROOF PROTECTION AND STRUCTURE ON RIGHT HAS NO OVER HEAD PROTECTION PROVIDED AT COMMON AREA. S #39545791Z | Nov 5, 2026 | $5,000 |
| Jul 31, 2025 | Construction CLASS - 2 OBSERVATION: MODEL APARMENTS ON 3RD/4TH FLOOR BEING SHOWN TO PERSPECTIVE BUYERS. APARTMENTS WERE COMPLETELY FURNISHED. TO GET TO MODEL APTS,PERSPECTIVE BUYERS HAS TO WALK THRU A LOBBY UNDER ACTIVE CONSTRUCTION #39543186L | Mar 8, 2027 PENDING | $6,250 |
| May 24, 2025 | Unknown CLASS - 2 NO WATCHPERSON NOTE: ATOI OF A 10-STORY NEW BUILDING 39,209 SQ FT. SITE WAS CLOSED WITH NO CONSTRUCTION ACTIVITY. I SHOUTED AROUND THE PERIMETER AND BANGED ON THE FENCE/DOOR TO ALERT THE WATCHPERSON AND VERIFY #39540640Z | Jan 14, 2027 | $5,000 |
| Feb 28, 2025 | Unknown CLASS - 2 BC3308.6.1.4 AT TIME OF INSPECTION OF 11 STORY NEW BUILDING DURING ACTIVE CONSTRUCTION SITE, UPON INSPECTION OBSERVED INADEQUATE SUPPORTED SCAFFOLD ALTERNATIVE IN LIEU OF HORIZONTAL SAFETY NETTING 3 STORIES BEL #39537461X | Sep 14, 2026 IN VIOLATION | $2,500 |
| Feb 28, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION OF 11 STORY NB THAT INCLUDE APPROXIMATELY 4000 CUBIC YARD OF CONCRETE. UPON REQUEST FOR CONCRETE SAFETY MANAGER NONE WAS PROVIDED AND REVIEW OF SITE SAFETY MANAGER LOGS NONE WAS MENTION OR #39537460Y | Jan 6, 2027 | $2,530 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 24, 2026 | ECB | Unknown: AT TIME OF INSPECTION, OBSERVED INACTIVE JOBSITE WITH BUILDING FOOTPRINT OVER 5,000 SF AND NO WATCHPERSON, CONTRARY TO BC 3303.3. KNOCKED AND CALLED OUT WITH NO RESPONSE. CONTACTED SITE WATCH SECURITY, WHICH AD | Open |
| Oct 24, 2026 | ECB | Unknown: AT TIME OF INSPECTION, OBSERVED JERSEY BARRIERS OCCUPYING THE ROADWAY AND CONSTRUCTION FENCE OCCUPYING THE SIDEWALK. UPON REVIEW OF DOT RECORDS, NO OCCUPANCY PERMITS WERE FOUND, CONTRARY TO BC 3307.2.1, CREATIN | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 5, 2026, 5:34 PM ET. BBL 3029940075.