2 floors · 4 apartments · 2,900 sq ft · built 1901 · class C3 · owner of record: Newtown Capital Realty Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 778 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 16, 2025 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF ACTIVE SITE OBSERVED MISSING/NOT INSTALLED GUARDRAIL SYSTEM BY STAIRWAY ON 1ST FLOOR GOING DOWN TO BASEMENT (APROX 10 FEET DEEP)-WITH WORKERS PERFORMING WORK/WALKING NEXT TO OPEN #39543754K | Jan 8, 2027 | $5,000 |
| Aug 16, 2025 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OBSERVE ACTIVE WORK WITH APROX 10 WORKERS ON SITE ON SATURDAY 8/16/25-WORK WAS BEING PERFORMED ON CARPENTRY , PLASTERING , TILING, SMALL EXCAVATION IN YARD-UPON CHECKING DOB RECORD #39543752R | Jan 8, 2027 | $2,500 |
| Jun 6, 2025 | Unknown CLASS - 1 OBSERVED UNPROTECTED POWER LINES @ EXPO 1,ADJCENT TO PUMP JACK POSTS & STRUCTURAL STEEL DECK, W/ BLUE TARP BLOCKING VIEW OF EXPOSED POWER LINES. 3301.5 :UNSAFE CONDITIONS. ANY STRUCTURE, TEMPORARY CONSTRUCTION #39541161X | Dec 14, 2026 | $5,000 |
| Jun 6, 2025 | Construction CLASS - 1 ACTIVE JOBSITE AFFECTING ADJACENT PROPERTIES @ EXP'S. 2 &4, UNFINISHED EXTERIOR WORK W/ ROOF PROTECTION, NO CONSTRUCTION FENCE @ EXP. 2 & 4 & ACCESSIBLE, NO GUARDRAILS @ OPENINGS/ BALCONIES, FLOORS, NO FIRE PRO #39541154H | May 10, 2027 | $10,000 |
| Jun 6, 2025 | Construction CLASS - 2 ACTIVE JOBSITE WITHOUT SITE SAFETY PLAN REQUIRED ON JOBSITES THAT REQUIRE A CS, PRE CONSTRUCTION SURVEY FOR EXPOSURE O INTERIOR WALL @ EXO2, PUMP JACKS INSTALLED ON ADJACENT PROPERTY DECK WITHOUT NEIGHBOR'S AGR #39541159R | May 10, 2027 | $5,000 |
| Jun 6, 2025 | Unknown CLASS - 2 CONSTRUCTION SUPERINTENDENT(#030455) FAILED TO CORRECT UNSAFE CONDITIONS & DOCUMENT RECORD ON DAILY LOG BOOK, MISSING PROTECTION OF ADJACENT PROPERTIES, NO FENCE, ROOF PROTECTION, GUARDRAILS, EXPOSURE OF FIRE P #39541152Y | May 4, 2027 | $5,000 |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 1988 | CONSTRUCTION #444R1LEGAL | DOB VIOLATION - ACTIVE |
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 11:10 PM ET. BBL 4005740006.