7 floors · 14,686 sq ft · built 1925 · class O6 · owner of record: Hw W 34th St Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 51 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-05-31 (Accepted). Agency page | Dec 31, 2026 in 51 days | 1 of 1 without an accepted 2026 report yet |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $193,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 103 days | No Cycle 10 report on record yet |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1147 days | Next cycle year 2029 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jul 13, 2026 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO DETERIORATED/DAMAGED JOINTS AND/OR LOOSE STONE AT EXP2 W ELEV, 7FL POTENTIAL HAZARD TO PUBLIC & PROPERTY REQUIRING IMMEDIATE COLLECTIVE ACTION. REMEDY:IMMED RETAIN NYS LIC PROF ENG P.E. TO EVALUATE EXISTING CONDITIONS AND DIRECT/SUPERVISE EMERGENCY WORK. (REFER TO VIOLATI #FA0501JW | DOB VIOLATION - ACTIVE |
| Feb 21, 2022 | HAZARDOUS CONDITION (FACADE) CYCLE 9A UNSAFE REPORT FILED #910175 | DOB VIOLATION - ACTIVE |
| May 31, 2018 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 #00156 | DOB VIOLATION - ACTIVE |
| Jan 31, 2013 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012 #00498 | DOB VIOLATION - ACTIVE |
| Nov 30, 2007 | LOCAL LAW 11/98 - FACADE #NRF42522 | DOB VIOLATION - ACTIVE |
| Jul 2, 1997 | CONSTRUCTION #05C1 | VIOLATION UNSERVED ECB-ACTIVE |
| Jul 2, 1997 | CONSTRUCTION #05C1 | DOB VIOLATION - ACTIVE |
| Jul 2, 1997 | CONSTRUCTION #05C01 | DOB VIOLATION - ACTIVE |
| Mar 5, 1997 | ZONING #MTF6RI | DOB VIOLATION - ACTIVE |
| Mar 5, 1997 | CONSTRUCTION #MTF5RI | DOB VIOLATION - ACTIVE |
| Feb 14, 1991 | ELEVATOR #1409B02 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Report | Active |
| Feb 21, 2022 | Facades FISPHAZ CYCLE 9A UNSAFE REPORT FILED | Active |
| May 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 | Active |
| Jan 31, 2013 | Facades FISPNRF FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012 | Active |
| Nov 30, 2007 | Facades LL1198 CYCLE 6 NO REPORT FILED | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 10, 2026, 11:00 AM ET. BBL 1007840015.