2 floors · 46,260 sq ft · built 1914 · class W2 · owner of record: R C Ch Of Holy Innoce
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 46,260 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 167 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 167 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 411 days | Next cycle year 2027 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-30 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 21, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: AT TIME OF INSPECTION THERE WAS NO FIRESTOPPING IN ELECTRIC METER ROOM. REMEDY: PROVIDE/MAINTAIN FIRE STOPPIN #35724835J | Feb 17, 2026 POP/IN-VIO | $0 |
| Jan 21, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANENR. NOTED: INTERIORSMOKE DOORS DO NOT SELF-CLOSE PROPERLY WHEN TESTED. 2ND FLR-"STAIRCASEB". 1ST FLR-"STAIRCASE A", STAIRCASE B", "STAIRCASE D", "GYM DOOR", SM #35724833X | Feb 17, 2026 POP/IN-VIO | $0 |
| Jan 21, 2026 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. NOTED: "EXIT 5" AND "EXIT 4" DO NOT CLOSE WHEN TESTED. REMEDY: REPAIR AND/OR REPLACE DOORS. #35724834H | Feb 17, 2026 POP/IN-VIO | $0 |
| Aug 28, 2025 | Boilers CLASS - 2 PEERLESS BOILER#2 INSTALLED WITH PERMIT310208708NOT SIGNED OFF+GAS PIOLIT NOT HARD PIPE TO REGULATOR+BOILER BLOWDOWN NOT PIPED TO DRAIN+GAS KITCHEN MAKEUP AIR FURNACE>OUTSIDE AIR INTAKE SCREEN 1/2 CLOGGED;CORRE #39158619R | Dec 15, 2025 IN VIOLATION | $0 |
| Aug 28, 2025 | Boilers CLASS - 3 PEERLESS BOILER#1 INSTALLED WITH PERMIT310208708NOT SIGNED OFF+GAS PIOLIT NOT HARD PIPE TO REGULATOR+TEMPORARY LIGHTS IN BOILER ROOM+BOILER BLOWDOWN NOT PIPED TO DRAIN;CORRECT VIOLATION+SUBMIT CERTIFICATE OF CO #39158620Y | Dec 15, 2025 IN VIOLATION | $0 |
| Feb 4, 2025 | Construction CLASS - 2 REISSUE #35672648M; FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: A. T. O. I. @ 2ND FLOOR DOOR IN ROOMS 212, 213, 215, 206 DOES NOTCLOSE PROPERLY WHEN TESTED. REMEDY: REPAIR AND/OR REPLACE. #35688844X | Apr 28, 2025 DEFAULT | $3,125 |
| Jul 23, 2024 | Boilers CLASS - 2 FOUND PEERLESS GAS FIRED BOILER UNREGISTERED. S/N 594770-200803. REGISTER BOILER AND CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION #39119719M | Oct 2, 2024 STIPULATION/IN-VIO | $0 |
| Jul 23, 2024 | Boilers CLASS - 2 FOUND PEERLESS GAS FIRED BOILER UNREGISTERED. S/N: LC-011179-1097. REGISTER BOILER AND CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION #39119720J | Oct 2, 2024 STIPULATION/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 3, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00070 | DOB VIOLATION - ACTIVE |
| Nov 3, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00086 | DOB VIOLATION - ACTIVE |
| Aug 3, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00430 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 14) | Active |
| Feb 3, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Nov 3, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Aug 3, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
None open.