5 floors · 26 apartments · 20,810 sq ft · built 1914 · class C1 · owner of record: 246 Wadsworth Realty Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 50 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 66 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 294 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 415 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-05 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jun 1, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AS PER SECTION 28.301.1 OF THE NYC ADMIN CODE.AS NOTED AT EXP2,OBSERVED VERTICAL BRIC K STEP CRACK,ALSO VERTICAL BRICK STEP CRACK AT EXP4.OBSERVED AT ROOF E LEVATION COUNTLESS HAIRLINE CRACKS ON PARAPET.CRACKING OBSERVED THROUG HOUT BULKHEAD.RE #SR11201BB | DOB VIOLATION - ACTIVE |
| Jul 8, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AS NOTED AT THE TIME OF INSPECTION,I OBSERVED ON EXP 2 SOUTH ELEV:ERODING BRICKS,SPALL ING MORTAR BENEATH COPING TILES AT PARAPET.MULTIPLE CRACKED SILLS ON S EVERAL FLOORS,CRACKS IN BRICK WORK AT MULTIPLE SPANDRELS.EXP3&4 WEST & NORTH ELEV:STEP C #SR1201RF | DOB VIOLATION - ACTIVE |
| Sep 27, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTE: AT TIME OF INSPECTION OBSERVED STEP CRACK AT PARAPET WALL OF EXPOSURE 4 BOWING LINTELS AT EXPOSURE #4 MULTIPLE LEVELS AND SPALLING COATING AT EXPOSURE #2. DAMAGED MISSING/CRACKED COPING STONES. REMEDY: REPAIR AND/OR REPLACE #SR11201DO | DOB VIOLATION - ACTIVE |
| May 17, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED STEP CRACKING, DAMAGED AND MISSING MORTAR JOINTS ON EXPOSURE 4 NORTH ELEVATION. REMEDY: REPAIR AND OR REPLACE #SR11201XN | DOB VIOLATION - ACTIVE |
| Jan 10, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AT THE TIME OF INSPECTION OBSERVED ON EXPOSURE 2 MISSING MOTAR JOINTS AT EXPOSURE 3 STEP CRACK WERE OBSERVED IN MULTIPLE LOCATION AND SPALLING MOTAR JOI JOINTS&@ EXPO# 4 OBSERV.CRACK WIND. SILL & CRACK BRICK&SPALLING MORTAR REMEDY:MAINT.BLDG IN #SR11201DO | DOB VIOLATION - ACTIVE |
| Sep 6, 2023 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AT THE TIME OF INSPECTION OBSERVED ON EXPO#4 NORTH ELEVATION:SAGGING CORRODING METAL LINTELS ON SEVERAL FLOORS;BULGING & DISLODGE BRICKS AT CORRODING METAL LINTEL.ON SEVERAL FLOORS. REMEDY MAINTAIN BUILDING IN A CODE COMPIANT MANNER.MAKE NECESS #SR1201RF | DOB VIOLATION - ACTIVE |
| Feb 14, 2023 | CONSTRUCTION FTM BLDG IN CODE COMPLIANT MANNER. OBSERVED DAMAGED/OPEN MORTAR AT EXP1 1ST FLOOR, EXP4 NORTH ELEV DAMAGED/ERRODED MORTAR JOINTS AND BOWED WINDOW LINTEL. REMEDY: REPAIR AND OR REPLACE #SR1201NS | DOB VIOLATION - ACTIVE |
| Nov 16, 2022 | CONSTRUCTION FTM BLDG IN A CODE COMPLIAN MANNER. OBSERVED DAMAGED/ERRODED MORTAR JOINTS AND INADEQUATE REPAIRS ON EXP4 NORTH ELEV. REMEDY: REPAIR AND/ OR PLACE #SR1201XN | DOB VIOLATION - ACTIVE |
| Aug 2, 2022 | CONSTRUCTION EMERGENCY WORK IRDER DUE TO IMMINENT HAZARDOUS CONDITIONS ON FACADE AT EXPOSURE 1 EAST ELEVATION OVER MAIN ENTRANCE WALK WAY AND SIDEWALK OBSERVED CRACKS, AND STEP CRACKS, BULGING, DISLODGE BRICKS ON SEVERAL FLOORS AT CORRODED SAGGING LINTELS. REMEDY: IMMED REPAIR AND OR REPLACE ALL DAMAGED FACADE B #LL1202RF | DOB VIOLATION - ACTIVE |
| Aug 2, 2022 | CONSTRUCTION FTM BLDG IN CODE COMPLIANT MANNER. OBSERVED ON EXP1 EAST ELEV: DAMAGED, CRACKED MORTAR JOINTS AT SEVERAL CORRODED METAL LINTELS AT SEVERAL FLOORS OVER MAIN ENTRANCE WALKWWAY. REMEDY: REPAIR AND/OR REPLACE #LL1201RF | DOB VIOLATION - ACTIVE |
| Aug 14, 2021 | CONSTRUCTION FTM BLDG IN A CODE COMPLIANT MANNER. EXP1 EAST ELEVATION EXTERIOR WALL DISPLAYS SUBSTANIAL CRACKS AT PARAPET WALL LEVEL AND DEGRADED MORTAR AND LINTELS AT TOP FLOOR WINDOWS. REMEDY: MAINTAIN BLDG IN A CODE COMPLIANT MANNER. TAKE AND PROVIDE SAFETY MEASURES #LL1201RF | DOB VIOLATION - ACTIVE |
| Aug 3, 2021 | CONSTRUCTION FAILIRE TO COMPLY WITH COMMISSIONER'S ORDER 313183(052620CLLF02AV) ISSUED ON 05/29/2020. AS OF 08/03/2021 OWNER HAS NOT COMPLIED WITH IMMEDIATE CURE ORDER. REMEDY: IMMED COMPLY WITH CODE AND COMMISSIONER'S ORDERS #LL0303SR | DOB VIOLATION - ACTIVE |
| Jul 30, 2021 | CONSTRUCTION FTM BUILDING EXTERIOR WALLS OR APPURTENANCES. AT TIME OF INSPECTION OBSERVED AT EXP 1, EAST ELEV.(WADSWORTH AVE), BRICK-MASONRY SECTION ABOUTH 5FL SEPERATING FROM STRUCTURE. CRACKED MASONRY SECTION AT 5FL LEVEL. LOOSE BRICKS AND OPEN BRICK JOINTS AT 5FL. SEVERELY BENDED- CORROED WINDOW LINELS. REMED #FA1202MB | DOB VIOLATION - ACTIVE |
| May 29, 2020 | CONSTRUCTION FAILURE TO MAINTAIN EXTERIOR MASONRY FACADE AND APPURTENANCES. AT TIME OF INSPECTION MASONRY FACADE OBSERVE DEFECTS AT MULTIPLE LOCATIONS REMEDY: MAINTAIN EXTERIOR MASONRY FACADES AND APPURTENANCES, PROVIDE AND MAINTAIN SAFETY MEASURES, REPAIR DAMAGED FACADE, COMPLY WITH CODE #LLF02AV | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 19, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT SKY LIGHT AT PUBLIC HALL, 5th STORY | Sep 23, 2026 |
| Aug 19, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH | Nov 22, 2026 |
| Aug 19, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT SKY LIGHT AT PUBLIC HALL, 5th STORY | Nov 22, 2026 |
| Aug 19, 2026 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE THE CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH | Sep 23, 2026 |
| Aug 19, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIAL AT CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH | Sep 23, 2026 |
| Aug 19, 2026 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT SKY LIGHT AT PUBLIC HALL, 5th STORY | Sep 23, 2026 |
| Jul 31, 2026 | B | Apt 5C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18752892 ISSUED 01-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE | Sep 4, 2026 |
| Jul 13, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE FOYER LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 17, 2026 |
| Jul 13, 2026 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT PUBLIC HALL, 5th STORY | Aug 17, 2026 |
| Jul 13, 2026 | B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL AND CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH | Aug 17, 2026 |
| Jul 13, 2026 | B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILINGS AT 1st PUBLIC HALL BULKHEAD FROM NORTH | Aug 17, 2026 |
| Jul 13, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 5th STORY | Aug 17, 2026 |
| Jul 13, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 17, 2026 |
| Jul 13, 2026 | B | Apt 5B · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT THE CEILING AND SOUTH WALL IN THE KITCHEN LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 17, 2026 |
| Jul 13, 2026 | B | Apt 5B · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES IN THE WALLS AND CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 17, 2026 |
| Jul 13, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE FOYER LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 17, 2026 |
| Jul 13, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILINGS IN THE 3rd ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 17, 2026 |
| May 26, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS AT BULKHEAD, ROOF | Aug 29, 2026 |
| May 26, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE FOYER LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 30, 2026 |
| May 26, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 30, 2026 |
| May 26, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND ALL WALLS AT BULKHEAD, ROOF | Jun 30, 2026 |
| May 26, 2026 | B | Apt 5B · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH/BASIN IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 30, 2026 |
| May 26, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 30, 2026 |
| May 26, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 30, 2026 |
| May 26, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE FOYER LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 30, 2026 |
| May 26, 2026 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT BULKHEAD AREA, ROOF | Jun 30, 2026 |
| Apr 2, 2026 | B | Apt 5C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | May 7, 2026 |
| Mar 5, 2026 | A | Apt 5B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS IN THE KITCHEN LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 8, 2026 |
| Mar 5, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Apr 9, 2026 |
| Mar 5, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Apr 9, 2026 |
| Mar 5, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST AND SOUTH WALLS IN THE 2nd ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Apr 9, 2026 |
| Mar 5, 2026 | C | Apt 5B · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Mar 19, 2026 |
| Mar 5, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 4th ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Apr 9, 2026 |
| Mar 5, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Apr 9, 2026 |
| Mar 5, 2026 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT 1st PUBLIC HALL BULKHEAD FROM EAST AT SOUTH, 5th STORY | Apr 9, 2026 |
| Mar 5, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT 1st PUBLIC HALL BULKHEAD FROM EAST AT SOUTH, 5th STORY | Apr 9, 2026 |
| Mar 5, 2026 | B | Apt 5B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Apr 9, 2026 |
| Mar 5, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS AT 1st PUBLIC HALL BULKHEAD FROM EAST AT SOUTH, 5th STORY | Jun 8, 2026 |
| Feb 9, 2026 | C | Apt 5C · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 9, 2026 |
| Sep 3, 2024 | C | Apt 2C · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH A | Sep 27, 2024 |
| Aug 30, 2024 | B | Apt 2C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, THE EAST WALL AND THE SOUTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 4, 2024 |
| Aug 30, 2024 | C | Apt 2C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 25, 2024 |
| Aug 30, 2024 | B | Apt 2C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 5th ROOM FROM EAST LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 4, 2024 |
| Aug 30, 2024 | B | Apt 2C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 4th ROOM FROM EAST LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 4, 2024 |
| Aug 30, 2024 | B | Apt 2C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 4, 2024 |
| Jun 13, 2024 | B | Apt 3C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 10 SQFT OF MOLD AT WEST WALL IN THE BATHROOM LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 18, 2024 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 19, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT SKY LIGHT AT PUBLIC HALL, 5th STORY | Open |
| Aug 19, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH | Open |
| Aug 19, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT SKY LIGHT AT PUBLIC HALL, 5th STORY | Open |
| Aug 19, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE THE CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH | Open |
| Aug 19, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIAL AT CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH | Open |
| Aug 19, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT SKY LIGHT AT PUBLIC HALL, 5th STORY | Open |
| Jul 31, 2026 | HPD B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18752892 ISSUED 01-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 11, 2026, 11:18 AM ET. BBL 1021670071.