Brooklyn · Block 6919 · Lot 1 · 11214

2475 West 16 Street

19 floors · 364 apartments · 421,800 sq ft · built 1963 · class D4 · owner of record: Harway Terrace Inc

56open violations
$0ECB/OATH penalties owed
7HPD class C (immediately hazardous)
51dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 51 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 51 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 67 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $3,495,840 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 103 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 421,800 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 172 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 172 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 295 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1147 days
Next cycle year 2029
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6919). Agency page

Dec 31, 2029
in 1147 days
Next due 2029
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-06 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Oct 30, 2024Unknown CLASS - 2
EXPIRED SIDEWALK SHED PERMIT. AS NOTED: AT THE TIME OF INSPECTION SIDEWALK SHED PERMIT WAS EXPIRED. REMEDY: RENEW PERMIT.
#35686579P
Jan 8, 2025
STIPULATION/IN-VIO
$0
DOB (12)
IssuedViolationStatus
Oct 30, 2024CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AS NOTED: AT TH TIME OF INSPECTION ON EXP #1 OBJECTS SITTING ON BALCONY RAILS AT MULTIPLE BALCONIES. OBJECTS ON BALCONY RAILS APPEARS TO BE FAKE OWLS REMEDY: REPAIR AND/OR REPLACE ALL DAMAGED FACADE AND APPURTENANCES
#SR1302RF
DOB VIOLATION - ACTIVE
Oct 18, 2018CONSTRUCTION
STOIP ALL WORK EXCEPT TO MAKE SITE SAFE
#1303GB
DOB VIOLATION - ACTIVE
Oct 18, 2018CONSTRUCTION
STOP ALL WORK EXCEPT TO MAKE SITE SAFE
#1302GB
DOB VIOLATION - ACTIVE
Oct 18, 2018CONSTRUCTION
STOP ALL WORK EXCEPT TO MAKE SITE SAFE
#1301GB
DOB VIOLATION - ACTIVE
Oct 18, 2018CONSTRUCTION
STOP ALL WORK EXCEPT TO MAKE SITE SAFE
#1304GB
DOB VIOLATION - ACTIVE
Feb 21, 2017FACADE SAFETY PROGRAM

#HAZ86798
DOB VIOLATION - ACTIVE
Feb 21, 2017FACADE SAFETY PROGRAM

#HAZ86799
DOB VIOLATION - ACTIVE
Feb 5, 2015FACADE SAFETY PROGRAM

#HAZ75468
DOB VIOLATION - ACTIVE
Feb 5, 2015FACADE SAFETY PROGRAM

#HAZ75467
DOB VIOLATION - ACTIVE
Jan 31, 2013NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012
#01221
DOB VIOLATION - ACTIVE
Jan 31, 2013NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012
#01220
DOB VIOLATION - ACTIVE
Oct 12, 2000CONSTRUCTION

#HTF04YC
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Feb 21, 2017Facades FISP
CYCLE 8A UNSAFE REPORT FILED
Active
Feb 21, 2017Facades FISP
CYCLE 8A UNSAFE REPORT FILED
Active
Feb 5, 2015Facades FISP
CYCLE 7A UNSAFE REPORT FILED
Active
Feb 5, 2015Facades FISP
CYCLE 7A UNSAFE REPORT FILED
Active
Jan 31, 2013Facades FISPNRF
FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012
Active
Jan 31, 2013Facades FISPNRF
FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012
Active
HPD (35) · C 7 · B 25 · A 3
IssuedClassViolationCorrect by
Oct 6, 2025CApt 4K · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4K, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTOct 6, 2025
Feb 24, 2025CApt 19K · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 19K, 19th STORY, 2nd APARTMENT FROM EAST AT SOUTHMar 10, 2025
Feb 18, 2025CApt 19K · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 19K, 19th STORY, 2nd APARTMENT FROM EAST AT SOUTHFeb 18, 2025
Dec 4, 2024CApt 19K · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 19K, 19th STORY, 2nd APARTMENT FROM NORTH AT EASTDec 30, 2024
Nov 7, 2024BApt 16D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN BASE CABINET AT NORTH WALL IN THE KITCHEN LOCATED AT APT 16D, 16th STORY, 1st APARTMENT FROM NORTH AT EASTDec 12, 2024
Nov 7, 2024BApt 16D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN SINK CABINET IN THE KITCHEN LOCATED AT APT 16D, 16th STORY, 1st APARTMENT FROM NORTH AT EASTDec 12, 2024
Nov 7, 2024CApt 16D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 16D, 16th STORY, 1st APARTMENT FROM NORTH AT EASTDec 3, 2024
Aug 30, 2024BApt 10E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 10E, 10th STORY, 2nd APARTMENT FROM WEST AT NORTHOct 4, 2024
Jul 17, 2024BApt 13C · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 13C, 13th STORY, 1st APARTMENT FROM SOUTH AT WESTAug 21, 2024
Aug 14, 2023AApt 16F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 16F, 16th STORY, 1st APARTMENT FROM SOUTH AT WESTNov 17, 2023
Aug 14, 2023AApt 16F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE KITCHEN LOCATED AT APT 16F, 16th STORY, 1st APARTMENT FROM SOUTH AT WESTNov 17, 2023
Aug 14, 2023AApt 16F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 16F, 16th STORY, 1st APARTMENT FROM SOUTH AT WESTNov 17, 2023
Jun 29, 2023BApt 16F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT APT 16F, 16th STORY, 3rd APARTMENT FROM WEST AT NORTHAug 3, 2023
Jun 29, 2023BApt 16F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE KITCHEN LOCATED AT APT 16F, 16th STORY, 3rd APARTMENT FROM WEST AT NORTHAug 3, 2023
Jun 21, 2023BApt 13C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 16 SQ FT AT CEILING, AND ALL WALLS IN THE FOYER LOCATED AT APT 13C, 13th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 26, 2023
Jun 21, 2023BApt 13C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE FOYER LOCATED AT APT 13C, 13th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 26, 2023
Jun 21, 2023BApt 13C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 13C, 13th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 26, 2023
Jun 21, 2023BApt 13C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st BATHROOM LOCATED AT APT 13C, 13th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 26, 2023
Jun 21, 2023BApt 13C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE FOYER LOCATED AT APT 13C, 13th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 26, 2023
Jun 13, 2023BApt 16F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE KITCHEN LOCATED AT APT 16F, 16th STORY, 3rd APARTMENT FROM WEST AT NORTHJul 18, 2023
Jun 13, 2023BApt 16F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 16F, 16th STORY, 3rd APARTMENT FROM WEST AT NORTHJul 18, 2023
Jun 13, 2023BApt 16F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 16F, 16th STORY, 3rd APARTMENT FROM WEST AT NORTHJul 18, 2023
Jun 13, 2023BApt 16F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE KITCHEN LOCATED AT APT 16F, 16th STORY, 3rd APARTMENT FROM WEST AT NORTHJul 18, 2023
Jun 6, 2023BApt 2H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 2H, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJul 11, 2023
Apr 5, 2023CApt 2H · § 27-2005, 2007 HMC: REMOVE THE ILLEGAL DOUBLE CYLINDER KEY OPERATED LOCKING DEVICE AT DOOR , IN THE ENTRANCE LOCATED AT APT 2H, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTApr 11, 2023
Apr 5, 2023CApt 3H · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN DRAIN IN THE TERRACE LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTApr 11, 2023
Apr 5, 2023BApt 19C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 19C, 19th STORY, 1st APARTMENT FROM WEST AT NORTHMay 10, 2023
Apr 5, 2023BApt 19C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 19C, 19th STORY, 1st APARTMENT FROM WEST AT NORTHMay 10, 2023
Apr 5, 2023BApt 19C · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 19C, 19th STORY, 1st APARTMENT FROM WEST AT NORTHMay 10, 2023
Apr 5, 2023BApt 19C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 19C, 19th STORY, 1st APARTMENT FROM WEST AT NORTHMay 10, 2023
Apr 5, 2023BApt 19B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 19B, 19th STORY, 4th APARTMENT FROM SOUTH AT WESTMay 10, 2023
Apr 5, 2023BApt 19C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 19C, 19th STORY, 1st APARTMENT FROM WEST AT NORTHMay 10, 2023
Mar 15, 2019BApt 6E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX.10 SQUARE FEET IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHApr 19, 2019
Nov 12, 2014BApt 19B · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... EAST WALL 3 SQ.FT. CEILING 3 SQ.FT. AT BATHTUB IN THE BATHROOM LOCATED AT APT 19B, 19th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT WESTDec 17, 2014
May 21, 2012BApt 19C · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT SOUTH WALL APROX = 6 SQ FT IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 19C, 19th STORY, 1st APARTMENT FROM WEST AT NORTHJun 25, 2012

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 10, 2026, 6:00 PM ET. BBL 3069190001.

Look up another building