Brooklyn · Block 2421 · Lot 35 · 11211

247 South 3 Street

6 floors · 29 apartments · 21,744 sq ft · built 1915 · class D9 · owner of record: Grower-Green Housing Development Fund Co Rporation

68open violations
$8,125ECB/OATH penalties owed
5HPD class C (immediately hazardous)
46dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 46 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 46 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-03-14 (Accepted). Agency page

Dec 31, 2026
in 46 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 62 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 290 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 777 days
Next cycle year 2028

Open violations

ECB / OATH (15) · $8,125 owed
IssuedViolationHearingBalance
Jul 29, 2026Elevators CLASS - 2
CAB MIRROR ON WRONG SIDE (BC 3001.6.). INOPERATIVE PHONE. (2.27.1.1.3.). BRAKE MAINTENANCE TAG HAS TWO DIFFERENT DATES (8.4.6.4.). MAIN LINE MISSING CONTRACTOR STICKER.
#39198189M
Oct 14, 2026
IN VIOLATION
$625
Sep 26, 2024Elevators CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE AND CONTACT THE DOB ELEVATOR DIVISION AT ELEVATORIR@BUILDINGS.NYC.GOV
#39125890N
Dec 4, 2024
IN VIOLATION
$1,250
Aug 5, 2024Elevators CLASS - 1
1) THE ONLY ELEVATOR IN SECTION OF BUILDING OR BUILDING IS OUT-OF-SERVICE. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT-OF-SERVICE CREATING A HAZARDOUS CONDITION AS PER 1RCNY 11-02. RESTORE TO SERVICE IMMEDIAT
#39120857Z
Oct 9, 2024
IN VIOLATION
$3,125
May 10, 2023Elevators CLASS - 1
CLASS 2 ITEMS: IN CAR COMMUNICATION INOPERATIVE, REPAIR. CAR FLOOR TO LANDING SILL MISALIGNED, ADJUST. CLASS 1 ITEM: DOOR LOCK MONITORING NOT INSTALLED ON THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 O
#39085958R
Jul 19, 2023
IN VIOLATION
$1,250
Oct 26, 2022Elevators CLASS - 1
CLASS 2: REPAIR IN-CAR EMERGENCY PHONE., REPAIR 6TH FLOOR POSITION INDICATOR., CLASS 1: NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CO
#39072758J
Mar 1, 2023
IN VIOLATION
$1,250
Jul 28, 2022Elevators CLASS - 1
DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMANS' SERVICE PRESENT IN CONTROLLER. INSTALL FIREMANS' SERVICE SO DLM IS IN COMPLIANCE WITH SECTION 3.10.12 OF APPENDIX K3. REPLACE JUMPED FUSES ON CONTROLLER. RE
#39066866X
May 15, 2023
IN VIOLATION
$625
Apr 20, 2022Elevators CLASS - 1
CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR. CLASS 1 ITEM: MISSING DLM AS NOW REQUIRED BY CODE. CLASS 2 ITEMS: INOPERATIVE CAR PHONE. REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. MISSING PIT L
#39060638R
Aug 24, 2022
IN VIOLATION
$0
Mar 15, 2022Elevators CLASS - 1
NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. FILE APPLICATION INSTALL DLM AND PERFOR
#39058124R
Aug 17, 2022
IN VIOLATION
$0
Dec 2, 2021Elevators CLASS - 1
1 . NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION, INSTALL D
#39052087J
May 11, 2022
IN VIOLATION
$0
Aug 20, 2021Elevators CLASS - 1
1) NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION, INSTALL DL
#39046398X
Dec 22, 2021
IN VIOLATION
$0
Mar 9, 2021Elevators CLASS - 1
NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION,INSTALL DLM AN
#39037348N
Jan 14, 2022
IN VIOLATION
$0
Dec 24, 2020Elevators CLASS - 1
CLASS 1 : NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. FILE APPLICATION, INSTALL DLM
#39033932Y
May 26, 2021
IN VIOLATION
$0
May 30, 2019Elevators CLASS - 1
05A10/05B01/26D07/32I11/34M07/39L11/67X10/CU-05A;REPAIR & REORDER OPERATIVE THE DOOR ZONE ZONE LACK/05B;ADJUST & REDUCE GAP ON CAR DOOR ON RETURN SIDE WHEN CAR DOOR IS CLOSED/26D;SECURE PROPERLY & PROVIDE CODE
#38267591K
Sep 16, 2019
IN VIOLATION
$0
Jan 17, 2012Elevators CLASS - 2
15I11,16H11,17H11,21M07,39I10,39Q03,42D06,67M07,71Q07,77B07,77Q03- 16H11-MO ROLLER ON 4TH FLOOR WORN, 17H11-1ST FLOOR DOOR 61B5 WORN, 21M07-INTERLOCK COVER ON FLOORS 3,4 MISSING, 39I10- OUTRIGGER BENT, 39Q03
#38219294H
Mar 5, 2012
STIPULATION/IN-VIO
$0
May 17, 2000Local Law Non-Hazardous
FAILURE TO FILE A REPORT OF COMPLIANCE W/LL16/84 CERTIFING TO THE INSTALLATION OF REQUIRED FIRE PROTECTION SYSTEMS-REMEDY:FILE REPORT
#34239569K
Jul 11, 2000
WRITTEN OFF
$0
DOB (12)
IssuedViolationStatus
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01641
DOB VIOLATION - ACTIVE
Jun 30, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00168
DOB VIOLATION - ACTIVE
Jun 5, 2023CONSTRUCTION
AT TIME OF INSPECTION, OBSERVED CHAIN LINK FENCE IN THE SIDE YARD OF THE PROPERTY EXPOSURE #2 IN A STATE OF DISREPAIR LINE POLE, POST & CHAIN LINK BENT AND PUSHING ONTO THE BUILDING ALSO 5TH FLOOR APT 5E KITCHEN WINDOW GLASS PANE BROKEN, DAMAGES TO FENCE AND WINDOW DUE TO ADJACENT PROPERTY 245 S 3RD
#23-01786
DOB VIOLATION - ACTIVE
Mar 2, 2022FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00299
DOB VIOLATION - ACTIVE
Nov 10, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00343
DOB VIOLATION - ACTIVE
Jun 9, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00332
DOB VIOLATION - ACTIVE
Mar 24, 2021ELEVATOR
CEASE USE
#9027H699971
DOB VIOLATION - ACTIVE
Mar 17, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00222
DOB VIOLATION - ACTIVE
Aug 22, 2019FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00374
DOB VIOLATION - ACTIVE
Feb 25, 2019ELEVATOR

#9027/646238
DOB VIOLATION - ACTIVE
Jan 26, 2018(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
#05437
DOB VIOLATION - ACTIVE
Jan 3, 2017(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
#05595
DOB VIOLATION - ACTIVE
DOB NOW Safety (20)
IssuedViolationStatus
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Jun 30, 2023AEUHAZ FTC-AEU-HAZ
Active
Mar 2, 2022AEUHAZ FTC-AEU-HAZ
Active
Nov 10, 2021AEUHAZ FTC-AEU-HAZ
Active
Jun 9, 2021AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2021AEUHAZ FTC-AEU-HAZ
Active
Aug 22, 2019AEUHAZ FTC-AEU-HAZ
Active
Jan 26, 2018Elevators ACC1
Active
Jan 3, 2017Elevators ACC1
Active
HPD (21) · C 5 · B 10 · A 6
IssuedClassViolationCorrect by
May 21, 2025CApt 4D · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOUSEHOLD ITEMS OBSTRUCTING EGRESS AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTHMay 27, 2025
May 5, 2025AApt 5E · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM WEST AT NORTHAug 8, 2025
May 5, 2025AApt 6E · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM WEST AT NORTHAug 8, 2025
May 5, 2025BApt 5E · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB AT WASTELINE IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM WEST AT NORTHJun 9, 2025
May 5, 2025AApt 5E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SILICONE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM WEST AT NORTHAug 8, 2025
May 5, 2025AApt 4B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE AT BATHTUB IN THE BATHROOM LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTHAug 8, 2025
May 5, 2025AApt 5E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM WEST AT NORTHAug 8, 2025
May 5, 2025BApt 4B · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTHJun 9, 2025
Jul 21, 2023AApt 6E · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS, CEILINGS, DOORS, AND DOOR FRAMES IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM WEST AT NORTHOct 24, 2023
Apr 18, 2022BApt 3B · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTHMay 23, 2022
Apr 18, 2022CApt 3B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTHMay 14, 2022
Apr 18, 2022CApt 3B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTHMay 14, 2022
Apr 18, 2022BApt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING & NORTH WALL IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTHMay 23, 2022
Apr 5, 2022BApt 3B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 1 SQ FT AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 14703759 ISSUED 04-DEC-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.May 10, 2022
Dec 6, 2021BApt 3B · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT WASHBASIN IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHJan 10, 2022
Dec 6, 2021BApt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHJan 10, 2022
Dec 6, 2021CApt 3B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHJan 1, 2022
Dec 6, 2021CApt 3B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHJan 1, 2022
Dec 6, 2021BApt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHJan 10, 2022
Dec 6, 2021BApt 3B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHJan 10, 2022
Nov 30, 2021BApt 3B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND NOTH WALL, APPROX. 3 SQ FT IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 14469666 ISSUED 29-JUL-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CJan 4, 2022

Issued in the last 120 days

DateSourceWhatNow
Jul 29, 2026ECBElevators: CAB MIRROR ON WRONG SIDE (BC 3001.6.). INOPERATIVE PHONE. (2.27.1.1.3.). BRAKE MAINTENANCE TAG HAS TWO DIFFERENT DATES (8.4.6.4.). MAIN LINE MISSING CONTRACTOR STICKER.Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 15, 2026, 6:19 AM ET. BBL 3024210035.