6 floors · 54 apartments · 44,766 sq ft · built 1930 · class D1 · owner of record: 245 96th Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 69 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 85 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 44,766 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 190 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 190 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 800 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-25 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Aug 2, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #01465 | DOB VIOLATION - ACTIVE |
| May 2, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #02678 | DOB VIOLATION - ACTIVE |
| Mar 31, 2014 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST #04045 | DOB VIOLATION - ACTIVE |
| Dec 27, 2012 | ELEVATOR #459389 | DOB VIOLATION - ACTIVE |
| Oct 1, 2012 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST #03261 | DOB VIOLATION - ACTIVE |
| Oct 8, 2010 | ELEVATOR ANNUAL INSPECTION / TEST #04389 | DOB VIOLATION - ACTIVE |
| Jun 28, 1993 | LOCAL LAW 10/81 - ELEVATOR 1 #03557 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Aug 2, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 2, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Mar 31, 2014 | Elevators EVCAT1 | Active |
| Oct 1, 2012 | Elevators EVCAT1 | Active |
| Oct 8, 2010 | Elevators VCAT1 | Active |
| Jun 28, 1993 | Elevators LL1081 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 2, 2014 | B | Apt E9 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRIC LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT E9, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2014 |
| Jan 2, 2014 | B | Apt E9 · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT SOUTH WALL APROX = 4 SQ FT IN THE BATHROOM LOCATED AT APT E9, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2014 |
| Jan 2, 2014 | B | Apt E9 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT E9, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2014 |
| Jan 2, 2014 | C | Apt E9 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT E9, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 10, 2014 |
| Jan 2, 2014 | B | Apt E9 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE BATHROOM LOCATED AT APT E9, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2014 |
| Jan 2, 2014 | B | Apt E9 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD CASING AT WINDOW EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT E9, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2014 |
| Jan 2, 2014 | B | Apt E · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AND MILDEW AT EAST WALL AND SOUTH WOOD WINDOW FRAME IN THE 1st ROOM FROM EAST LOCATED AT APT E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2014 |
| Jan 2, 2014 | B | Apt E · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2014 |
| Jan 2, 2014 | B | Apt E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE AT WEST WALL IN THE BATHROOM LOCATED AT APT E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2014 |
| Jan 2, 2014 | B | Apt E · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT AT CEILING IN THE 3rd LIVING ROOM FROM EAST LOCATED AT APT E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2014 |
| Jan 2, 2014 | B | Apt E · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE 3rd LIVING ROOM FROM EAST LOCATED AT APT E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2014 |
| Jan 2, 2014 | B | Apt E · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT WALLS AND CEILING IN THE BATHROOM LOCATED AT APT E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 6, 2014 |
| Oct 2, 2013 | B | Apt E9 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT E9, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 6, 2013 |
| Jan 21, 2009 | B | Apt C7 · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT C7, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Feb 25, 2009 |
| Apr 22, 2008 | B | Apt F6 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE BATHROOM LOCATED AT APT F6, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | May 27, 2008 |
| Apr 22, 2008 | B | Apt F6 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WALL CABINET DOORS IN THE KITCHEN LOCATED AT APT F6, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | May 27, 2008 |
| Apr 22, 2008 | B | Apt F6 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT F6, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | May 27, 2008 |
| Apr 22, 2008 | B | Apt F6 · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT F6, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | May 27, 2008 |
| Apr 22, 2008 | B | Apt F6 · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... MILDEW AT NORTH WALL IN THE BATHROOM LOCATED AT APT F6, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | May 27, 2008 |
| Aug 28, 2007 | B | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING TERRA COTTA COPING AT CUPOLAS ROOF AT SOUTHEAST AND SOUTHWEST | Oct 2, 2007 |
| Aug 28, 2007 | B | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE MARBLE NOSING TO FLOOR DOOR STAIRS BULKHEAD 6 STY PUBLIC HALL TO ROOF | Oct 2, 2007 |
| Aug 28, 2007 | B | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 4 STY WEST APT D6 SCHMIDT | Oct 2, 2007 |
| Aug 28, 2007 | B | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER SOUTHWEST WALL 1 STY PUBLIC HALL | Oct 2, 2007 |
| Aug 28, 2007 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES CEILING AT ENTRANCE TO ELEVATOR CELLAR CENTER | Oct 2, 2007 |
| Aug 28, 2007 | A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CINDER BLOCK WALL ELECTRICAL METER BANK CENTER CELLAR | Dec 1, 2007 |
| Aug 28, 2007 | B | Apt A6 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING, (MS.HARBECK) IN THE ENTIRE APARTMENT LOCATED AT APT A6, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 2, 2007 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 23, 2026, 8:57 PM ET. BBL 3061160041.