Manhattan · Block 1414 · Lot 30 · 10022

244 East 60 Street

5 floors · 18 apartments · 15,910 sq ft · built 1940 · class D4 · owner of record: 244 E 60 St Ownrs Corp

28open violations
$3,750ECB/OATH penalties owed
1HPD class C (immediately hazardous)
44dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 44 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 288 days
Registered through 2027-09-01
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-06 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (5) · $3,750 owed
IssuedViolationHearingBalance
Feb 19, 2026Construction CLASS - 1
NO CERTIFICATE OF CORRECTION ON FILE AS PER COMMISSIONER'S REQUEST FOR CLASS 1 WORK-WITHOUT-PERMIT VIOLATION #39053907K ISSUED 1/6/2022 FOR UNAUTHORIZED GAS WORK, INCLUDING CONNECTION OF THREE GAS-FIRED DRYERS
#39177873X
Apr 30, 2026
IN VIOLATION
$2,500
Jan 6, 2022Construction CLASS - 1
WORK WITHOUT A PERMIT. NOTED: IN CELLAR OF BUILDING UNAUTHORIZED GAS WORK AND CONNECTION OF THREE GAS FIRED DRYERS AND ALSO UNAUTHORIZED EXHAUST CONNECTION., OBTAIN PERMIT
#39053907K
Oct 6, 2022
IN VIOLATION
$0
Jan 6, 2022Construction CLASS - 2
OCCUPANCY CONTRARY TO THAT ALLOWED BY C OF O. NOTED: OBSERVED A LAUNDRY ROOM IN CELLAR CONTRARY TO COFO # 108595 ALLOWING FOR BOILER ROOM, STORAGE AND INCINERATOR ROOM ONLY IN CELLAR, DISCONTINUE ILLEGAL OCCUPA
#39053906Z
Oct 6, 2022
IN VIOLATION
$0
Jan 22, 2020Construction CLASS - 2
PROTECTION INFORMATION PANEL/SIDEWALK SHED PARAPET PANEL/CONSTRUCTION SIGN NOT PROVIDE OR NOT IN COMPLAINCE WITH SECTION.AT TIME OF INSPECITON I OBSERVED SIDEWALK SHED IN PLACE WITHOUT INFORMATION PANEL.REMEDY:
#35467289R
Nov 18, 2021
IN VIOLATION
$625
Jan 22, 2020Construction CLASS - 1
BC3314-SUPPORTED SCAFFOLD NOT TO CODE SPECIFICATIONS.NOTE AT TIME OF INSPECTION I OBSERVED SUPPORTED SCAFFOLD NOT TO CODE (1)NETTING NOT SECURE (2)PLANKS NOT TIED DOWN (3)LOOSE PLANTS THROUGHT.REMEDY:COMPLY WIT
#35467290Y
Nov 18, 2021
IN VIOLATION
$625
DOB (7)
IssuedViolationStatus
Mar 30, 2022FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00032
DOB VIOLATION - ACTIVE
Jan 26, 2018(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
#03601
DOB VIOLATION - ACTIVE
Mar 1, 2013LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
#01759
DOB VIOLATION - ACTIVE
Dec 13, 2011LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
#02281
DOB VIOLATION - ACTIVE
Sep 21, 2010ELEVATOR

#9028/352716
DOB VIOLATION - ACTIVE
Jan 27, 2006CONSTRUCTION

#NE02GA
DOB VIOLATION - ACTIVE
Feb 27, 2001LOCAL LAW 62/91 - BOILERS

#04281
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Mar 30, 2022AEUHAZ FTC-AEU-HAZ
Active
Jan 26, 2018Elevators ACC1
Active
Mar 1, 2013Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
Active
Dec 13, 2011Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
Active
Feb 27, 2001Boiler LL6291
Active
HPD (10) · C 1 · B 6 · A 3
IssuedClassViolationCorrect by
Dec 8, 2021C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF COMMERICAL DRYER IMPROPERLY VENTED AT LAUNDRY ROOMDec 14, 2021
Dec 8, 2021A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT LAUNDRY ROOMMar 13, 2022
Dec 8, 2021A§ 27-2026 ADM CODE PROVIDE A SUITABLE STRAINER FOR THE DRAIN AT ROOF PARPET WALL AT SOUTH ( TOTAL 2 )Mar 13, 2022
Dec 8, 2021B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILINGJan 12, 2022
Dec 8, 2021A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILINGMar 13, 2022
Dec 8, 2021B§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING NEWEL POST CAP ( TOTAL 2 ) AT PUBLIC HALL STAIRS, 2nd STORYJan 12, 2022
Dec 8, 2021B§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT WEST WALL BASEMENT LEVEL AT PUBLIC HALL STAIRSJan 12, 2022
Dec 8, 2021B§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT CEILING AT BOILER ROOMJan 12, 2022
Dec 8, 2021B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT LAUNDRY ROOMJan 12, 2022
May 20, 2014BApt 5B · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM WEST AT NORTHJun 24, 2014

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 5:59 PM ET. BBL 1014140030.