Manhattan · Block 765 · Lot 13 · 10011

243 West 15 Street

5 floors · 22 apartments · 9,920 sq ft · built 1901 · class C4 · owner of record: Noronomo, L.L.C

12open violations
$0ECB/OATH penalties owed
2HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-13 (Accepted). Agency page

Dec 31, 2026
in 47 days
1 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01

Open violations

ECB / OATH (0)

None open.

DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (12) · C 2 · B 8 · A 2
IssuedClassViolationCorrect by
Jun 30, 2023BApt BW · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT SOUTH WALL IN THE BATHROOM LOCATED AT BSMT-APT BW, 1st BSMT-APT FROM SOUTH AT WESTAug 4, 2023
Jun 30, 2023BApt BW · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BW, 1st BSMT-APT FROM SOUTH AT WESTAug 4, 2023
Jun 30, 2023BApt BW · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BW, 1st BSMT-APT FROM SOUTH AT WESTAug 4, 2023
Aug 25, 2021CApt 4RE · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 4RE, 4th STORY, 1st APARTMENT FROM NORTH AT EASTSep 20, 2021
Aug 25, 2021BApt 4RE · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING (8 SQ. FT.) AND NORTH WALL (2 SQ. FT) IN THE BATHROOM LOCATED AT APT 4RE, 4th STORY, 1st APARTMENT FROM NORTH AT EASTSep 29, 2021
Aug 17, 2021B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT 3RD STORY BALCONY AT BUILDING FRONTSep 21, 2021
Aug 12, 2021A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYNov 15, 2021
May 27, 2021A§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET SAFETY COVERS AT EAST WALL AT PUBLIC HALL, 3rd STORYAug 30, 2021
May 28, 2015BApt 4RE · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4RE, 4th STORY, 1st APARTMENT FROM NORTH AT EASTJul 2, 2015
May 28, 2015BApt 4RE · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4RE, 4th STORY, 1st APARTMENT FROM NORTH AT EASTJul 2, 2015
Jul 1, 2008CApt 3RC · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF NO ELECTRICITY 3 STY REAR EAST APT 3RC THROUGHOUT. , SECTION '' ''Jul 7, 2008
Jul 1, 2008BD26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DUMBWAITER NAILED SHUT AT ALL STYS PUBLIC HALL.Aug 5, 2008

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 11:59 AM ET. BBL 1007650013.