Brooklyn · Block 2092 · Lot 66 · 11205

243 Dekalb Avenue

3 floors · 2 apartments · 2,520 sq ft · built 1867 · class S2 · owner of record: 243 Dekalb Ave. Llc

9open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1159dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 307 days
Required only if the owner doesn't live there
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1159 days
Next cycle year 2029

Open violations

ECB / OATH (5)
IssuedViolationHearingBalance
Apr 27, 2019Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING CODE COMPLIANT NOTED: AT THE FRONT, FACADE IS IN DISREPAIR. NUMEROUS SECTIONS OF DECORATIVE STONES ARE DISLOD GED AND SEPARATING WITH PCS BULGING AND IN DANGER OF FALLING TO THE
#35407767H
Feb 10, 2020
IN VIOLATION
$0
Jan 31, 2011Unknown CLASS - 2
50AB 50A-WORK W/O A PERMIT 28-105.1 50B-NO WORK PERMIT FILED W/ DOB FOR THE INSTALLATION OF 3 NEW BOILERS
#32070293P
Jan 25, 2012
IN VIOLATION
$0
Jan 31, 2011Boilers CLASS - 2
36 15 16 32A 50AB 50-FUSIBLE LINK MISSING ON FRESH AIR INTAKE 50B-BOILER ROOM NOT A STORAGE ROOM
#32070292N
Jan 25, 2012
IN VIOLATION
$0
Jan 31, 2011Boilers CLASS - 2
36 15 16 32A 50AB 50A-FUSIBLE LINK FIRE DAMPER MISSING ON FRESH AIR INTAKE 50B-BOILER ROOM NOT A STORAGE ROOM
#32070295Z
Jan 25, 2012
IN VIOLATION
$0
Jan 31, 2011Boilers CLASS - 2
36 15 16 32A 50AB 50A-FUSIBLE LINK FIRE DAMPER MISSING ON FRESH AIR INTAKE 50B-BOILER ROOM HOT A STORAGE ROOM
#32070294R
Jan 25, 2012
IN VIOLATION
$0
DOB (2)
IssuedViolationStatus
Jul 24, 2019FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00406
DOB VIOLATION - ACTIVE
Apr 29, 2019CONSTRUCTION
FTM:STONE FACADE FROM 2FL TO ROOF ALONG DEKALB AVE WAS BULGING INWARDS TOWARDS THE INT'R OF BLDG ALONG THE 3FL&ROOF LEVELS.STONES@PARTY WALLS HAVE SHIFTED OUT OF PLANE WITH CRACKED MORTAR JOINTS.3FL WINDOW SILL PARTY WALL HAD SHIFTED OUT OF PLANE OWN ENGAGE NYSPE TO EVAL ENTIRE BLDG&PREPARE RPR PLAN
#FEU30201PN
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Jul 24, 2019AEUHAZ FTC-AEU-HAZ
Active
HPD (1) · C 0 · B 1 · A 0
IssuedClassViolationCorrect by
Mar 8, 2007BApt 2 · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2, 3rd STORYApr 17, 2007

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 7:48 AM ET. BBL 3020920066.