Bronx · Block 3104 · Lot 7 · 10458

2420 Crotona Avenue

5 floors · 205,250 sq ft · built 1926 · class W1 · owner of record: Nyc Department Of Education

36open violations
$10,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
50dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 50 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 50 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 205,250 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 171 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 171 days
Annual filing
Energy audit and retro-commissioning (2034) Likely applies
Local Law 87 · Calendar year 2034
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3104). Agency page

Dec 31, 2034
in 2972 days
Next due 2034
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-27 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (27) · $10,000 owed
IssuedViolationHearingBalance
May 21, 2026Construction CLASS - 2
REISSUE: 35725299J DATE OF ISSUE: 09/10/2025. EXIT DOOR NOT SELF-CLOSING PROPERLY AT THE TIME OF INSPECTION. AT 1ST FLOOR EXIT-7, OUTSIDE TWO EXIT DOORS. REMEDY: REPAIR OR REPLACE ALL DEFECTIVE EMERGENCY OUTSID
#35731802Z
Jun 12, 2026
POP/IN-VIO
$0
May 21, 2026Construction CLASS - 2
REISSUE #35423346J DATE OF ISSUE: 07/11/2019. FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. AT THE TIME ON INSPECTION OBSERVED AND NOTED AT FRONT OF BUILDING SPALLING AND MISSING MORTAR AT BRICKS THROU
#35731804M
Jun 12, 2026
POP/IN-VIO
$0
May 21, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3; 27-345. AT CELLAR ROOM, ELECTRICAL METER ROOM NO FIRE STOPPING AT WALL AREAS OBSERVED HOLES IN WALLS. REMEDY: PROVIDE/MAINTA
#35731803K
Jun 12, 2026
POP/IN-VIO
$0
May 21, 2026Construction CLASS - 2
REISSUE: 35724625L DATE OF ISSUE: 09/10/2025. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGESAND PUBLIC CORRIDORS PER BC 1006.1; 27-381. AT 4TH FL. NEAR STAIRWAY "
#35731806X
Jun 12, 2026
DEFAULT
$10,000
May 21, 2026Construction CLASS - 2
REISSUE #35724626N DATE OF ISSUE: 09/10/2025. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED OBSERVED AT STAIRCASE "C" BETWEEN 5TH FLOOR AND 4TH FLOOR 8 PANE
#35731801R
Jun 12, 2026
POP/IN-VIO
$0
May 21, 2026Construction CLASS - 2
REISSUE #35724627P DATE OF ISSUE: 09/10/2025. FAILURE TO MAINTAIN BUILDING IN MAINTAIN IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED EXTERIOR STEPS OUTSIDE OF THE KITCHEN BY LODING DOCK
#35731800P
Jun 12, 2026
POP/IN-VIO
$0
May 21, 2026Construction CLASS - 2
REISSUE #35724628R DATE OF ISSUE: 09/10/2025. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANR MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED INTERIOR SMOKE DOORS DO NOT SELF-CLOSE PROPERLY. 1ST FLOOR STAIR
#35733024K
Jun 26, 2026
POP/IN-VIO
$0
Sep 10, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: INTERIORSMOKE DOORS DO NOT SELF-CLOSE PROPERLY. 1ST FLR-"STAIR A", "GYM DOOR D", "CAFETERIA EXIT NEAR RM 111". BASEMENT-"BOILER ROOM EXIT". CLASSROO
#35724628R
Oct 31, 2025
POP/IN-VIO
$0
Sep 10, 2025Construction CLASS - 2
RE-ISSUE #35692234K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVED AR "STAIRCASE C" BETWEEN 5TH AND 4TH FLR 8 PANELS ARE MISSING ON THE STAIRCASE. REMEDY: REPAIR AND/OR REPLACE PANELS.
#35724626N
Oct 31, 2025
POP/IN-VIO
$0
Sep 10, 2025Construction CLASS - 2
RE-ISSUE #35676376X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT THE TIME OF INSPECTION, OBSERVED THAT THE EXTERIOR STEPS OUTSIDE OF THE KITCHEN BY THE LOADING DOCK IS CRACKED AND UNEVEN. R
#35724627P
Oct 31, 2025
POP/IN-VIO
$0
Sep 10, 2025Construction CLASS - 2
RE-ISSUE #35692237X. EXIT DOOR NOT SELF-CLOSING. EXIT DOOR NOT SELF-CLOSING PROPERLY. AT TIME OF INSPECTION AT THE ROOF "STAIR C" EXTERIOR DOOR. REMEDY: REPAIR/REPLACE DOOR.
#35725299J
Oct 31, 2025
POP/IN-VIO
$0
Sep 10, 2025Construction CLASS - 2
RE-ISSUE #35692235M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PERBC 1006.1; 27-381. NOTED: AT THE TIME OF INSPECTION OBSERVED EMERGENCY
#35724625L
Oct 31, 2025
POP/IN-VIO
$0
Oct 7, 2024Construction CLASS - 2
REISSUE #35676320R. DATE OF ISSUE: 07/10/2023. EXIT DOOR NOT SELF-CLOSING PROPERLY AT THE TIME OF INSPECTION. AT STAIR "A" 1ST FLOOR ONE EXIT NOT SELF-CLOSING PROPERLY, AT 2ND FLOOR AUDITORIUM ONE EXIT DOOR NOT
#35692237X
Nov 1, 2024
POP/IN-VIO
$0
Oct 7, 2024Construction CLASS - 2
REISSUE #35676322K. DATE OF ISSUE: 07/10/2023. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. AT THE TIME OF INSPECTIO
#35692235M
Nov 1, 2024
POP/IN-VIO
$0
Oct 7, 2024Construction CLASS - 2
REISSUE #35676323M. DATE OF ISSUE: 07/10/2023. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, OBSERVED AND NOTED THAT AT ROOM 507 AND STAIRCASE "C" BETWEEN 5TH AND 4TH FL THER
#35692234K
Nov 1, 2024
POP/IN-VIO
$0
Jul 10, 2023Construction CLASS - 2
REISSUE #35657866P DATE OF ISSUE: 05.27.22 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED THAT AT STAIR CASE "C" BETWEEN 5TH AND 4TH FLOOR THERE APPROX 8 PANELS MISSIN
#35676317X
Nov 3, 2023
POP/IN-VIO
$0
Jul 10, 2023Construction CLASS - 2
REISSUE #35657867R DATE OF ISSUE: 05.27.22 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1,27.2381 AT THE TIME OF INSPECTION OBSE
#35676322K
Nov 3, 2023
POP/IN-VIO
$0
Jul 10, 2023Construction CLASS - 2
REISSUE #35657863J DATE OF ISSUE: 05.27.22 EXIT DOORS ARE NOT SELF CLOSING PROPERLY AT THE TIME OF INSPECTION OBSERVED THAT AT 1ST FLOOR AUDITORIUM. REAR RIGHT DOOR & AT CAFETERIA. 3 EXIT DOORS ARE NO SELF CLOS
#35676320R
Nov 3, 2023
POP/IN-VIO
$0
Jul 10, 2023Construction CLASS - 2
REISSUE #35655338M DATE OF ISSUE: 06.02.21 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED THAT THE EXTERIOR STEPS OUTSIDE OF THEK ITCHEN BY THE LODING DOCK AND PARKING
#35676376X
Nov 3, 2023
POP/IN-VIO
$0
May 27, 2022Construction CLASS - 2
REISSUE#35577214J.EXIT DOOR NOT SELF-CLOSING.NOTED OBSERVED AT EXIT 7 MIDDLE JAMB IS LOOSE/ATTACHED,DOOR NOT CLOSING PROPERLY,EXIT 4 DOOR NOT OPENING PROPERLY,CAFETERIA FPSC DOORS BY EXIT 5,AUDITORIUM REAR RIGH
#35657863J
Sep 2, 2022
POP/IN-VIO
$0
May 27, 2022Construction CLASS - 2
REISSUE#35577216N.FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED OBSERVED AT STAIR C WALL THAT DIVIDES STAIRWELLS IS MISSING ITS GLASS WIRE MESH PANELS ON 4TH FLOOR UP TO THE 5TH FLOOR.REMEDY:REPAI
#35657866P
Sep 2, 2022
POP/IN-VIO
$0
May 27, 2022Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC1006.1;27-381.NOTED EXISTING EMERGENCY LIGHTS WITH BATTERY BACK-UP POWER THROUGHOUT 1ST FLO
#35657867R
Sep 2, 2022
POP/IN-VIO
$0
Jun 3, 2021Construction CLASS - 2
REISSUE#35500914P EXIT DOOR NOT SELF CLOSING. NOTE: DURING INSPECTION OBSERVED AT 4TH FL-STAIR'C'DOOR IS NOT CLOSING PROPERLY WHEN TESTED. REMEDY: REPAIR/REPLACE DOOR.
#35577214J
Oct 29, 2021
POP/IN-VIO
$0
Jun 3, 2021Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: DURING INSPECTION OBSERVED AT STAIRCASE'C'BETWEEN THE 5TH & 4TH FL. THERE APPROX 7PANELS MISSING BETWEEN THE STAIRCASE WHICH CAN TURN INTO SOMEONE GETTI
#35577216N
Oct 29, 2021
POP/IN-VIO
$0
Jun 25, 2020Construction CLASS - 2
EXIT DOOR NOT SELF CLOSING. NOTED: EXIT 2 DOOR BY THE STAIRCASE'G'NOT SELF CLOSED. ALSO ROOM 401 DOOR NOT CLOSE. STAIRCASE'C'4TH FL EXIT DOOR IS NOT SELF CLOSE. REMEDY: REPAIR & OR REPLACE.
#35500914P
Oct 2, 2020
POP/IN-VIO
$0
Jun 25, 2020Construction CLASS - 2
REISSUE#35423346J. FAILURE TO MAINTAIN BLDG WALL & APPURTENANCES AT EXP#2 MISSING MORTOR AT BRICK THROUGHTOUT WHOLE FACADE MAINLY 3RD,4TH,& 5TH FLOORS,CAUSING WATER PENETRATION ROOM 505,405(A,B),305,205.
#35500913N
Oct 2, 2020
POP/IN-VIO
$0
Jul 11, 2019Construction CLASS - 2
FAILURE TO MAINTAIN BLD.WALLS AND APPURTENANCES.SPALLING AND MISSING MORTAR AT BRICKS THROUGHOUT ALL FACADE EXPOSURES MAINLY 4TH & 5TH FLOORS.REM:COMPLY WITH CODE ,MAINTAIN EXTERIOR BLD.WALLS.
#35423346J
Sep 20, 2019
POP/IN-VIO
$0
DOB (3)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06443
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06445
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06444
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 3:25 AM ET. BBL 2031040007.