Manhattan · Block 385 · Lot 49 · 10009

242 East 2 Street

7 floors · 24 apartments · 34,821 sq ft · built 2005 · class D7 · owner of record: Diversity Houses Hsg Devel Fdg Co

44open violations
$0ECB/OATH penalties owed
9HPD class C (immediately hazardous)
44dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $229,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 96 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 34,821 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 165 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 165 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 288 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 775 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-19 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4)
IssuedViolationHearingBalance
Dec 9, 2022Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #913952.REMEDY:SUBMIT ACCEPTABLE REQUIRED TE
#37024840J
Mar 2, 2023
IN VIOLATION
$0
Oct 4, 2022Elevators CLASS - 2
2/X/10 OUT SIDE COMM INOPERATIVE REPAIR.
#39071340H
Dec 1, 2022
IN VIOLATION
$0
May 18, 2018Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#813952. REMEDY: SUBMIT REQUIRED TECHNICAL REPORT
#37011108X
Dec 20, 2018
IN VIOLATION
$0
Apr 11, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BLDG EXTERIOR FACADE & APPURTENANCES. NOTED: @ TIME OF INSP. SOUTH ELEVATION EXP#1, LOOSE WOOD ON WINDOW SILLS & WOOD SUPPORTING UNDER AIR CONDITION UNIT. REM: MAINTAIN EXTERIOR BLDG FACADE
#35318702M
Dec 13, 2018
IN VIOLATION
$0
DOB (3)
IssuedViolationStatus
Dec 1, 2024FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2400060
DOB VIOLATION - ACTIVE
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#01735
DOB VIOLATION - ACTIVE
May 31, 2018NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
#00144
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Dec 1, 2024Energy Grade - LL33 FTP-EN-EGRDEA
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
May 31, 2018Facades FISPNRF
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
Active
HPD (33) · C 9 · B 21 · A 3
IssuedClassViolationCorrect by
Aug 21, 2026BApt 6A · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHSep 25, 2026
Aug 21, 2026BApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHSep 25, 2026
Apr 17, 2025CApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHApr 23, 2025
Apr 17, 2025CApt 6A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHApr 17, 2025
Jan 18, 2024BApt 6A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 6A, 66th STORY, 1st APARTMENT FROM WEST AT NORTHFeb 22, 2024
Jan 18, 2024BApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 6A, 66th STORY, 1st APARTMENT FROM WEST AT NORTHFeb 22, 2024
Oct 4, 2023AApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHJan 7, 2024
Oct 4, 2023AApt 6A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHJan 7, 2024
Aug 3, 2023BApt 6B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHSep 7, 2023
Aug 3, 2023BApt 6B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHSep 7, 2023
Jun 8, 2023BApt 6A · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHJul 13, 2023
Jun 8, 2023BApt 6A · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHJul 13, 2023
Jun 8, 2023CApt 6A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 1; MISSING ONE WAY SCREWS AT 1 AIR CONDITIONING WINDOW IN THE ENJul 4, 2023
Jun 8, 2023BApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHJul 13, 2023
Jun 8, 2023BApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHJul 13, 2023
Apr 10, 2023CApt 6A · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATHROOM AND KITCHEN. IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTHApr 16, 2023
Apr 10, 2023CApt 6A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0, WG TO REPLACE = 0, WG TO REPAIR = 1 IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 1st APARMay 6, 2023
Apr 10, 2023BApt 6A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING. IN THE 1st ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTHMay 15, 2023
Apr 10, 2023BApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING. IN THE 1st ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTHMay 15, 2023
Apr 10, 2023BApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING. IN THE 2nd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTHMay 15, 2023
Apr 10, 2023BApt 6A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTHMay 15, 2023
Oct 21, 2022BApt 7C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 4th ROOM FROM EAST LOCATED AT APT 7C, 7th STORY, 1st APARTMENT FROM WEST AT NORTHNov 25, 2022
Oct 19, 2022BApt 7C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 7C, 7th STORY, 1st APARTMENT FROM WEST AT NORTHNov 23, 2022
Oct 19, 2022BApt 7C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND NORTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 7C, 7th STORY, 1st APARTMENT FROM WEST AT NORTHNov 23, 2022
Oct 19, 2022CApt 7C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 20 SQ. FT AT SOUTH WALL AND 10 SQ. FT AT CEILING INSIDE CLOSET IN THE 4th ROOM FROM EAST LOCATED AT APT 7C, 7th STORY, 1st APARTMENT FROM WEST AT NORTHNov 14, 2022
Oct 19, 2022BApt 7C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 7C, 7th STORY, 1st APARTMENT FROM WEST AT NORTHNov 23, 2022
Oct 19, 2022BApt 7C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING INSIDE 4TH CLOSET FROM EAST AT SOUTH IN THE PRIVATE HALLWAY LOCATED AT APT 7C, 7th STORY, 1st APARTMENT FROM WEST AT NORTHNov 23, 2022
Oct 3, 2022BApt 7C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 7C, 7th STORY, 1st APARTMENT FROM WEST AT NORTHNov 7, 2022
Oct 3, 2022BApt 7C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 7C, 7th STORY, 1st APARTMENT FROM WEST AT NORTHNov 7, 2022
Feb 11, 2022CApt 7C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 7C, 7th STORY, 1st APARTMENT FROM WEST AT NORTHFeb 17, 2022
Jun 11, 2021AApt 4C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTHSep 14, 2021
Mar 15, 2021C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM NO ACCESS TO BOILER ROOM AT BOILER ROOM, 1st STORYMar 21, 2021
Nov 6, 2019C§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WATER PIPE CONNECTION TO BOILER SYSTEM LOCATED AT ROOF AT BOILER ROOMNov 14, 2019

Issued in the last 120 days

DateSourceWhatNow
Aug 21, 2026HPD B§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Aug 21, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 8:22 PM ET. BBL 1003850049.