Queens · Block 13256 · Lot 4 · 11422

241-13 North Conduit Avenue

2 floors · 1 apartments · 2,308 sq ft · built 2007 · class K4 · owner of record: North Conduit Holding Corp.

11open violations
$0ECB/OATH penalties owed
1HPD class C (immediately hazardous)
43dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-22 (Accepted). Agency page

Dec 31, 2026
in 43 days
1 of 1 without an accepted 2026 report yet
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 287 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1139 days
Next cycle year 2029

Open violations

ECB / OATH (0)

None open.

DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (11) · C 1 · B 6 · A 4
IssuedClassViolationCorrect by
Feb 22, 2019BApt 2NDFL · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2NDFL, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 29, 2019
Feb 22, 2019BApt 2NDFL · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 2NDFL, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 29, 2019
Feb 22, 2019BApt 2NDFL · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULK AT THE SEAM BETWEEN BATHTUB AND WALL TILE IN THE 2nd BATHROOM FROM NORTH AT WEST LOCATED AT APT 2NDFL, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 29, 2019
Feb 22, 2019BApt 2NDFL · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2NDFL, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 29, 2019
Feb 22, 2019CApt 2NDFL · § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE HANDRAIL TO WALL AT STAIRS TO 2ND STORY LOCATED AT APT 2NDFL, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 2, 2019
Feb 22, 2019BApt 2NDFL · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE AT FLOOR IN THE KITCHEN LOCATED AT APT 2NDFL, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 29, 2019
Feb 22, 2019BApt 2NDFL · § 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SHOWER IN THE 1st BATHROOM FROM NORTH AT WEST LOCATED AT APT 2NDFL, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 29, 2019
Sep 6, 2017AApt 2FL · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORYDec 10, 2017
Sep 6, 2017AApt 2FL · § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WOODEN WINDOW FRAMES IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2FL, 2nd STORYDec 10, 2017
Sep 6, 2017A§ 27-2010, 2011, 2012 ADMIN CODE: CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE CARPET AT PUBLIC HALL, 1st STORYDec 10, 2017
Sep 6, 2017A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYDec 10, 2017

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 3:38 AM ET. BBL 4132560004.

Look up another building