Bronx · Block 3105 · Lot 57 · 10458

2409 Crotona Avenue

4 floors · 8 apartments · 6,800 sq ft · built 1915 · class C1 · owner of record: Kpk Realty Llc

120open violations
$0ECB/OATH penalties owed
43HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 56 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 56 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 56 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 72 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-26 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (0)

None open.

DOB NOW Safety (2)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
HPD (118) · C 43 · B 65 · A 10
IssuedClassViolationCorrect by
Aug 24, 2026CApt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10SQ.FEET AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18477274 ISSUED 02-DEC-25 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATSep 19, 2026
Apr 20, 2026BApt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL LESS THAN 10 SQ.FT IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18520680 ISSUED 15-DEC-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017May 25, 2026
Dec 19, 2025B§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF TOILET FIXTURE , 4th STORYJan 23, 2026
Dec 19, 2025A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 4th STORYMar 24, 2026
Dec 19, 2025B§ 27-2005 ADM CODE PROVIDE WIRE SCREEN BELOW SKY LIGHT AT BULKHEAD , 4th STORYJan 23, 2026
Dec 19, 2025A§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE-RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 1st STORYMar 24, 2026
Dec 19, 2025A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1st STORYMar 24, 2026
Dec 19, 2025CApt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJan 14, 2026
Dec 19, 2025A§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE-RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 4th STORYMar 24, 2026
Dec 3, 2025CApt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM NORTH AT EASTDec 29, 2025
Dec 1, 2025BApt 6 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 5, 2026
Dec 1, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED AT BOILER ROOMDec 7, 2025
Dec 1, 2025BApt 6 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 5, 2026
Dec 1, 2025CApt 6 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 2nd ROOM FROM EAST LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 29, 2025
Oct 7, 2025CApt 3 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTNov 2, 2025
Oct 7, 2025BApt 3 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTNov 11, 2025
Oct 7, 2025BApt 3 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTNov 11, 2025
Jul 15, 2025BApt 6 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT WEST WALL IN THE BATHROOM LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17763471 ISSUED 16-MAR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-201Aug 19, 2025
Jul 15, 2025BApt 5 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT WEST AND SOUTH WALLS IN THE BATHROOM LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17763545 ISSUED 16-MAR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE COAug 19, 2025
Jul 15, 2025BApt 3 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT CEILLING EAST AND SOUTH WALLS IN THE BATHROOM LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17763538 ISSUED 16-MAR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTAug 19, 2025
Jul 15, 2025BApt 5 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT NORTH IN THE PRIVATE HALLWAY LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17763546 ISSUED 16-MAR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2Aug 19, 2025
Jul 15, 2025BApt 3 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT EAST AND NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17763541 ISSUED 16-MAR-25 HAS BEEN UPGRADED TO CLASS B PERAug 19, 2025
Jul 15, 2025BApt 5 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17763544 ISSUED 16-MAR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017Aug 19, 2025
Jul 15, 2025BApt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT EAST AND SOUTH WALLS IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17763533 ISSUED 16-MAR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE COAug 19, 2025
Jul 9, 2025BApt 5 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT. AT CEILING AND WEST WALL IN APARTMENT 5 IN THE BATHROOM LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17749491 ISSUED 10-MAR-25 HAS BEEN UPGRADED TO CLASS B PERAug 13, 2025
Jun 20, 2025B§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE THE OBSTRUCTION IN FIREPROOF PASSAGEWAY CONSISTING OF CHAIN AND LOCK AT DOOR AT FIRE PASSAGE WAYJul 25, 2025
Jun 20, 2025B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETEAT RETAINING WALL AT BUILDING REARJul 25, 2025
May 27, 2025BApt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... ,LESS THAN 10 SQFT. AT EAST AND SOUTH WALLS IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17645030 ISSUED 24-JAN-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE Jul 1, 2025
May 23, 2025BApt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT SOUTHWALL AND LESS THAN 10SQ FT AT EAST WALL IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17638803 ISSUED 22-JAN-25 HAS BEEN UPGRADED TO CLASSJun 27, 2025
Apr 22, 2025BApt 7 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE AT CEILING LIGHT FIXTURE IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EASTMay 27, 2025
Apr 22, 2025BApt 7 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EASTMay 27, 2025
Apr 22, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOMApr 28, 2025
Apr 22, 2025B§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF GARBAGE BAGS, 4TH STORY AT PUBLIC HALLMay 27, 2025
Apr 22, 2025BApt 7 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE AT CEILING LIGHT FIXTURE IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EASTMay 27, 2025
Apr 22, 2025B§ 27-2005 ADM CODE PROVIDE AN UNLOCKABLE SLIDE BOLT OR HOOK ON ROOF DOOR THAT ALLOWS RE-ENTRY FROM ROOF TO PUBLIC HALL AT WEST 1 BULKHEAD AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 4th STORYMay 27, 2025
Apr 22, 2025B§ 27-2005 ADM CODE PROVIDE AN UNLOCKABLE SLIDE BOLT OR HOOK ON ROOF DOOR THAT ALLOWS RE-ENTRY FROM ROOF TO PUBLIC HALL AT EAST 1 BULKHEAD AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 4th STORYMay 27, 2025
Apr 22, 2025B§ 27-2005 ADM CODE PROVIDE APPROVED WIRE TYPE MESH UNDER SKYLIGHT AT 4TH STORY AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 4th STORYMay 27, 2025
Apr 22, 2025A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE CONSTRUCTION MATERIAL AIR CONDITIONER UNDERNEATH SOFIT AT 1ST STORY AT PUBLIC HALLJul 26, 2025
Mar 17, 2025BApt 2 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTApr 21, 2025
Mar 17, 2025CApt 6 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTApr 12, 2025
Mar 17, 2025CApt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTApr 12, 2025
Mar 17, 2025BApt 3 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTApr 21, 2025
Mar 17, 2025CApt 6 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL, EAST WALL, WEST WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 6, Apr 10, 2025
Mar 17, 2025CApt 6 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 6, 3rd STORY,Apr 10, 2025
Mar 17, 2025CApt 6 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL, EAST WALL IN THE KITCHEN LOCATED AT APT 6, 3rd STORY, 1st APARApr 10, 2025
Mar 17, 2025AApt 6 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJun 20, 2025
Mar 17, 2025BApt 3 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTApr 21, 2025
Mar 17, 2025CApt 3 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTApr 12, 2025
Mar 17, 2025BApt 2 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTApr 21, 2025
Mar 17, 2025CApt 6 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTApr 12, 2025
Mar 17, 2025AApt 6 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJun 20, 2025
Mar 11, 2025CApt 5 · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES NO GAS TO STOVE IN THE KITCHEN LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTMar 17, 2025
Mar 11, 2025CApt 5 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTMar 11, 2025
Jan 27, 2025BApt 2 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMar 3, 2025
Jan 27, 2025BApt 2 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMar 3, 2025
Jan 27, 2025BApt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMar 3, 2025
Jan 27, 2025CApt 2 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJan 25, 2025
Jan 27, 2025BApt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT SWITCH AT SOUTH WALL IN THE FOYER LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMar 3, 2025
Jan 27, 2025BApt 2 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMar 3, 2025
Jan 23, 2025CApt 2 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJan 23, 2025

Showing 60 of 118. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Aug 24, 2026HPD C§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10SQ.FEET AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18477274 ISSUED 02-DEC-25 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 5, 2026, 3:13 PM ET. BBL 2031050057.