Bronx · Block 4424 · Lot 10 · 10467

2404 Bronx Park East

2 floors · 3 apartments · 3,036 sq ft · built 1960 · class C0 · owner of record: Gil, Ramon

42open violations
$11,750ECB/OATH penalties owed
5HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 48 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 48 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 64 days
Annual
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 413 days
Next cycle year 2027

Open violations

ECB / OATH (7) · $11,750 owed
IssuedViolationHearingBalance
Sep 29, 2026Construction CLASS - 1
4. FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1 (2008 CODE); 27-366; BC 1021.1 (2014 CODE). NOTED: AT TIME OF INSPECTION - 1ST
#39206137H
Dec 4, 2026
PENDING
$2,500
Sep 29, 2026Construction CLASS - 1
2. CONTRARY TO C-OF-O 32127 WHICH INDICATES CELLAR AS BOILER & STORAGE: AT TIME OF INSPECTION - CELLAR WAS OBSERVED CREATED & OCCUPIED AS LIVING SPACE WITH 3 PC BTHRM; ELECTRIC COOKING (HOT-PLATE); BDRM & SLEEP
#39206135Y
Dec 4, 2026
PENDING
$2,500
Sep 29, 2026Construction CLASS - 3
7. ILLEGAL PARKING IN A RESIDENTIAL DISTRICT. AT TIME OF INSPECTION - OBSERVED CONTRARY TO C-OF-O WHICH DOES NOT INDICATE OFF STREET PARKING MULTIPLE VEHICLES WERE OBSERVED PARKED AT EXPOSURE'S 1 & 3: BLUE KIA
#39206136X
Dec 4, 2026
PENDING
$500
Sep 29, 2026Unknown CLASS - 2
1. W/O A PERMIT. NOTED: AT CELLAR - ADDL'T ELECTRICAL WIRING INSTALLED FOR LIGHTS, OUTLETS, SWITCHES, BRANCH CIRCUITS., OBTAIN PERMIT
#39206134M
Dec 4, 2026
PENDING
$1,250
Sep 29, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: 1. AT CELLAR & 1ST FLR LEVELS - UNSAFE ELECTRICAL WIRING OBSERVED CONSISTING OF 100' EXTENSION CORDS PASSING THROUGHOUT & 18 GAUGE EXPOSED WIRE USED
#39206139L
Dec 4, 2026
PENDING
$2,500
Sep 29, 2026Construction CLASS - 2
3. W/O A PERMIT. NOTED: AT CELLAR WATER & WASTE LINES INSTALLED FOR A 3 PC BTHRM (TOILET, SINK, SHOWER). ALSO AN ADDL'T SHOWER STALL INSTALLED AT 3RD FLR BTHRM., OBTAIN ALL PERMITS
#39206133K
Dec 4, 2026
PENDING
$1,250
Sep 29, 2026Construction CLASS - 2
5. W/O A PERMIT. NOTED: 1. AT CELLAR - FULL HEIGHT PARTITION WALLS ERECTED AT VARIOUS LOCATIONS TO CREATE A BDRM & BTHRM: ALSO, TO SUB-DIVIDE LEVEL FRONT & REAR. 2. REAR DETACHED GARAGE DEMOED., OBTAIN ALL PERM
#39206138J
Dec 4, 2026
PENDING
$1,250
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 11)
Active
HPD (34) · C 5 · B 22 · A 7
IssuedClassViolationCorrect by
Aug 31, 2026BApt 1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR LOCK IN THE ENTRANCE LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOct 5, 2026
Aug 31, 2026BApt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOct 5, 2026
Aug 31, 2026AApt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING LESS THAN 10 SQ.F IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHDec 4, 2026
Aug 31, 2026BApt 1 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATH TUB IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOct 5, 2026
Aug 31, 2026BApt 1 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOct 5, 2026
Aug 31, 2026BApt 1 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOct 5, 2026
Aug 21, 2026CApt 1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTSep 16, 2026
Aug 21, 2026BApt 1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTSep 25, 2026
Aug 21, 2026CApt 1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTSep 16, 2026
Aug 21, 2026BApt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQ.FT AT CEILING AND NORTH AND WEST WALL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTSep 25, 2026
Aug 21, 2026BApt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTSep 25, 2026
Aug 21, 2026BApt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTSep 25, 2026
Aug 21, 2026BApt 1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SHOWER HEAD IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTSep 25, 2026
Aug 21, 2026BApt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTSep 25, 2026
Aug 21, 2026BApt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTSep 25, 2026
Aug 21, 2026BApt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTSep 25, 2026
Aug 21, 2026BApt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTSep 25, 2026
Aug 21, 2026CApt 1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTSep 16, 2026
Apr 29, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 2, 2026
Mar 27, 2026BApt 1 · § 27-2077 ADM CODE DISCONTINUE THE ROOMING UNIT OCCUPIED BY ONE ADULT ( ELENA TAPIA ) IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHMay 1, 2026
Mar 27, 2026BApt 1 · § 27-2077 ADM CODE DISCONTINUE THE ROOMING UNIT OCCUPIED BY 2 ADULTS ( ORLANDO AND ESTEBAN VILA ) IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHMay 1, 2026
Mar 16, 2026BApt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 30SQ FT AT CEILING AND SOUTH WALL IN THE FOYER LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTApr 20, 2026
Mar 16, 2026CApt 1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTApr 11, 2026
Mar 9, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGE AT DOOR (WOOD) BUILDING ENTRANCE (LEADING TO PUBLIC HALL FROM COURT YARD) , 1st STORYMar 23, 2026
Mar 9, 2026BApt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 20 SQ FT AT WEST WALL AND SOUTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTApr 13, 2026
Mar 9, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 1st STORYApr 13, 2026
Mar 9, 2026BApt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 20SQ FT AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTApr 13, 2026
Sep 25, 2025B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE AT REAR YARDOct 30, 2025
Sep 25, 2025B§ 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL.Oct 30, 2025
Jun 4, 2025A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Sep 7, 2025
Apr 2, 2024A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jul 6, 2024
Mar 16, 2023A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jun 19, 2023
Feb 17, 2022A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.May 23, 2022
Apr 2, 2021A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jul 6, 2021

Issued in the last 120 days

DateSourceWhatNow
Sep 29, 2026ECBConstruction: 4. FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1 (2008 CODE); 27-366; BC 1021.1 (2014 CODE). NOTED: AT TIME OF INSPECTION - 1STOpen
Sep 29, 2026ECBConstruction: 2. CONTRARY TO C-OF-O 32127 WHICH INDICATES CELLAR AS BOILER & STORAGE: AT TIME OF INSPECTION - CELLAR WAS OBSERVED CREATED & OCCUPIED AS LIVING SPACE WITH 3 PC BTHRM; ELECTRIC COOKING (HOT-PLATE); BDRM & SLEEPOpen
Sep 29, 2026ECBConstruction: 7. ILLEGAL PARKING IN A RESIDENTIAL DISTRICT. AT TIME OF INSPECTION - OBSERVED CONTRARY TO C-OF-O WHICH DOES NOT INDICATE OFF STREET PARKING MULTIPLE VEHICLES WERE OBSERVED PARKED AT EXPOSURE'S 1 & 3: BLUE KIAOpen
Sep 29, 2026ECBUnknown: 1. W/O A PERMIT. NOTED: AT CELLAR - ADDL'T ELECTRICAL WIRING INSTALLED FOR LIGHTS, OUTLETS, SWITCHES, BRANCH CIRCUITS., OBTAIN PERMITOpen
Sep 29, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: 1. AT CELLAR & 1ST FLR LEVELS - UNSAFE ELECTRICAL WIRING OBSERVED CONSISTING OF 100' EXTENSION CORDS PASSING THROUGHOUT & 18 GAUGE EXPOSED WIRE USEDOpen
Sep 29, 2026ECBConstruction: 3. W/O A PERMIT. NOTED: AT CELLAR WATER & WASTE LINES INSTALLED FOR A 3 PC BTHRM (TOILET, SINK, SHOWER). ALSO AN ADDL'T SHOWER STALL INSTALLED AT 3RD FLR BTHRM., OBTAIN ALL PERMITSOpen
Sep 29, 2026ECBConstruction: 5. W/O A PERMIT. NOTED: 1. AT CELLAR - FULL HEIGHT PARTITION WALLS ERECTED AT VARIOUS LOCATIONS TO CREATE A BDRM & BTHRM: ALSO, TO SUB-DIVIDE LEVEL FRONT & REAR. 2. REAR DETACHED GARAGE DEMOED., OBTAIN ALL PERMOpen
Aug 31, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR LOCK IN THE ENTRANCE LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Aug 31, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Aug 31, 2026HPD A§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING LESS THAN 10 SQ.F IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Aug 31, 2026HPD B§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATH TUB IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Aug 31, 2026HPD B§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Aug 31, 2026HPD B§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Aug 21, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Aug 21, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Aug 21, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Aug 21, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQ.FT AT CEILING AND NORTH AND WEST WALL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Aug 21, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Aug 21, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Aug 21, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SHOWER HEAD IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Aug 21, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Aug 21, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Aug 21, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Aug 21, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Aug 21, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 13, 2026, 8:00 PM ET. BBL 2044240010.