Brooklyn · Block 7415 · Lot 7501 · 11235

2403 East 13th St

3 floors · 12 apartments · 8,117 sq ft · built 1975 · class R2 · owner of record: 2403 East 13th Owner Llc

9open violations
$0ECB/OATH penalties owed
3HPD class C (immediately hazardous)
63dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 63 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 79 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 307 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 15 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 428 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-02 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (1)
IssuedViolationStatus
Apr 4, 2026CONSTRUCTION
STRUCTURE RENDERED NONCOMPLIANT DUE TO VEHICLE IMPACT. EXPOSURE 2 LOAD BEARING WALL STRUCK CAUSING STRUCTURAL DAMAGE TO MAIN MASONRY SUPPORT COLUMN AS WELL AS INTERIOR AND EXTERIOR WALL AT APARTMENT 1D REMEDY: STRUCTURE MUST BE MAINTAINED IN A CODE COMPLIANT MANNER
#CER02JM
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Mar 3, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
Active
HPD (7) · C 3 · B 4 · A 0
IssuedClassViolationCorrect by
Apr 10, 2026CApt 3C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO PARTY WALL BALCONY IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHApr 16, 2026
Apr 10, 2026CApt 3A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 6, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARMay 6, 2026
May 7, 2012BApt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORYJun 11, 2012
Sep 27, 2007BApt 3A · § 27-2005 ADM CODE PROVIDE CHAIN GUARD AT DOOR IN THE ENTRANCE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHNov 1, 2007
Sep 27, 2007BApt 3A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHNov 1, 2007
Sep 27, 2007BApt 3A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHNov 1, 2007
Jun 4, 2004CApt 1B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ERODED MORTAR JOINTS BRICKWORK WATER ENTERING THROUGH NORTH WALL AT EAST 1 AND 2 ROOMS LOCATED AT APT 1B, 1st STORY, APARTMENT AT EASTJun 15, 2004

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 3:49 PM ET. BBL 3074157501.