17,906 sq ft · built 2023 · class H9 · owner of record: Far Rockaway Equities Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 16 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 61 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 26, 2026 | Construction CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE EXPIRED PERMIT. AT TIME OF INSPECTION AFTER DOING RESEARCH I FOUND PERMIT EXPIRED, ISSUING VIOLATION FOR EXPIRED PERMIT. REMEDY: RENEW PERMIT. #39554656K | Aug 26, 2026 DEFAULT | $6,250 |
| Apr 25, 2026 | Unknown CLASS - 2 BC 3303.3. AT THE TIME OF INSPECTION OF 8-STORY NEW BUILDING OF APPROXIMATELY 5800+ SQUARE FEET. UPON SHOUTING, WALKING THE PERIMETERS, BANGING ON FENCE & ENTRANCE GATE TO ALERT WATCH PERSON AND TO VERIFY COMPL #39553521Z | Jul 1, 2026 DEFAULT | $10,000 |
| Mar 19, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED I SIDEWALK SHED INSTALLED AT EXPOS 1&4 CONTRARY TO CODE. MULTIPLE MUDSILLS INSTALLED WITHIN 18 INCHES FROM THE FACE OF THE CURB LINE & NO PROTECTION FROM DISPLACEMENT AT DRIVEWAY CONT #39552011Y | May 27, 2026 DEFAULT | $5,000 |
| Mar 19, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1&4 NOT CONSTRUCTED OR MAINTAINED ACCORDING TO CODE. VIEWING PANELS WERE NOT 12X12 IN SIZE AND SOME MISSING COVERS AT EXPOS 1&4. PROTRUDING OBJECTS (NAILS, #39551994J | May 27, 2026 DEFAULT | $5,000 |
| Mar 19, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1&4 NOT MAINTAINED ACCORDING TO CODE. UN PROTECTED SHED BOLTS IN PATHWAY. DAMAGED AND BENT VERTICAL AND HORIZONTAL SHED MEMBERS AT EXPOS 1. REMOVED #39551995L | May 27, 2026 DEFAULT | $10,000 |
| Mar 19, 2026 | Construction CLASS - 1 UPON INSPECTION I OBSERVED INADEQUATE HOUSEKEEPING PRACTICES AT EXPOS 3. LARGE PILE OF TRASH AND COMBUSTIBLE MATERIAL STORED IN YARD CONTRARY TO CODE 3303.4.6 . THE INADEQUATE STORAGE IS A FIRE HAZARD (SIGNS OF #39552000Z | May 27, 2026 DEFAULT | $12,500 |
| Mar 19, 2026 | Unknown CLASS - 1 UPON INSPECTION OF AN ACTIVE 8 STORY NB I OBSERVED INADEQUATE INSTALLATION AND MISSING FIRE EXTINGUISHERS. NO EXTINGUISHERS ON 8TH FLR AND ROOF. MULTIPLE FLOORS WITH EXTINGUISHERS RESTING ON THE FLOOR (SHOULD B #39552005H | May 27, 2026 DEFAULT | $6,250 |
| Feb 8, 2026 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OF AN EIGHT-STORY NEW BUILDING, A SIDEWALK SHED WAS OBSERVED IN PLACE WITHOUT THE REQUIRED INFORMATION PANEL, CREATING A HAZARDOUS CONDITION AND IMPEDING FDNY ACCESS AND EMERGENCY R #39550156X | Apr 22, 2026 DEFAULT | $6,250 |
| Feb 8, 2026 | Unknown CLASS - 2 BC 3314.1AT THE TIME OF MY INSPECTION, I OBSERVED A PIPE SCAFFOLD AT EXPOSURE 3 NOT PROPERLY MAINTAINED, WITH LOOSE DEBRIS NETTING , CREATING A HAZARDOUS CONDITION TO THE PUBLIC AND PROPERTY. STOP ALL USE OF TH #39550155Y | Apr 22, 2026 DEFAULT | $10,000 |
| Jan 14, 2026 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OBSERVED SIDEWALK SHED AT EXP#1 PERMIT#B00934690-UPPON ASKIN FOR 6 MONTHS PERIODIC INSPECTION LETTERS AS PER BC 3307.6.5.8-NONE WAS PROVIDED #39549138Y | Mar 25, 2026 DEFAULT | $3,257 |
| Jan 14, 2026 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OBSERVED SIDEWALK SHED AT EXP#1 -POST OF SHED BENDED ,BRACING FROM POST TO POST BENDED,LOOSE PARAPET PANEL,PLANKS ON TOP OF SHED ROTTED, DETERIORATED-CORRUGATED SHEET NOT COVERED #39549132N | Mar 25, 2026 DEFAULT | $10,000 |
| Nov 10, 2025 | Construction CLASS - 2 OBSERVATION: AT EXPOSURES 1 & 2 CONSRUCTION FENCE PERMIT # B00484231-I1 EXPIRED 11/8/2025 RENEW PERMIT #39546818Y | Nov 12, 2026 DEFAULT | $1,280 |
| Sep 4, 2024 | Construction CLASS - 2 TIME OF INSPECTION OBSERVED NEEDLE BEAM INSTALLED AT 2ND FLOOR AND SCAFFOLD IS ON TOP AT EXP 2 ,UPON REVIEW APPROVED PLANS DETERMINE THAT INSTALLED SHORING POST INCORRECT WAY , AS PER PLANS POST SUPPOSED TO BE #39532089X | Jan 15, 2027 PENDING | $1,280 |
| Jun 28, 2024 | Construction CLASS - 2 AT THE TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE WITH EXCESSIVE DEBRIS AND MATERIAL STORED ON TOP OF THE SIDE WALK SHED AT EXPOSURE 1 & 2 WHICH IS CONTRARY TO CODE SPECIFICATIONS #39530137M | Jan 15, 2027 PENDING | $10,000 |
| Jun 28, 2024 | Unknown CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. ATTIME OF INSPECTION I OBSERVED ELEVATOR SHAFT USED AS STORAGE FOR EXCESSIVE DEBRIS AND WASTE MATERIAL ON FLOOR 2 THROUGH 8 CONTRARY TO CODE 3 #39530139X | Jan 15, 2027 PENDING | $6,250 |
| Jun 28, 2024 | Construction CLASS - 2 AT THE TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE IN PLACE CONTRARY TO CODE SPECIFICATIONS , SIDEWALK SHED DOES NOT EXTEND 5 FEET PASS THE WORK AREA AT EXPOSURE 1 & 2 CORNER WITH SUPPORTED SCAFFOLD IN #39530138Y | Jan 15, 2027 PENDING | $10,000 |
| Jun 28, 2024 | Construction CLASS - 1 AT THE TIME OF INSPECTION I OBSERVED INADEQUATE GUARDRAIL SYSTEM AROUND OPEN PERIMETERS AT BUILDING LEADING EDGE AND ELEVATOR SHAFT WHICH CREATES FALL HAZARD FOR WORKERS THAT CAN LEAD TO INJURIES / FATALITIES #39530121H | Jan 15, 2027 PENDING | $25,000 |
| Jun 28, 2024 | Construction CLASS - 2 AT THE TIME OF INSPECTION UPON REQUEST TO SEE AND VERIFY DOCUMENTS NON WAS PROVIDED OR PRESENTLY ON SITE AS PER CODE 3301.7 . NO SUPPORTED SCAFFOLD DRAWINGS, SIDEWALK SHED AND SUPPORTED SCAFFOLD INSTALLATION L #39530123L | Jan 15, 2027 PENDING | $6,250 |
| Jun 28, 2024 | Construction CLASS - 2 I OBSERVED THAT THE CONSTRUCTION FENCE PANELS AT EXPOSURES 1& 4 NOT PROPERLY MAINTAINED PURSUANT TO SUBSECTION ACCORDING TO CODE 3307.7. PANELS WITH MULTIPLE GRATIFY, DETERIORATIVE WITH GAPS BETWEEN PLYWOOD, BU #39530125P | Jun 16, 2025 DEFAULT | $0 |
| Dec 9, 2023 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION I OBSERVED SIDEWALK SHED INSTALLED AT EXPOSURE # 4 WITH BRACING FROM POST TO POST OPEN/NOT CONNECTED/REMOVED ALSO MISSING CONSTRUCTION SIGN ON PARAPET OF SIDEWALK SHED #39523961P | Dec 10, 2024 IN VIOLATION | $0 |
| Oct 21, 2022 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION, I OBSERVED A 4X8 PLYWOOD PANEL MEMBER OF THE FENCE COMPLETELY DETACHED, CREATING AN OPENING FOR THE PUBLIC AT EXPO#4. MULTIPLE PANELS ARE PEELING AWAY. FENCE IS NOT MAINTAINED AND #39507995N | Jun 26, 2023 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 12, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00097 | DOB VIOLATION - ACTIVE |
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 31, 2026, 6:00 AM ET. BBL 3014370006.