Brooklyn · Block 2395 · Lot 29 · 11211

239 South 1 Street

5 floors · 25 apartments · 25,310 sq ft · built 1915 · class D9 · owner of record: 240 Mulberry L L C

48open violations
$6,592ECB/OATH penalties owed
4HPD class C (immediately hazardous)
47dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 25,310 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 778 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-16 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (5) · $6,592 owed
IssuedViolationHearingBalance
Jul 30, 2026Elevators CLASS - 2
MISALINGED CAB MIRROR (B3 3001.6). DEFECTIVE CAR PHONE (2.27.1.1.3.). PROIVDE EXPLICITLY DETAILED INFO, POSTED, POSTED IN A CONSPICUOUS LOCATION, INDICATING HOW/WHERE TO OBTAIN KEYS TO ROOF/MACHINE ROOM.
#39198322M
Oct 14, 2026
DEFAULT
$655
Jul 3, 2025Elevators CLASS - 2
INOPERATIVE CAR PHONE. PROVIDE EXPLICITLY DETAILED INFO ON HOW/WHERE TO OBTAIN KEYS TO ROOF/MACHINE ROOM.
#39152809K
Oct 22, 2025
DEFAULT
$3,125
Jan 15, 2021Boilers CLASS - 2
REAR FLAME SIGHT GLASS MISSING-OIL PUMP NOT INTERLOCKED-BELT GUARD MISSING-ANTISYPHON + SHUTOFF VALVES MISSING AT TANK-TANK SIGN MISSING-WASTE OIL IN BOILER ROOM-CHIMNEY BASE DOOR INCORRECT-WATER GAUGE COCK DEF
#39034974R
May 19, 2021
DEFAULT
$1,562
Mar 24, 2020Elevators CLASS - 1
PROVIDE CURRENT BRAKE TAG. PROVIDE FIRE EXTINGUISHER. CLEAN MOTOR ROOM. CLEAN PIT. PROVIDE PIT LIGHT. NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC
#39020333J
Jul 29, 2020
IN VIOLATION
$1,250
Aug 19, 2004Construction Hazardous
WORK WITHOUT A PERMIT. HAZARDOUS. NOTE FULL PARTITON WALLS. PLUMBING & ELECTRIAL WORK ILLEGALLY ERECTED AT VARIOUS LOCATIONS IN REAR N/E SECTION OF CELLAR CREATING AN APT WITH A BATHROOM WITH A LINE, 3 ROOMS, C
#34450527X
Oct 4, 2004
DEFAULT
$0
DOB (4)
IssuedViolationStatus
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2003276
DOB VIOLATION - ACTIVE
Jan 31, 2005LOCAL LAW 62/91 - BOILERS

#21117
DOB VIOLATION - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#02906
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#39100
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Jan 31, 2005Boiler LL6291
Active
HPD (35) · C 4 · B 18 · A 13
IssuedClassViolationCorrect by
Nov 18, 2025BApt 3D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUT AND MORTAR JOINTS AROUND BATHTUB PERIMETER IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTHDec 23, 2025
Nov 18, 2025AApt 3D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH AND WEST WALLS IN THE KITCHEN LOCATED AT APT 3D, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTHFeb 21, 2026
Nov 18, 2025BApt 3D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTHDec 23, 2025
Nov 17, 2025CApt 3D · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTHNov 17, 2025
Mar 9, 2021BApt 1D · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, APARTMENT AT SOUTHApr 13, 2021
Mar 9, 2021AApt 1D · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ENTRANCE DOOR IN THE BATHROOM LOCATED AT APT 1D, 1st STORY, APARTMENT AT SOUTHJun 12, 2021
Mar 9, 2021BApt 1D · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, APARTMENT AT SOUTHApr 13, 2021
Oct 18, 2018AApt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHJan 21, 2019
Oct 18, 2018BApt 5B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 22, 2018
Aug 17, 2017AApt 1E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTHNov 20, 2017
Aug 17, 2017AApt 1E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTHNov 20, 2017
May 19, 2016BApt 2C · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTHJun 23, 2016
Apr 27, 2011CApt 3E · SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING PAD LOCK INSTALLED AT DOOR TO FIRE ESCAPE IN THE 1st ROOM FROM EAST LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHMay 3, 2011
Apr 27, 2011BApt 3E · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD CABINET UNDER SINK IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHJun 1, 2011
Oct 20, 2009CSECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM AT CELLAROct 26, 2009
Aug 14, 2008BApt 1D · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHSep 18, 2008
Aug 14, 2008BApt 1D · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHSep 18, 2008
Aug 14, 2008AApt 1D · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING METAL DOOR AT SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHNov 17, 2008
Aug 14, 2008AApt 1D · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD DRAWER AT SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHNov 17, 2008
Aug 14, 2008AApt 1D · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHNov 17, 2008
Aug 14, 2008AApt 1D · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT TUB IN THE BATHROOM LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHNov 17, 2008
Aug 14, 2008AApt 1D · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER TUBES AND ESCUTCHEONS AT SHOWER BODY IN THE BATHROOM LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHNov 17, 2008
Aug 14, 2008AApt 1D · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE AT NORTH WALL IN THE BATHROOM LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHNov 17, 2008
Aug 14, 2008AApt 1D · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE IN THE BATHROOM LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHNov 17, 2008
Aug 14, 2008AApt 1D · SECTION 27-2005 ADM CODE REFIT WOOD DOOR IN THE BATHROOM LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHNov 17, 2008
Apr 19, 2006BSECTION 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, .. AT CELLARMay 29, 2006
Apr 19, 2006BSECTION 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS .. AT CELLARMay 29, 2006
Apr 19, 2006BSECTION 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION APARTMENT ERECTED AT CELLARMay 29, 2006
Sep 15, 2005CSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING CEILING AT CELLAR THROUGHT.Sep 26, 2005
Sep 15, 2005BSECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTICAL WIRES AT CELLAR.Oct 25, 2005
Sep 15, 2005BSECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS EXIT DOOR AT CELLAR TO EAST COURT.Oct 25, 2005
Sep 9, 2005BApt 5B · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE. IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORYOct 19, 2005
Sep 9, 2005BApt 5B · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES. IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORYOct 19, 2005
Apr 19, 2005BApt 1E · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTHMay 29, 2005
Apr 19, 2005BApt 1E · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTHMay 29, 2005

Issued in the last 120 days

DateSourceWhatNow
Jul 30, 2026ECBElevators: MISALINGED CAB MIRROR (B3 3001.6). DEFECTIVE CAR PHONE (2.27.1.1.3.). PROIVDE EXPLICITLY DETAILED INFO, POSTED, POSTED IN A CONSPICUOUS LOCATION, INDICATING HOW/WHERE TO OBTAIN KEYS TO ROOF/MACHINE ROOM.Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 5:23 PM ET. BBL 3023950029.

Look up another building