6 floors · 70 apartments · 34,910 sq ft · built 1930 · class N9 · owner of record: San Miguel Housing Development Fund Comp Any, Inc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 34,910 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-01 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 12, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #1 WEST-CRACKED BRICK AT 1ST FLOOR LEVEL AT FRONT COURTYARD.-EXP #4 SOUTH-CRACKED BRICK BY WINDOWS AT 1ST #35730626Y | Mar 5, 2027 PENDING | $5,000 |
| Mar 22, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.OBSERVED:AT EXP#1(WEST ELEV)VERTICAL CRACK ON FACADE MASONRY BRICKS BETWEEN 5TH FLOOR AND ROOF PARAPET ON LEFT SIDE,SPALLING BRICKS/MORTAR JOINT AN #35682361Y | Jul 12, 2024 ADMIT/IN-VIO | $0 |
| Jun 1, 2021 | Boilers CLASS - 2 FOUND EXPOSED WIRING, OPENING ON CEILING AND WALLS, BOILER ROOM TO BE FIRE RATED, EXHAUST FAN AT REAR OF BOILER TO BE REMOVED, BODY DRAINS MISSING ON RELIEF VALVES. #39041985H | Jun 10, 2022 IN VIOLATION | $0 |
| Dec 5, 2019 | Construction CLASS - 2 EXPIRED PERMIT FOR CONSTR.EQUIPMENT.AT TIME OF INSPECTION,U RESPONSE TO COMPLAINT#2203100 OBSERVED SIDEWALK SHED IN PLACE WITH EXPIRED PERMIT ON 07/06/2017.TEMPORARY CONSTRUCTION EQUIPMENT REQUIRES A PERMIT OF #35424444H | Jan 31, 2020 DEFAULT | $3,125 |
| Dec 5, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN THE SIDEWALK SHED.AT TIME OF INSPECTION IN RESPONSE TO COMPLAINT#2293100 OBSERVED SIDEWALK SHED IN PLACE IN UNSAFE CONDITION WITH ITS PROPERTY WALL PANEL DETACHED AT ONE END AND OUT TO FALLS #35424438L | Jan 31, 2020 DEFAULT | $5,000 |
| Dec 5, 2019 | Construction CLASS - 2 FAILURE TO INSTALL AND MAINTAIN AS PER CODE SPECIFICATIONS.AT TIME OF INSPECTION IN RESPONSE TO COMPLAINT#2293100 OBSERVED SIDEWALK SHED IN PLACE WITH IT VERTICAL MEMBERS INCODE QUALITY PLACED ON SIDEWALK A SHO #35424440K | Jan 31, 2020 DEFAULT | $5,000 |
| Dec 5, 2019 | Cranes and Derricks CLASS - 1 FAILURE TO FILE EVIDENCE OF LIABILITY FOR PROPERTY DAMAGE INSURANCE.AT TIME OF INSPECTIION IN RESPONSE TO COMPLAINT#229310 OBSERVED SIDEWALK SHED IN PLACE AN UPON CHECKING UP THE DOB SYSTEM FOR GC'S GENERAL LIA #35424442Y | Jan 31, 2020 DEFAULT | $12,500 |
| Dec 5, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN SIDEWALK SHED.AT TIME OF INSPECTION,IN RESPONSE TO COMPLAINT #2203100 OBSERVED SIDEWALK SHED IN PLACE WITH EXPOSED SHARPEDGES/UNOCCUPIED PROTRUDING BOLT,CREATING HAZARDOUS CONDITIONS FOR PED #35424441M | Jan 31, 2020 DEFAULT | $5,000 |
| Dec 5, 2019 | Cranes and Derricks CLASS - 1 FAILURE TO FILE EVIDENCE OF COMPLIANCE WITH WORKERS COMP,AND/OR DISABILITY INSUARANCE AT TIME OF INSPECTION IN RESPONSE TO COMPLAINT #2293100 OBSERVED SIDEWALK SHED IN PLACE UPON CHECKUP THE DOB SYSTEM FOR GCS #35424443X | Jan 31, 2020 DEFAULT | $12,500 |
| Dec 5, 2019 | Construction CLASS - 2 FAILURE TO INSTALL AND MAINTAIN AS PER CODE SPECIFICATIONS.AT TIME OF INSPECTION, IN RESPONSE TO COMPLAINT#2293100 OBSERVED SIDEWALK SHEED IN PLACE IN UNSAFE CONDITION ,WITH ITS JUNIOR BEAMS INADEQUATELY INSTAL #35424439N | Jan 31, 2020 DEFAULT | $5,000 |
| Issued | Violation | Status |
|---|---|---|
| May 29, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00095 | DOB VIOLATION - ACTIVE |
| Apr 3, 2024 | CONSTRUCTION PARTIAL VACATE ORDER.OBSERVED CRACKED/DETERIORATED MASONRY,,STUCCO & W INDOW SILLS AT MULTIPLE LOCATIONS AT WEST,NORTH & EAST COURTYARDS(EXP# 2,3,4)THESE CONDITIONS HAVE MADE THE NORTH,WEST,& EAST COURTYARD UNABL E TO BE OCCUPIED EXCEPT IN EMERGENCY SITUATIONS.REMEDY:VACATE WEST #LL20501AE | DOB VIOLATION - ACTIVE |
| Mar 22, 2024 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO VERICAL CRACKED FACADE MASONRY BRICK & DET ERIORATED BRICKS AT EXP#1(WEST)SPALLING STUCCO AT MULITPLE LOCATIONS & CRACKED BRICKS AT EXP#2(NORTH)SPALLING AT EXP#3,CRACKED BRICKS AT EXP# 4(SOUTH)REMEDY:MAKE IMMEDIATE REPIAR UNDER SUPERVISION OF A LICENSED P ROFESSIONAL,MAIN #FA20501AE | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #23057 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #07786 | DOB VIOLATION - ACTIVE |
| Dec 1, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2101668 | DOB VIOLATION - ACTIVE |
| Jun 2, 2021 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00715 | DOB VIOLATION - ACTIVE |
| Jan 6, 1998 | LOCAL LAW 10/81 - ELEVATOR #01599 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| May 29, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Report | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Dec 1, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Jun 2, 2021 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jan 6, 1998 | Elevators LL1081 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 11, 2025 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR LEADING TO NORTH STAIRCASE AT PUBLIC HALL, 1st STORY | Jun 25, 2025 |
| Sep 12, 2024 | A | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER MISSING SHOE AT 1ST FROM NORTH AT WEST EXTERIOR WALL AT FIRE ESCAPE | Dec 16, 2024 |
| Jul 13, 2022 | A | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL | Oct 16, 2022 |
| Jul 13, 2022 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. | Oct 16, 2022 |
| Jul 13, 2022 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL | Oct 16, 2022 |
| Jun 17, 2022 | A | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT 1st FIRE ESCAPE FROM NORTH AT WEST | Sep 20, 2022 |
| Feb 10, 2021 | B | Apt 3B1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 1 SQUARE FOOT AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3B1, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 13852908 ISSUED 09-OCT-20 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §2 | Mar 17, 2021 |
| Apr 14, 2017 | B | Apt 2B2 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2B2, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | May 19, 2017 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 7:18 AM ET. BBL 2031520007.