7 floors · 21 apartments · 16,829 sq ft · built 2022 · class D3 · owner of record: 2380 Dean St Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 16 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 66 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | Feb 21, 2027 in 118 days | No Cycle 10 report on record yet |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 22, 2023 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OF A 7 STORY NEW BUILDING CONSTRUCTION WORK IN PROGRESS AT THE 6 FLOOR, I OBSERVED WORKING PLATFORM AT EXPOSURE # 2&4 UPON REQUEST FOR DESIGN DRAWING NONE WAS PROVIDED OR AT JOB SI #39516936H | Mar 4, 2024 IN VIOLATION | $312 |
| May 22, 2023 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 7 STORY NEW BUILDING CONSTRUCTION WORK IN PROGRESS AT THE 6 FLOOR, I OBSERVED LARGE AMOUNT OF GARBAGE/CONSTRUCTION DEBRIS AT EXPOSURE #3 SCATTERED ALL OVER THE BACK YARD AND TH #39516935X | Mar 4, 2024 IN VIOLATION | $2,500 |
| May 22, 2023 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 7 STORY NEW BUILDING CONSTRUCTION WORK IN PROGRESS AT THE 6 FLOOR, UPON REVIEW OF CONSTRUCTION SUPERINTENDENT LOG BOOK HE DID NOT SIGN IN FOR 4 DAYS AND RECORDING IN LOG BOOK S #39516937J | Mar 4, 2024 IN VIOLATION | $625 |
| May 22, 2023 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 7 STORY NEW BUILDING CONSTRUCTION WORK IN PROGRESS AT THE 6 FLOOR, I OBSERVED THAT THERE WERE NO OVERHEAD PROTECTION AT EXPOSURE #4 ADJOINING PROPERTY AND THERE WERE ONE PERSON #39516939N | Mar 4, 2024 IN VIOLATION | $2,500 |
| May 22, 2023 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 7 STORY NEW BUILDING CONSTRUCTION WORK IN PROGRESS AT THE 6 FLOOR, I OBSERVED VERTICAL SAFETY NETTING WAS INADEQUATELY INSTALL ON ALL FLOOR.THIS CREATES A HAZARDOUS CONDITION F #39516938L | Mar 4, 2024 IN VIOLATION | $625 |
| Jan 1, 2023 | Construction CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATION.NOTED ON THE EXP4 SIDE OF THE PROPERTY SIDE YARD OF 1814 EASTERN PKWY,CONCRETE DROPPING OVER SW PARKED IN SIDE YARD.STOP ALL WORK #35507738R | Sep 9, 2024 IN VIOLATION | $5,000 |
| Dec 16, 2022 | Unknown CLASS - 2 CONSTRUCTION SUPER FAILED TO PERFORM DUTIES PER CODE-NO COMPETENT PERSON.AS NOTED:ATOI@ACTIVE CONSTRUCTION SITE,OBSERVED MULTIPLE WORKERS BRINGING BAGS OF MATERIAL DOWN TO 1FL.UPON REQUEST OF COMPETENT PERSON F #35670225L | Apr 16, 2024 IN VIOLATION | $2,500 |
| Dec 9, 2022 | Unknown CLASS - 2 CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE AS NOTEDAT TIME OF MY INSPECTION OF ACTIVE JOBSITE OBSERVED(1)NO LOG FOR 12-09-2022 AND EVIDENCE THAT HE/SHE WAS PRESENT AT THE SITE(2)MISSING TIME #35669387X | Mar 11, 2024 IN VIOLATION | $2,500 |
| Dec 9, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS:AS NOTED:AT TIME OF MY INSPECTION OF ACTIVE JOBSITE OBSERVED IN ADEQUATE HOUSEKEEPING IN(1)AT EXPOSURE 1 BLACK GARBAGE BAYO AND BITS AND PIECES #35669386Y | May 12, 2025 IN VIOLATION | $2,500 |
| Nov 18, 2022 | Construction CLASS - 2 BC3301.7 FAILURE TO PROVIDE APPROVED/ACCEPTED CONST DOCS@JOBSITE ATOI.AS NOTED:ATOI@ACTIVE JOBSITE FOR PROPOSED 7STYB OBSERVED (A)MULTIPLE COLUMNS W/VERT REBAR W/INSUFFICIENT COVER OR W/NO COVER@ALL (B)SHEAR WA #35669353H | Apr 26, 2023 IN VIOLATION | $312 |
| Jun 1, 2022 | Construction CLASS - 2 3301.13.1 SITE SAFETY PLAN.AT TIME OF INSPECTION OF ACTIVE JOB SITE REVIEW OF SSP NO EGRESS & INADEQUATE SLOPED AS PER APPROVED SSP.REMEDY:STOP ALL WORK.CONFORM SITE TO SITE SAFETY PLAN. #35650039J | Jan 11, 2023 IN VIOLATION | $625 |
| Jun 1, 2022 | Construction CLASS - 1 3301.2 SAFETY MEASURES & STANDARDS.AT TIME OF INSPECTION OF ACTIVE SITE PROPOSED 7 STORY BUILDING OBSERVED SAFETY MEASURES NOT ADEQUATE MULTIPLE REBARS LESS THAN 2 FEET WERE NOT CAPPED UNSAFE CONDITION HAZARDOU #35650041Z | Jan 11, 2023 IN VIOLATION | $2,500 |
| Jun 1, 2022 | Unknown CLASS - 1 COMPETENT PERSON.AT TIME OF INSPECTION OF ACTIVE JOB SITE NO SUPER OR COMPETENT PERSON AT SITE.CONSTRUCTION WORKER GERSON DOMINGUEZ STATED HE WAS COMPETENT PERSON REVIEW OF DESIGNATION LETTER HIS NAME WAS NOT L #35650038H | Jan 11, 2023 IN VIOLATION | $2,500 |
| Jun 1, 2022 | Construction CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO GUARDRAIL,INADEQUATE.NOTE AT TIME OF INSPECTION AT A 7 STORY NEW BUILDING JOBSITE UNDER APP#321385728,OBSERVED MISSING GUARDRAIL AT #35641188Z | Jan 11, 2023 IN VIOLATION | $2,500 |
| Jun 1, 2022 | Unknown CLASS - 1 PERMIT HOLDER FAILED TO DESIGNATE A COMPETENT PERSON TO CONDUCT PRE-SHIFT MEETING OR TO ENSURE THAT SUCH COMPETENT PERSON.NOTE AT TIME OF INSPECTION AT A 7 STORY NEW BUILDING JOBSITE UNDER APP#321385728,OBSERVE #35641189K | Jan 11, 2023 IN VIOLATION | $5,000 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)