Brooklyn · Block 1443 · Lot 25 · 11233

2370 Pacific Street

3 floors · 7 apartments · 4,180 sq ft · built 1899 · class C1 · owner of record: 2370 Pacific Llc

24open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
64dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 16 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 64 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 64 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 80 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 308 days
Registered through 2027-09-01

Open violations

ECB / OATH (0)

None open.

DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 16)
Active
HPD (23) · C 0 · B 20 · A 3
IssuedClassViolationCorrect by
Oct 13, 2026AApt 3C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT OBSERVED AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 16, 2027
Oct 13, 2026BApt 3C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 17, 2026
Oct 13, 2026BApt 3C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 17, 2026
Oct 13, 2026B§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT PUBLIC HALL, 3rd STORYNov 17, 2026
Oct 13, 2026A§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT OBSERVED AT CEILING AT PUBLIC HALL, 3rd STORYJan 16, 2027
Oct 13, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT PUBLIC HALL, 3rd STORYNov 17, 2026
Oct 13, 2026A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 3rd STORYJan 16, 2027
Oct 13, 2026B§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF . AT PUBLIC HALL STAIRS, 3rd STORYNov 17, 2026
Sep 22, 2025BApt 3C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW FRAME 2ND WINDOW FROM EAST AT SOUTH IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 27, 2025
Sep 22, 2025BApt 3C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 27, 2025
Sep 22, 2025BApt 3C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 27, 2025
Mar 22, 2018BApt 1F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT THE SOUTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018
Mar 22, 2018BApt 1F · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LOCK ON THE DOOR LEADING TO THE PUBLIC HALL(2ND MEANS OF EGREES) IN THE 1st ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018
Mar 22, 2018BApt 1F · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT THE SHUT OFF VAVLE ON THE RADIATIOR LOCATED AT THE SOUTH WEST CORNER IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018
Mar 22, 2018BApt 1F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CELING AT THE NORTH-WESTERN CORNER IN THE 1st ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018
Mar 22, 2018BApt 1F · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018
Mar 22, 2018BApt 1F · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018
Mar 22, 2018BApt 1F · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT THE LOWER SASH AT THE 2ND WINDOW FROM EAST AT SOUTH IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018
Mar 22, 2018BApt 1F · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF LOOSE AND DEFECTIVE LIGHT SWITCH ON THE WEST WALL IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018
Mar 22, 2018BApt 1F · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF LOOSE ELECTRIC OUTLET AND SWITCH AT THE WEST WALL IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018
Mar 22, 2018BApt 1F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE TIN METAL CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018
Mar 22, 2018BApt 1F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018
Mar 22, 2018BApt 1F · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT THE BATHTUB IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, APARTMENT AT EASTApr 26, 2018

Issued in the last 120 days

DateSourceWhatNow
Oct 13, 2026HPD A§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT OBSERVED AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Oct 13, 2026HPD B§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Oct 13, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Oct 13, 2026HPD B§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT PUBLIC HALL, 3rd STORYOpen
Oct 13, 2026HPD A§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT OBSERVED AT CEILING AT PUBLIC HALL, 3rd STORYOpen
Oct 13, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT PUBLIC HALL, 3rd STORYOpen
Oct 13, 2026HPD A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 3rd STORYOpen
Oct 13, 2026HPD B§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF . AT PUBLIC HALL STAIRS, 3rd STORYOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 7:18 AM ET. BBL 3014430025.

Look up another building