Manhattan · Block 304 · Lot 16 · 10002

237 Grand Street

5 floors · 18,012 sq ft · built 1900 · class HH · owner of record: 125 Bowery Inc

154open violations
$64,980ECB/OATH penalties owed
32HPD class C (immediately hazardous)
66dto Annual boiler inspection (2 boilers)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-05-09 (Accepted). Agency page

Dec 31, 2026
in 66 days
2 of 2 without an accepted 2026 report yet
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 797 days
Next cycle year 2028

Open violations

ECB / OATH (19) · $64,980 owed
IssuedViolationHearingBalance
Sep 17, 2026Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED PARAPET WALL WITH LARGE CRACK ON CORNER OF EXPO 2 AT EXPO 3 SIDE. MULTIPLE CHIMNEY STACK ALSO MISSING MORTAR HOLDING THE BRICKS TOGETHER. AREA OF PARAPET/CHIMNEYS OVERHANGS PUBLI
#39204491L
Dec 3, 2026
PENDING
$2,500
May 30, 2026Unknown CLASS - 1
I OBSERVED EXTENSIONS CORD BEEN USE AS PERMANENT WIRING TO POWER SINGLE ROOMS, APPLIANCES AND LIGHT FIXTURES IN COMMERCIAL STORES.; NEC 400.12, COMPLY WITH EC CODE; FIX ALL CONDITIONS AS PER NEC AND NYC AMENDME
#39190504R
Aug 6, 2026
IN VIOLATION
$1,600
May 23, 2026Unknown CLASS - 1
I OBSERVED UNSAFE UNSUITABLE ELECTRICAL CONDITIONS THROUGHOUT GROUND, 3RD AND 5TH FLOORS, OPEN BOXES, WIRE HANGING AND EXPOSED SUBJECT TO ELECTROCUTIONS., COMPLY WITH EC; FIX ALL CONDITIONS AS PER NEC AND NYC A
#39190505Z
Aug 6, 2026
IN VIOLATION
$1,600
May 18, 2026Construction CLASS - 1
OBSERVED CUBICAL BEING INSTALLED AT 3RD FLOOR AND DEMOLISHED AT 5TH FLOOR. NO WORK ALLOWED TO CONSTRUCT OR DEMOLISH LIVING QUARTER CUBICAL SPACE. STOP THROUGHOUT ALL FLOORS OF THE PROPERTY (EXCEPT FOR EMERGENCY
#39189053Z
Feb 5, 2027
PENDING
$2,500
May 6, 2026Unknown CLASS - 1
ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED ON THE 2ND 3RD 4TH FLS INSTALLATION OF A/C SPILT UNIT DUCTLESS SYSTEM AND WIRING FOR SINGLE RMS NEW EMT PIPES FEED BOXES FOR POWER THRU OUT. 27-3018(B) ALL WORK MUST B
#39187492L
Feb 9, 2027
PENDING
$2,500
May 6, 2026Unknown CLASS - 1
FAILURE TO GROUND ELECTRICAL SYSTEMS. OBSERVED IN THE BASEMENT THAT THE MAIN BUILDING WATER GROUND CLAMP IS DEUTERATED COMPLETELY CORRODED POTENTIAL FOR FIRE ELECTRICAL SHOCK. EC 250.4 250.25 GROUNDING ELECTROD
#39187494P
Feb 9, 2027
PENDING
$4,800
May 6, 2026Construction CLASS - 1
OBSERVED THROUGH OUT THE BUILDING SPRINKLER HEADS OBSTRUCTED WHICH IS CONTRARY TO CODE SECTION BC 903.3.3, REPAIR AND/REPLACE
#39187524R
Feb 16, 2027
PENDING
$2,500
May 6, 2026Construction CLASS - 1
OBSERVED IN F & R TRADING STORE IN THE BASEMENT OPEN ENDED GAS LINE AND A FUTURE ON GAS LINE. ALSO A SPRINKLER HEAD NOT INSTALLED PROPERLY. BOXES OBSTRUCTING SPRINKLER HEADS SPRAY WHICH IS CONTRARY TO CODE SECT
#39187523P
Feb 16, 2027
PENDING
$2,500
May 6, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ATOI I WAS GRANTED ACCESS TO SUBJECT LOCATION WHERE I OBSERVED CONCRET CEILING JOIST AT BASEMENT EXPOSURE 1 IN NEED OF REPAIR ALSO WOODEN CEILING JOIST AT 2
#39187511H
Feb 25, 2027
PENDING
$2,500
May 6, 2026Construction CLASS - 1
OBSERVED ON THE FOURTH FLOOR SPRINKLER HEAD INSTALLED BACKWARDS. IN THE BATHROOM SINKS DOESN'T CLOSE. ON THE FIFTH FLOOR RADIATOR IS NOT SUPPORT PROPERLY AND SPRINKLER HEAD DAMAGED WHICH IS CONTRARY TO CODE SEC
#39187525Z
Feb 16, 2027
PENDING
$2,500
May 6, 2026Unknown CLASS - 1
FAILURE TO PROVIDE/MAINTAIN SUFFICIENT ACCESS/WORK SPACE ABOUT ELECTRICAL EQUIPMENT. OBSERVED IN THE BASEMENT THAT THE SERVICE EQUIPMENT IS BLOCKED AND COVERED WITH BOXES AND COMBUSTIBLE MATERIALS. POTENTINAL F
#39187495R
Feb 9, 2027
PENDING
$1,600
May 6, 2026Unknown CLASS - 1
UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN BATH RMS ON 3RD 4TH 5TH FLS NO GFCI INSTALLED WHERE SINKS ARE LOCATED. ALSO EXPOSED WIR
#39187493N
Feb 9, 2027
PENDING
$1,600
May 6, 2026Construction CLASS - 1
OBSERVED IN THE BASEMENT BOILER ROOM BEING USED AS A STORAGE ROOM. ALSO, STORAGE AROUND GAS METER LOCATED IN CHINESE RESTAURANT. IN BASEMENT USING JIM CAPS ON WASTE LINES. THROUGHOUT THE BUILDING PIPE PENETRATI
#39187526K
Feb 16, 2027
PENDING
$2,500
Apr 14, 2026Construction CLASS - 1
OBSERVED THE DROP LADDER LANDING AREA TO THE EXTERIOR FIRE ESCAPE ON BOWERY ST SIDE OF THE BUILDING IS OBSTRUCTED BY A SECURED TARP AT AWNING & VENDOR ITEMS AT SIDEWALK., REPAIR AND/REPLACE
#39184514J
Feb 25, 2027
PENDING
$2,500
Apr 14, 2026Construction CLASS - 2
OBSERVED APPROX. 85% OF THE EXISTING CUBICLES USED AS SLEEPING QUARTERS WAS REMOVED FROM THE 4TH & 5TH FLOOR WITHOUT A PERMIT., OBTAIN ALL PERMITS; CONTACT OBMSWO@BUILDINGS.NYC.GOV FOR RE-INSPECTION.
#39186914H
Feb 25, 2027
PENDING
$1,250
Apr 14, 2026Construction CLASS - 2
OBSERVED APPROX. 85% OF THE CUBICLES AT 4TH & 5TH FLOOR WAS COMPLETELY REMOVED CONTRARY TO C OF O # 35211. FLOOR IS OCCUPIED & NO ACTIVE PERMIT ON FILE FOR CHANGE OF USE. STOP ALL WORK AT 4TH & 5TH FLOOR ONLY.
#39184486L
Feb 25, 2027
PENDING
$1,250
Apr 14, 2026Construction CLASS - 2
OBSERVED DEBRIS STORED AT INTERIOR OF 4TH FLOOR, BATHROOM CEILING REMOVED AT 3RD & 4TH FLOOR EXPOSING THE WOODEN FLOORING JOIST. FLOORS ARE OCCUPIED., REPAIR AND/OR REPLACE
#39184515L
Feb 25, 2027
PENDING
$1,250
Sep 11, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER; OBSERVED CEILINGS ON 2ND, 3RD, AND 4TH FLOORS REMOVED IN COMMON BATHROOMS, W/ CEILING JOISTS SUPPORTED BY 4X4'S AND SCREWED ON 2X4'S ATTACHED TO 4X4 BEAMS.
#39160034Y
Jan 8, 2026
DEFAULT
$25,000
Aug 4, 2025Construction CLASS - 1
ATOI OBSERVED CEILINGS ON SECOND, THIRD AND FOURTH FLOOR REMOVED IN COMMON BATHROOMS. COMPROMISED CEILING JOISTS SUPPORTED BY 4X4 BEAMS AND SCREWED ON 2X4'S ATTACHED TO 4X4 BEAMS. 2X4 TOP PLATES ARE LAID FLAT T
#39155953Z
Mar 1, 2027
PENDING
$2,530
DOB (23)
IssuedViolationStatus
Sep 17, 2026CONSTRUCTION
OBSERVED PARAPET WALL AT ROOF CORNER OF EXPO 2/3 WITH LARGE CRACK AND ALSO MUTIPLE CHIMNEYS AT EXPO 2 WITH MISSING MORTAR. CONDTIONS ARE EXISITNG OVER PUBLIC SIDEWALK AND OVER STORES CAUSING OVERHEAD HAZARD. ENGINEERS REPORT FOR STRUCTURAL STABILITY REQUIRED.
#26-02227
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#01899
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#01898
DOB VIOLATION - ACTIVE
Sep 11, 2025CONSTRUCTION
ENGINEERS REPORT(STRUCTURAL STABILITY) REQUESTED DUE TO CEILINGS ON 2ND, 3RD, AND 4TH FLOORS REMOVED IN COMMON BATHROOMS, WITH CEILING JOISTS SUPPORTED BY 4X4'S AND SCREWED ON 2X4'S ATTACHED TO 4X4 BEAMS. 2X4 TOP PLATES HAVE ALSO BEEN LAID FLAT MAKING IT INADEQUATE FOR LOAD DISTRIBUTION.
#25-02119
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#40952
DOB VIOLATION - ACTIVE
Jan 1, 2009LOCAL LAW 62/91 - BOILERS

#03584
DOB VIOLATION - ACTIVE
Jan 1, 2009LOCAL LAW 62/91 - BOILERS

#03583
DOB VIOLATION - ACTIVE
Jan 3, 2008LOCAL LAW 62/91 - BOILERS

#03492
DOB VIOLATION - ACTIVE
Jan 3, 2008LOCAL LAW 62/91 - BOILERS

#03491
DOB VIOLATION - ACTIVE
Jan 19, 2007LOCAL LAW 62/91 - BOILERS

#03574
DOB VIOLATION - ACTIVE
Jan 19, 2007LOCAL LAW 62/91 - BOILERS

#03575
DOB VIOLATION - ACTIVE
Jan 6, 2006LOCAL LAW 62/91 - BOILERS

#03406
DOB VIOLATION - ACTIVE
Jan 6, 2006LOCAL LAW 62/91 - BOILERS

#03405
DOB VIOLATION - ACTIVE
Jan 31, 2005LOCAL LAW 62/91 - BOILERS

#03964
DOB VIOLATION - ACTIVE
Jan 31, 2005LOCAL LAW 62/91 - BOILERS

#03963
DOB VIOLATION - ACTIVE
Mar 19, 2003LOCAL LAW 62/91 - BOILERS

#00443
DOB VIOLATION - ACTIVE
Mar 26, 2002LOCAL LAW 62/91 - BOILERS

#00484
DOB VIOLATION - ACTIVE
Feb 27, 2001LOCAL LAW 62/91 - BOILERS

#00453
DOB VIOLATION - ACTIVE
Feb 7, 2000LOCAL LAW 62/91 - BOILERS

#00436
DOB VIOLATION - ACTIVE
Jul 13, 1999CONSTRUCTION

#MTF03FE
DOB VIOLATION - ACTIVE
Jul 13, 1999CONSTRUCTION

#MTF02FE
DOB VIOLATION - ACTIVE
Jul 13, 1999CONSTRUCTION

#MTF01FE
DOB VIOLATION - ACTIVE
Mar 16, 1999LOCAL LAW 62/91 - BOILERS

#00432
DOB VIOLATION - ACTIVE
DOB NOW Safety (33)
IssuedViolationStatus
Jul 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Jul 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Jul 8, 2026AEUHAZ FTC-AEU-HAZ
Active
Jul 8, 2026AEUHAZ FTC-AEU-HAZ
Active
Jun 15, 2026AEUHAZ FTC-AEU-HAZ
Active
Jun 15, 2026AEUHAZ FTC-AEU-HAZ
Active
Jun 15, 2026AEUHAZ FTC-AEU-HAZ
Active
Jun 15, 2026AEUHAZ FTC-AEU-HAZ
Active
Jun 15, 2026AEUHAZ FTC-AEU-HAZ
Active
Jun 15, 2026AEUHAZ FTC-AEU-HAZ
Active
Jun 15, 2026AEUHAZ FTC-AEU-HAZ
Active
Jun 15, 2026AEUHAZ FTC-AEU-HAZ
Active
Jun 15, 2026AEUHAZ FTC-AEU-HAZ
Active
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 3)
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Jan 1, 2009Boiler LL6291
Active
Jan 1, 2009Boiler LL6291
Active
Jan 3, 2008Boiler LL6291
Active
Jan 3, 2008Boiler LL6291
Active
Jan 19, 2007Boiler LL6291
Active
Jan 19, 2007Boiler LL6291
Active
Jan 6, 2006Boiler LL6291
Active
Jan 6, 2006Boiler LL6291
Active
Jan 31, 2005Boiler LL6291
Active
Jan 31, 2005Boiler LL6291
Active
Mar 19, 2003Boiler LL6291
Active
Mar 26, 2002Boiler LL6291
Active
Feb 27, 2001Boiler LL6291
Active
Feb 7, 2000Boiler LL6291
Active
Mar 16, 1999Boiler LL6291
Active
HPD (79) · C 32 · B 20 · A 25
IssuedClassViolationCorrect by
Nov 22, 2024I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Nov 17, 2025I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
May 19, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SPRING BALANCE AT 4TH WINDOW FROM WEST AT NORTH WALL AT PUBLIC HALL, 4th STORYJun 23, 2026
May 19, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SPRING BALANCE AT 8TH WINDOW FROM NORTH AT EAST WALL AT PUBLIC HALL, 4th STORYJun 23, 2026
May 19, 2026A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 4th STORYAug 22, 2026
May 19, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 4th STORYJun 23, 2026
May 19, 2026C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL WASH BASIN 1ST FROM WEST AT COMMUNITY BATHROOM, 4th STORYMay 25, 2026
May 19, 2026A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE CERAMIC TILE FLOOR AT COMMUNITY BATHROOM, 4th STORYAug 22, 2026
May 19, 2026C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR ''MISSING APPROX 12 SQ FEET AT B-ROOM 61'' LOCATED AT B-ROOM, 3rd STORY, 2nd B-ROOM FROM NORTH AT EASTMay 25, 2026
May 19, 2026A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT COMMUNITY BATHROOM, 4th STORYAug 22, 2026
May 19, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT COMMUNITY BATHROOM, 4th STORYJun 23, 2026
May 19, 2026B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WALLS ERECTED WITH SHEETROCK AND STUDS OBSTRUCTION EGRESS AT FIRE ESCAPE AT BUILDING FRONT AT PUBLIC HALL, 3rd STORYJun 23, 2026
May 19, 2026C§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING AT COMMUNITY BATHROOM, 4th STORYMay 25, 2026
May 12, 2026BApt 189 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE ROOM LOCATED AT B-ROOM 189, 5th STORY, 2nd B-ROOM FROM WEST AT NORTHJun 16, 2026
May 12, 2026CApt 97 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXOPESED ELECTRIC WIRES IN THE ROOM LOCATED AT B-ROOM 97, 4th STORY, 2nd B-ROOM FROM WEST AT NORTHMay 18, 2026
May 12, 2026CApt 80 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AT ENTRANCE IN THE ROOM LOCATED AT B-ROOM 80, 3rd STORY, 8th B-ROOM FROM EAST AT SOUTHMay 26, 2026
May 4, 2026B§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF LIGHT FIXTURES HANGING FROM EXPOSED WIRING AT CEILING THROUGHOUT OPEN AREAS AT 4TH AND 5TH STORIESJun 8, 2026
Apr 29, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 2, 2026
Apr 17, 2026C§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING KNEE BRACE (SUPPORT BRACKET) UNDER 2ND STORY BALCONY AT BUILDING FRONT AT FIRE ESCAPEApr 23, 2026
Apr 17, 2026C§ 12 M/D LAW DISCONTINUE THE STORAGE OF COMBUSTIBLE MATERIAL CONSISTING ON OF AN EXCESSIVE AMOUNT OF BOXES AND A PROPANE TANK AT BOILER ROOMApr 23, 2026
Apr 17, 2026C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT COMMUNITY BATHROOM, 4th STORYApr 23, 2026
Mar 23, 2026CApt 81 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM 81, 3rd STORY, 1st B-ROOM FROM EAST AT SOUTHMar 20, 2026
Mar 23, 2026CApt 189 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM 189, 5th STORY, 3rd B-ROOM FROM WEST AT NORTHMar 20, 2026
Mar 23, 2026C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LEADING TO BOILER ROOM AT BASEMENT LOCKEDMar 29, 2026
Mar 16, 2026CApt 189 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM 189, 5th STORY, 2nd B-ROOM FROM EAST AT SOUTHMar 16, 2026
Sep 23, 2025A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT COMMUNITY BATHROOM, 5th STORYDec 27, 2025
Sep 23, 2025C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT COMMUNITY BATHROOM, 3rd STORYSep 29, 2025
Sep 23, 2025B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT ALL WALLS AT PUBLIC HALL, 4th STORYOct 28, 2025
Sep 23, 2025A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT COMMUNITY BATHROOM, 4th STORYDec 27, 2025
Sep 23, 2025B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SOUTH WALL AT PUBLIC HALL STAIRS, 5th STORYOct 28, 2025
Sep 23, 2025A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOOR AT PUBLIC HALL, 5th STORYDec 27, 2025
Sep 23, 2025C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT PUBLIC HALL, 3rd STORYSep 29, 2025
Sep 23, 2025B§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .. AT COMMUNITY BATHROOM, 5th STORYOct 28, 2025
Sep 23, 2025B§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN AT COMMUNITY BATHROOM, 5th STORYOct 28, 2025
Sep 23, 2025C567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GOct 19, 2025
Sep 23, 2025A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT SOUTH WALL AT PUBLIC HALL STAIRS, 5th STORYDec 27, 2025
Sep 23, 2025C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT COMMUNITY BATHROOM, 4th STORYSep 29, 2025
Sep 23, 2025B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT ALL WALLS AT COMMUNITY BATHROOM, 4th STORYOct 28, 2025
Sep 23, 2025A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AT COMMUNITY BATHROOM, 4th STORYDec 27, 2025
Sep 23, 2025A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS AT PUBLIC HALL, 4th STORYDec 27, 2025
Sep 23, 2025C567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GOct 19, 2025
Sep 23, 2025A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOORS AT PUBLIC HALL, 4th STORYDec 27, 2025
Sep 23, 2025A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT COMMUNITY BATHROOM, 3rd STORYDec 27, 2025
Sep 8, 2025B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FEET AT CEILING AT COMMUNITY BATHROOM, 5th STORY ORIGINAL VIOLATION 17883367 ISSUED 30-APR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).Oct 13, 2025
Aug 5, 2025B§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN SINK AT COMMUNITY BATHROOM, 4th STORYSep 9, 2025
Aug 5, 2025C§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AT COMMUNITY BATHROOM, 3rd STORYAug 11, 2025
Aug 5, 2025C§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AT COMMUNITY BATHROOM, 4th STORYAug 11, 2025
Jun 10, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCK TO BASEMENTJun 16, 2025
Jun 5, 2025C567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GJul 1, 2025
Jun 5, 2025A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE ... AT COMMUNITY BATHROOM, 4th STORYSep 8, 2025
Jun 5, 2025B§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET AT ALL WATER CLOSETS AT COMMUNITY BATHROOM, 4th STORYJul 10, 2025
Jun 4, 2025A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Sep 7, 2025
May 9, 2025A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOOR AT PUBLIC HALL, 4th STORYAug 12, 2025
May 9, 2025C§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE BOTTOM FACIA PLATE AT STACK AT BUILDING FRONT AT FIRE ESCAPE, 2nd STORYMay 15, 2025
May 9, 2025A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOOR AT PUBLIC HALL, 3rd STORYAug 12, 2025
Feb 24, 2025A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS AND CEILING AT COMMUNITY BATHROOM, 3rd STORYMay 30, 2025
Feb 24, 2025B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENTS MATERIALS AT ALL WALLS AND CEILING AT COMMUNITY BATHROOM, 3rd STORYMar 31, 2025
Feb 24, 2025C§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE AT FRONT BOTTOM FACIA PLATE AT FIRE ESCAPE, 2nd STORYMar 2, 2025
Apr 1, 2024A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jul 5, 2024
Nov 2, 2023CApt 40 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT B-ROOM 40, 3rd STORYNov 28, 2023

Showing 60 of 79. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Sep 18, 2026DOBIMMEDIATE EMERGENCY: REMEDY: INSTALLATION OF SIDEWALK SHED AT EXPO 2 (LOCATED AT 237-241 GRAND.STREET) APPROXIMATELY 75 LINEAR FEET + ADDITIONAL.ADJACENT PROPERTY 5 LINEAR.FEET TOTAL = 80 LINEAR FEETClosed
Sep 17, 2026DOBCONSTRUCTION: OBSERVED PARAPET WALL AT ROOF CORNER OF EXPO 2/3 WITH LARGE CRACK AND ALSO MUTIPLE CHIMNEYS AT EXPO 2 WITH MISSING MORTAR. CONDTIONS ARE EXISITNG OVER PUBLIC SIDEWALK AND OVER STORES CAUSING OVERHEAD HAZARD. ENGINEERS REPORT FOR STRUCTURAL STABILITY REQUIRED.Open
Sep 17, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED PARAPET WALL WITH LARGE CRACK ON CORNER OF EXPO 2 AT EXPO 3 SIDE. MULTIPLE CHIMNEY STACK ALSO MISSING MORTAR HOLDING THE BRICKS TOGETHER. AREA OF PARAPET/CHIMNEYS OVERHANGS PUBLIOpen
Jul 30, 2026DOB SafetyAEUHAZ: Open
Jul 30, 2026DOB SafetyAEUHAZ: Open
Jul 8, 2026DOB SafetyAEUHAZ: Open
Jul 8, 2026DOB SafetyAEUHAZ: Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 11:02 AM ET. BBL 1003040016.