Staten Island · Block 18 · Lot 74 · 10301

237 Daniel Low Terrace

4 floors · 6 apartments · 10,104 sq ft · built 1900 · class S5 · owner of record: Redzep Kosic, As Trustee

35open violations
$3,750ECB/OATH penalties owed
6HPD class C (immediately hazardous)
63dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 63 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 79 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 307 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 794 days
Next cycle year 2028

Open violations

ECB / OATH (3) · $3,750 owed
IssuedViolationHearingBalance
Oct 9, 2026Construction CLASS - 1
ATOI OBSERVED THE REQUIRED EXIT PASSAGEWAY LOCATED WITHIN THE DRIVEWAY AT EXP#02 OBSTRUCTED BY A CHAIN-SECURED METAL GATE, PREVENTING FREE AND UNOBSTRUCTED EGRESS FROM THE BUILDING TO THE PUBLIC WAY. SAID CONDI
#39207407N
Dec 16, 2026
PENDING
$2,500
Oct 8, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING EXTERIOR IN A SAFE AND CODE-COMPLIANT CONDITION, ATOI OBSERVED MULTIPLE VERTICAL AND STAIR-STEP CRACKS ALONG EXTERIOR MASONRY WALLS, DETERIORATED FACADE SURFACES, MISSING AND DAMAGE
#39207395P
Dec 16, 2026
PENDING
$1,250
Oct 6, 2017Construction CLASS - 2
WOKR W/O A PERMIT. NOTED: AT TIME OF INSPECTION THERE ARE BUSINESS AWNINGS ABOVE 2 LOCATIONS. BOTH ARE APPROX 3FT HEIGHT & A TOTAL LENGTH ABOUT 50FT LONG. THE AWNING WRAPS AROUND THE CORNER OF THE BLDG AT CORSO
#35290997R
Mar 14, 2018
ADMIT/IN-VIO
$0
DOB (4)
IssuedViolationStatus
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#20880
DOB VIOLATION - ACTIVE
Mar 1, 2013LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
#17031
DOB VIOLATION - ACTIVE
Jan 1, 2009LOCAL LAW 62/91 - BOILERS

#26080
DOB VIOLATION - ACTIVE
Jan 3, 2008LOCAL LAW 62/91 - BOILERS

#26135
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
Mar 1, 2013Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
Active
Jan 1, 2009Boiler LL6291
Active
Jan 3, 2008Boiler LL6291
Active
Mar 19, 2003Boiler LL6291
Active
Mar 26, 2002Boiler LL6291
Active
Feb 27, 2001Boiler LL6291
Active
Mar 16, 1999Boiler LL6291
Active
HPD (20) · C 6 · B 11 · A 3
IssuedClassViolationCorrect by
Oct 23, 2019B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WITH FIRE RETARDANT MATERIAL FROM 1ST TO 4TH STORY ALL WALLS AND CEILINGNov 27, 2019
Jun 3, 2019CApt 3R · § 27-2056.7 ADM CODE -CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNERJul 1, 2019
Apr 23, 2019CApt 3R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMay 14, 2019
Apr 23, 2019BApt 3R · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ELECTRIC OUTLET ATY NORTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMay 28, 2019
Apr 23, 2019BApt 3R · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER PLATE AT ELECTRIC OUTLET AT SOUTTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 3R, 36th STORY, 1st APARTMENT FROM SOUTH AT WESTMay 28, 2019
Apr 23, 2019CApt 3R · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE INNER GLASS PANE AT LOWER SASH AT WINDOW AT WEST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 3R, 36th STORY, 1st APARTMENT FROM SOUTH AT WESTMay 1, 2019
Apr 23, 2019BApt 3R · § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 3R, 36th STORY, 1st APARTMENT FROM SOUTH AT WESTMay 28, 2019
Apr 23, 2019AApt 3R · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ACUSTIC DROP CEILING IN THE BATHROOM LOCATED AT APT 3R, 36th STORY, 1st APARTMENT FROM SOUTH AT WESTJul 27, 2019
Apr 23, 2019CApt 3R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMay 14, 2019
Apr 23, 2019BApt 3R · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). - MISING LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMay 28, 2019
Apr 23, 2019BApt 3R · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMay 28, 2019
Apr 23, 2019BApt 3R · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING OUTLET COVER PLATE AT WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMay 28, 2019
Apr 22, 2019CApt 3R · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 7; WG TO REPLACE = 0; WG TO REPAIR = 2; IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APAMay 20, 2019
Apr 22, 2019BApt 3R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL, SOUTH WALL IN THE 5th ROOM FROM NORTH LOCATED AT APT 3R, 36th STORY, 1st APARTMENT FROM SOUTH AT WESTMay 27, 2019
Apr 22, 2019BApt 3R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 3R, 36th STORY, 1st APARTMENT FROM SOUTH AT WESTMay 27, 2019
Apr 22, 2019CApt 3R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) WEST WALL, 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE KITCHEN LOCATED AT APT 3R, May 20, 2019
Aug 12, 2016ASECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYNov 15, 2016
Aug 12, 2016BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING CEILING AT PUBLIC HALL, 1st STORYSep 16, 2016
Aug 12, 2016ASECTION 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORYNov 15, 2016
Aug 12, 2016BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING CEILING AT PUBLIC HALL, 3rd STORYSep 16, 2016

Issued in the last 120 days

DateSourceWhatNow
Oct 9, 2026ECBConstruction: ATOI OBSERVED THE REQUIRED EXIT PASSAGEWAY LOCATED WITHIN THE DRIVEWAY AT EXP#02 OBSTRUCTED BY A CHAIN-SECURED METAL GATE, PREVENTING FREE AND UNOBSTRUCTED EGRESS FROM THE BUILDING TO THE PUBLIC WAY. SAID CONDIOpen
Oct 8, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING EXTERIOR IN A SAFE AND CODE-COMPLIANT CONDITION, ATOI OBSERVED MULTIPLE VERTICAL AND STAIR-STEP CRACKS ALONG EXTERIOR MASONRY WALLS, DETERIORATED FACADE SURFACES, MISSING AND DAMAGEOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 5:49 AM ET. BBL 5000180074.

Look up another building