2 floors · 4,024 sq ft · built 1928 · class K4 · owner of record: 2366 Westchester Realty Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 775 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 22, 2021 | Plumbing CLASS - 1 I OBSERVED IN BASEMENT GAS BEING SUPPLIED TO HOT WATER HEATER. ALSO ON FIRST FLOOR IN ZEREGA DELI & GROCERY GAS BEING SUPPLIED FOR COMMERCIAL COOKING WITHOUT HAVING GAS AUTHORIZATION AND CERTIFICATION BY DOB. P #39038063Y | Jun 4, 2021 IN VIOLATION | $1,250 |
| Mar 22, 2021 | Construction CLASS - 1 WORK WITHOUT A PERMIT I OBSERVED IN THE BASEMENT NEW GAS WORK WITH FRESH SEALANT ON PIPE INSTALLED FOR THE HOT WATER HEATER WORK WAS DONE 100 PERCENT UTILITY LOCKED GAS, OBTAIN PERMIT #39038064X | Jun 4, 2021 IN VIOLATION | $2,500 |
| Mar 22, 2021 | Plumbing CLASS - 1 FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED I OBSERVED NEW GAS WORK WAS INSTALLED IN BASEMENT FOR HOT WATER HEATER NO PERMITS THEREFORE NO TEST, PERFORM TEST #39038066J | Jun 4, 2021 IN VIOLATION | $2,500 |
| Mar 22, 2021 | Construction CLASS - 1 I OBSERVED IN THE BASEMENT GAS LINE GOING TO HOT WATER HEATER NOT BEING SUPPORTED PROPERLY. RELIEF VALVE ON HOT WATER HEATER WAS NOT PIPED OUT. GREECE TRAP HAD AN OPEN VENT. SEWER LINES WAS OPEN IN BASEMENT AND #39038065H | Jun 4, 2021 IN VIOLATION | $625 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 10) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 11:30 PM ET. BBL 2038340044.