6 floors · 150 apartments · 116,586 sq ft · built 1974 · class D1 · owner of record: 235 West 22nd Street
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 47 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 116,586 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Energy audit and retro-commissioning (2032) Likely applies Local Law 87 · Calendar year 2032 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 772). Agency page | Dec 31, 2032 in 2239 days | Next due 2032 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 5, 2026 | Construction CLASS - 2 OBSERVED WORK BEING PERFORMED AT THE PARKING STRUCTURE LEVEL INVOLVING STRUCTURAL SHORING AND STABILIZATION OF AREAS WHERE THE CONCRETE APPEARS TO BE COMPROMISED. NO VALID PERMIT ON FILE FOR THE WORK BEING PERF #39179337L | May 14, 2026 IN VIOLATION | $0 |
| Jun 4, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATING CONDITIONS CITED IN NOV#35299117K ISSUED 1/26/2018 PURSUANT TO 28-201.2;28-204.4;1R #35546797Z | Apr 14, 2022 IN VIOLATION | $1,250 |
| Jun 4, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATING CONDITIONS CITED IN NOV#35321388K ISSSUED 4/16/2018 PURSUANT TO 28-201.2;28-204.4;1 #35546795P | Apr 14, 2022 IN VIOLATION | $1,250 |
| Jun 4, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATING CONDITIONS CITED IN NOV#35299118M ISSUED 1/26/2018 PURSUANT TO 28-201.2;28-204.4;1R #35546796R | Apr 14, 2022 IN VIOLATION | $1,250 |
| Jun 4, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATING CONDITIONS CITED IN NOV#35321391L ISSUED 4/16/2018 PURSUANT TO 28-201.2;28-204.4;1R #35546793L | Apr 14, 2022 IN VIOLATION | $1,250 |
| Jun 4, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATING CONDITIONS CITED IN NOV#35321392N ISSUED 4/16/2018 PURSUANT TO 28-201.2;28-204.4;1R #35546791H | Apr 14, 2022 IN VIOLATION | $1,250 |
| Jun 4, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATING CONDITIONS CITED IN NOV#35321393P ISSUED 4/16/2018 PURSUANT TO 28-201.2;28-204.4;1R #35546792J | Apr 14, 2022 IN VIOLATION | $1,250 |
| Apr 16, 2018 | Construction CLASS - 1 SEC. 907.2.8 FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE ATAPT#6Z. CLASS'J'. PREVIOUS VIO#35299117K. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY. #35321388K | Jan 31, 2019 IN VIOLATION | $0 |
| Jan 26, 2018 | Construction CLASS - 1 BC907.2.8.FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE.CLASS"J",REM:DISCONTINUE ILLEGAL USE. #35299117K | Mar 15, 2018 WRITTEN OFF | $0 |
| Jan 26, 2018 | Plumbing CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF A SYSTEMOF AUTOMATIC SPRINKLERS WHERE IS REGISTERED AS PER BC 903.2 AND AC27-954 FOR TRANSIENT USE.REM:DISCONTINUE ILLEGAL USE. #35299118M | Mar 15, 2018 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 5, 2026 | CONSTRUCTION STRUCTURAL STABILITY REPORT REQUESTED FOR A PARKING LOT STRUCTURE WHERE TEMPORARY SHORING IS INSTALLED. THE SHORED SECTION SHOWS DEGRADED AND COMPROMISED CONCRETE. THIS CONDITION MAY AFFECT THE STRUCTURAL INTEGRITY OF THE AREA. EVALUATION BY A LICENSED STRUCTURAL ENGINEER IS RECOMMENDED TO DETERMINE #26-00676 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #02549 | DOB VIOLATION - ACTIVE |
| Sep 15, 2017 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST #00544 | DOB VIOLATION - ACTIVE |
| Sep 15, 2017 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST #00543 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #01975 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #01973 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #01974 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #01976 | DOB VIOLATION - ACTIVE |
| Aug 29, 1995 | LOCAL LAW 62/91 - BOILERS #11890 | DOB VIOLATION - ACTIVE |
| Mar 18, 1994 | LOCAL LAW 62/91 - BOILERS #16108 | DOB VIOLATION - ACTIVE |
| Mar 18, 1993 | LOCAL LAW 62/91 - BOILERS #16108 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jun 18, 2026 | Parking Structures FTC-PS-UNSAFE 202606 | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 25, 2024 | Parking Structures FTF-PS-INITL Failure to file sub cycle 1A compliance report by 12/31/2023 | Active |
| May 20, 2019 | Elevators EVCAT5 | Active |
| May 20, 2019 | Elevators EVCAT5 | Active |
| Sep 15, 2017 | Elevators EVCAT1 | Active |
| Sep 15, 2017 | Elevators EVCAT1 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Aug 29, 1995 | Boiler LL6291 | Active |
| Mar 18, 1994 | Boiler LL6291 | Active |
| Mar 18, 1993 | Boiler LL6291 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 6:07 PM ET. BBL 1007720018.