Manhattan · Block 1331 · Lot 17 · 10022

235 East 57 Street

18 floors · 94 apartments · 105,749 sq ft · built 1960 · class D4 · owner of record: 235 East 57th St. Apartment Corp.

38open violations
$12,500ECB/OATH penalties owed
1HPD class C (immediately hazardous)
43dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 43 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 43 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 59 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 105,749 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 164 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 164 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 287 days
Registered through 2027-09-01
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $14,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 826 days
Filing window not open yet
Energy audit and retro-commissioning (2031) Likely applies
Local Law 87 · Calendar year 2031
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1331). Agency page

Dec 31, 2031
in 1869 days
Next due 2031

Open violations

ECB / OATH (3) · $12,500 owed
IssuedViolationHearingBalance
Jul 28, 2025Construction CLASS - 2
AT TIME OF INSPECTION OF 19 STORY FACADE JOB WHERE WORKER WAS INJURED CARRYING BRICK DOWN BASEMENT STAIRS BLOCKED WITH TRASH CREATING HAZARDOUS CONDITIONS WHEN WORKER FELL INJURED HIS BACK AND RIGHT LEG TAKEN T
#39542926N
Nov 12, 2026
IN VIOLATION
$5,000
Jul 28, 2025Construction CLASS - 1
AT TIME OF INSPECTION WHERE INCIDENT WAS REPORTED OF A WORKER MOVING BRICK DOWN STAIRS WHEN WORKER INJURED THEIR RIGHT LEG AND BACK AND TAKEN TO HOSPITAL AT 10AM. CONTRACTOR FAILED TO NOTIFY DEPARTMENT IMMEDIAT
#39542950N
Oct 2, 2025
IN VIOLATION
$5,000
Jul 28, 2025Construction CLASS - 1
AT TIME OF INSPECTION WHERE INCIDENT WAS REPORTED OF A WORKER MOVING BRICK DOWN STAIRS WHEN WORKER INJURED THEIR RIGHT LEG AND BACK AND TAKEN TO HOSPITAL AT 10AM. SITE SAFETY MANAGER FAILED TO NOTIFY DEPARTMENT
#39542967J
Oct 30, 2025
IN VIOLATION
$2,500
DOB (3)
IssuedViolationStatus
Feb 17, 2024HAZARDOUS CONDITION (FACADE)
CYCLE 9C UNSAFE REPORT FILED
#911503
DOB VIOLATION - ACTIVE
Jul 15, 2011ELEVATOR

#9027/388622
DOB VIOLATION - ACTIVE
Dec 27, 1989CONSTRUCTION

#B3PS01
VIOLATION UNSERVED ECB-ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Feb 17, 2024Facades FISPHAZ
CYCLE 9C UNSAFE REPORT FILED
Active
HPD (33) · C 1 · B 23 · A 9
IssuedClassViolationCorrect by
Jun 27, 2011ASECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 18th STORYSep 30, 2011
Jun 27, 2011BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 18th STORYAug 1, 2011
May 18, 2011ASECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR , AT PUBLIC HALL, 1st STORYAug 21, 2011
May 18, 2011ASECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 19th STORYAug 21, 2011
May 18, 2011BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 19th STORYJun 22, 2011
Jun 30, 2008CSECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT GATE REAR EAST FIRE PASSAGEWAY.Jul 6, 2008
Jun 30, 2008AApt 3B · D26-10.01 ADM CODE REFIT WINDOWS AT LIVINGROOM 3 STY SOUTHEAST APT 3B. LOCATED AT APT 3BOct 3, 2008
Jun 30, 2008BApt 3B · D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE DOOR TO 3 STY SOUTHEAST APT 3B. LOCATED AT APT 3BAug 4, 2008
Jun 30, 2008AD26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT APT THROUGHOUT 3 STY SOUTHEAST APT 3B.Oct 3, 2008
Jun 30, 2008BApt 3B · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALL AT EAST AT LIVINGROOM 3 STY SOUTHEAST APT 3B. LOCATED AT APT 3BAug 4, 2008
Jun 30, 2008BApt 18 · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK FRONT ROOM 18 STY FRONT WEST APT 18. LOCATED AT APT 18Aug 4, 2008
Apr 2, 2007ASECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SOUTH WEST SECTION MECHANICAL VENT NOT OPERATING AT ROOFJul 11, 2007
Sep 9, 2005BApt 15E · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 15E, 14th STORY, 3rd APARTMENT FROM EAST AT SOUTHOct 19, 2005
Sep 9, 2005BApt 15E · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 15E, 14th STORY, 3rd APARTMENT FROM EAST AT SOUTHOct 19, 2005
Nov 24, 2003BSECTION 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT MISSING BRICK AT NORTH SIDE OF BUILDINGJan 3, 2004
Nov 24, 2003BApt 18K · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 18K, 18th STORYJan 3, 2004
Nov 24, 2003BApt 18-K · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE ENTIRE APARTMENT LOCATED AT APT 18-K, 18th STORYJan 3, 2004
May 26, 1998BSECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL COMPACTOR ROOM 18 STY PUBLIC HALL.Jul 13, 1998
May 26, 1998BApt 18H · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILINGS THROUGHOUT 18 STY SOUTHEAST APT 18H. LOCATED AT APT 18HJul 13, 1998
May 26, 1998BApt 18H · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MOISTURE PENETRATING WALLS & CEILINGS THROUGHOUT SOUTHEAST APT 18H. LOCATED AT APT 18HJul 13, 1998
May 26, 1998BApt 18H · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR SOUTHEAST ROOM 18 STY SOUTHEAST APT 18H. LOCATED AT APT 18HJul 13, 1998
Mar 17, 1998BApt 18H · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING CLOSET EAST ROOM UPPER LEVEL 18 STY SOUTHEAST DUPLEX APT 18H LOCATED AT APT 18HMay 4, 1998
Mar 17, 1998BApt 18H · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MOISTURE PENETRATING CEILING EAST ROOM UPPER LEVEL 18 STY SOUTHEAST DUPLEX APT 18H LOCATED AT APT 18HMay 4, 1998
Mar 17, 1998BApt 18H · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING EAST ROOM UPPER LEVEL 18 STY SOUTHEAST DUPLEX APT 18H LOCATED AT APT 18HMay 4, 1998
Mar 17, 1998BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT CEILING COMPACTOR ROOM 19 STY PUBLIC HALLMay 4, 1998
Aug 5, 1997BApt 18H · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK CEILING UPPER LEVEL THRU OUT 18 STY SOTUHEAST APT 18H. LOCATED AT APT 18HSep 22, 1997
Aug 5, 1997BApt 18H · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING EAST ROOM 18 STY SOUTHEAST APT 18H. LOCATED AT APT 18HSep 22, 1997
Aug 5, 1997BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEILING WALL UTILITY ROOM PUBLIC HALL 18 STY.Sep 22, 1997
Aug 5, 1997BApt 18H · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALL THRU OUT 18 STY SOUTHEAST APT 18H. LOCATED AT APT 18HSep 22, 1997
Oct 18, 1994AApt 18H · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING UPPER EAST ROOM & CLOSET 17 STY DUPLEX APT 18H , SECTION '' ''Feb 3, 1995
Jun 4, 1991BApt 16F · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 15 STY NORTHWEST APT 16F WONG. , SECTION '' ''Jul 22, 1991
Jun 4, 1991AApt 16F · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOODEN SADDLE CENTER NORTH ROOM 15 STY NORTHWEST APT 16F. , SECTION '' ''Sep 20, 1991
Jun 4, 1991AApt 16F · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL BY RADIATOR NORTHWEST ROOM 15 STY NORTHWEST APT 16F. , SECTION '' ''Sep 20, 1991

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 1:26 AM ET. BBL 1013310017.