4 floors · 41,600 sq ft · built 1930 · class O7 · owner of record: Bedford Tilden Associates, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 54 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 41,600 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 175 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 175 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 17 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 419 days | Next cycle year 2027 |
None open.
None open.
| Issued | Violation | Status |
|---|---|---|
| Sep 23, 2026 | Parking Structures FTF-PS-INITL Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 4, 2009 | A | Apt 2 · SECTION 27-2005 ADMIN. CODE: REFIT ENTRANCE DOOR IN THE KITCHEN LOCATED AT APT 2, 2nd STORY | Nov 7, 2009 |
| Aug 4, 2009 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF TORN AND LOOSE LINOLEUM FLOOR IN THE 1st BEDROOM FROM WEST LOCATED AT APT 2, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILING KITCHEN AND IN THE BATHROOM LOCATED AT APT 2, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE AND OR MAKE OPERABLE UPPER AND LOWER WINDOW SASHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT RADIATOR IN THE 1st BEDROOM FROM WEST LOCATED AT APT 2, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | A | Apt 2 · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE AND OR MAKE OPERABLE WINDOW LATCH IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY | Nov 7, 2009 |
| Aug 4, 2009 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL AND FLOOR TILE IN THE BATHROOM LOCATED AT APT 2, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | Apt 2 · SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS HOT WATER WASHBASIN IN THE BATHROOM LOCATED AT APT 2, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | A | Apt 2 · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING ELECTRICAL WALL OUTLET COVERS IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY | Nov 7, 2009 |
| Aug 4, 2009 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE WALL CABINETS IN THE KITCHEN LOCATED AT APT 2, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE METAL BASE SINK CABINET IN THE KITCHEN LOCATED AT APT 2, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR JAMB ENTRANCE IN THE KITCHEN LOCATED AT APT 2, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT APT 2, 2nd STORY | Sep 8, 2009 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 23, 2026 | DOB Safety | Parking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 7, 2026, 12:01 AM ET. BBL 3051350001.