11 floors · 400,000 sq ft · built 1938 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 47 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 400,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 774). Agency page | Dec 31, 2034 in 2969 days | Next due 2034 |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | On file | Cycle 10 filing on record: SWARMP (2025-07-14) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 23, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.FROM 9TH FLOOR TO 1ST FLOOR ALL 1 CORRIDOR DOORS NOT CLOSING PROPERLY.ALSO FROM 9TH TO1ST EXIT TO STAIR DOOR ALL HAVE KNOBS AND NO PUSH BAR.REM:COMPLY WITH #35732358X | May 21, 2026 POP/IN-VIO | $0 |
| Apr 23, 2026 | Construction CLASS - 2 REISSUE:35720692N FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ROOF LEVEL ROOFING MATERIAL HAS BUBBLES,BLISTER THROUGHOUT.REM:COMPLY WITH CODE. #35732357Y | May 21, 2026 POP/IN-VIO | $0 |
| Apr 23, 2026 | Construction CLASS - 2 28-301.1 REISSUE:35720694R MISCELLANEOUS VIO-GAS METER ROOM HAS NO VENTILATION.REM:COMPLY WITH CODE. #35732356M | May 21, 2026 POP/IN-VIO | $0 |
| Jul 3, 2025 | Construction CLASS - 2 28-302.1. REISSUE #35684886X DATE OF ISSUE: 09-27-2024. FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM PER P115.6(1968 CODE) FGC APPENDIX E(E4)(2014 CODE). AT THE TIME OF INSPECTION OBSERVED AND NOTED AT CELL #35720694R | Aug 28, 2025 POP/IN-VIO | $0 |
| Jul 3, 2025 | Construction CLASS - 2 REISSUE #35684888J DATE OF ISSUE: 09-27-2024. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED AT ROOF LEVEL(THE ROOF ABOVE THE 10TH FLOOR). THERE ARE LARGE BU #35720692N | Aug 28, 2025 POP/IN-VIO | $0 |
| Sep 27, 2024 | Construction CLASS - 2 28-301.1. RE-ISSUE #35674736L. FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM PER P115.6(1968 CODE), FGC APPENDIX E(E4)(2014 CODE). NOTED;OBSERVED AT CELLAR, THE GAS METER ROOM HAS NO FRESH AIR VENTILATION. R #35684886X | Oct 30, 2024 POP/IN-VIO | $0 |
| Sep 27, 2024 | Construction CLASS - 2 RE-ISSUE #35674738P. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVED AT ROOF LEVEL(THE ROOF ABOVE THE 10 FLOOR), THERE ARE LARGE BUSTERS AT VARIOUS LOCATION, THROUGHOUT. REMEDY: REPAIR AN #35684888J | Oct 30, 2024 POP/IN-VIO | $0 |
| May 23, 2023 | Construction CLASS - 2 28-301.1 REISSUE#35643325P NOTED:THE GAS METER ROOM AT CELLAR LEVEL DOES NOT HAVE NATURAL OR MECHANICAL VENTILATION INSTALLED.REM:COMPLY WITH NOTICE OF VIOLATION. #35674736L | Sep 14, 2023 POP/IN-VIO | $0 |
| May 23, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:THE ROOF OVER THE 10TH FLOOR LEVEL GYMNASIUM HAS LARGE BLISTERS IN VARIOUS AREASTHROUGHOUT.REM:REPAIR AND/OR REPLACE. #35674738P | Sep 14, 2023 POP/IN-VIO | $0 |
| May 6, 2022 | Construction CLASS - 2 28-301.1 REISSUE35561086H FAILURE TO PROVIDE VENTILATION TO GAS METER RM PER P115.6@BSMT LEVEL IN GAS METER RM NO FRESH AIR VENTILATION AS PER CODE.COMPLY W/NOTICE OF VIOLATION.COMPLY W/NOTICE OF VIOLATION. #35643325P | Sep 1, 2022 POP/IN-VIO | $0 |
| May 7, 2021 | Construction CLASS - 2 28-301.1 REISSUE35495251J DOI4.27.20 VENTILATION TO GAS METER RM PER P115.6(1968CODE) FGC APPENDIXE(E4)(2019CODE) NOTE:@BSMT LEVEL IN GAS METER RM NO FRESH AIR VENTILATION AS PER CODE.COMPLY W/NOTICE OF V. #35561086H | Aug 12, 2021 POP/IN-VIO | $0 |
| Apr 27, 2020 | Construction CLASS - 2 BC283011-REISSUE 35415552K.FAILURE TO PROVIDE VENTILATION TO GAS METERROOM PER P115.6(1968 CODE)FGC APPENDIX E(E4)(2014 CODE)NOTE:AT BASEMENT LEVEL IN GAS METER ROOM NO FRESH AIR VENTILATION AS PER CODE.REMEDY: #35495251J | Aug 13, 2020 POP/IN-VIO | $0 |
| Apr 15, 2019 | Construction CLASS - 2 28-302.1 REISSUED#35297398R FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM PER P 115.6(1968 CODE) FGC APPENDIX E(E4)(2014 CODE). NOTE AT BASEMENT LEVEL IN GAS METER ROOM NO FRESH AIR VENTILATION OR NATURAL AI #35415552K | Jun 27, 2019 POP/IN-VIO | $0 |
| Feb 14, 2018 | Construction CLASS - 2 REISSUED #35234945Z,3-16-17. NO VENTILATION OR NATURAL AIR INTAKE FOR GAS METER ROOM. REMEDY: NEED PROPER VENTILATION OR NATURAL AIR INTAKE FOR GAS ROOM. #35297398R | May 3, 2018 POP/IN-VIO | $0 |
| Mar 16, 2017 | Construction CLASS - 2 REISSUE#35177489X FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER.NO VENTILATION OR NATURAL AIR INTAKE FOR GAS METER ROOM AT CELLAR LEVEL CONTRARY TO 27-766. REMEDY: COMPLY W/SUMMONS PROVIDE VENTILATION. #35234945Z | Apr 27, 2017 POP/IN-VIO | $0 |
| Jun 6, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: NO FRESH AIR VENT IN GAS METER ROOM. @ CELLAR GAS METER ROOM, NO FRESH VENTILATION VENT OBSERVED. RE-ISSUE ECB# 35119906M. REM: COMPLY W/ NOV. #35177489X | Sep 15, 2016 POP/IN-VIO | $0 |
| Jan 29, 2015 | Unknown CLASS - 2 27-766. REISSUE #35094227M NO FRESH AIR INLET (FAI) AT CELLAR GAS METER ROOM. RMDY: PROVIDE FAI. #35119906M | Mar 19, 2015 POP/IN-VIO | $0 |
| Apr 15, 2014 | Unknown CLASS - 2 27-766. RE-ISSUE # 35015680M. NO FRESH AIR INLET (FAI). AT CELLAR GAS METER ROOM. REMEDY: PROVIDE F.A.I. #35094227M | Jun 19, 2014 POP/IN-VIO | $0 |
| Apr 3, 2013 | Unknown CLASS - 2 SEC. 27-766. REISSUE 34941678J. NO FRESH AIR VENTILATION GAS METER RM.REMEDY: PROVIDE VENTILATION. #35015680M | May 16, 2013 POP/IN-VIO | $0 |
| Apr 17, 2012 | Unknown CLASS - 2 SEC. 27-766 REISSUE 34923280K,34847784M FAILURE TO PROVIDE F.A.I. IN GAS METER ROOM BASEMENT. REMEDY: PROVIDE F.A.I. #34941678J | Jun 14, 2012 POP/IN-VIO | $0 |
| Jul 20, 2011 | Unknown CLASS - 2 SEC. 27-766. REISSUE #34847784M. NO FRESH AIR VENT. AT CELLAR LEVEL GAS METER ROOM, NO FRESH AIR VENTILATION. REMEDY: PROVIDE FRESH AIR VENT. #34923280K | Sep 15, 2011 POP/IN-VIO | $0 |
| Apr 16, 2010 | Construction CLASS - 2 FAILURE TO MAINTAIN OBSERVED NO FRESH AIR VENTILATION IN GAS METER ROOM REM: PROVIDE VENTILATION #34847784M | Jul 15, 2010 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 13, 2016 | CONSTRUCTION THE BORO-COMM HAS ORDER ALL WORK STOPPED FOR APPLICATION #122058290, THE APPLICANT OF RECORD HAS WITHDRAWN AS A PERMIT HOLDER - STOP WORK REMEDY: STOP WORK, PROVIDE ALL REQUIRED INFORMATION FORTHWITH #0402MS | DOB VIOLATION - ACTIVE |
| Mar 10, 2016 | CONSTRUCTION BORO-COMM #0401EH | DOB VIOLATION - ACTIVE |
| Mar 31, 2008 | EMERGENCY POWER #NRF00263 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #00528 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Feb 22, 2022 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 | Active |
| Mar 31, 2008 | Emergency Power FTF-EL-ENRF | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 11:03 AM ET. BBL 1007740019.