Brooklyn · Block 3269 · Lot 18 · 11237

232 Stanhope Street

3 floors · 6 apartments · 4,875 sq ft · built 1931 · class C2 · owner of record: Migdal10 Management 2010 Llc

35open violations
$12,500ECB/OATH penalties owed
18HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 69 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-30 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (8) · $12,500 owed
IssuedViolationHearingBalance
Jul 22, 2026Construction CLASS - 2
FAILURE TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIO# 35506723J, FILE A CERTIFICATE OF CORRECTION
#39197224Y
Oct 7, 2026
PENDING
$1,250
Jun 1, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR SUMMONS # 35506723J ISSUED 2/14/23., FILE A CERTIFICATE OF CORRECTION
#39190646M
Aug 12, 2026
IN VIOLATION
$1,250
Feb 16, 2023Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENT.NOTEAT TIME OF INSPECTION,OBSERVED DUST ON FLOORS,RAILINGS,WALL IN HALLWAYS AND STAIRS OF BUILDING.REMEDY:MAINTAIN ADEQUATE CONSTRUCTION HOUSEKE
#35657143L
Mar 3, 2025
IN VIOLATION
$2,500
Feb 14, 2023Unknown CLASS - 1
FAILURE TO NOTIFY DEPT 72 HRS PRIOR TO COMMENCEMENT OF WORK.AT TIME OF INSPECTION OBSERVED 5 CONSTRUCTION WORKERS PERFORMING CONSTRUCTION WORK ASSOCIATED WITH APPLICATION #B08034594 IN COMMON STAIRCASE OF BUILD
#35506719R
Apr 26, 2023
IN VIOLATION
$1,250
Feb 14, 2023Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:IN STAIRCASE OF OCCUPIED MULTIPLE DWELLING CONSTRUCTION WORK IN PROGRESS UNDER JOB #B08034594.STORAGE OF SHEETROCK ON 1ST FL HALLWAYS 2ND & 3RD FLS LOADED W
#35506720Y
Apr 18, 2024
IN VIOLATION
$1,250
Feb 14, 2023Construction CLASS - 1
28-104.7.7 FAILURE TO FILE TRI PRIOR TO COMMENCEMENT OF WELDING.NOTED:REPLACEMENT OF METAL WELDED STAIRS FROM 2ND TO 3RD FLS UNDER JOB #B08034594 FORMS & DESIGNATED OPERATION SUBJECT TO CONTROLLED INSPECTIONS O
#35506723J
Apr 26, 2023
IN VIOLATION
$2,500
Feb 14, 2023Construction CLASS - 1
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS.NOTED:AT 1ST TO 2ND FLOOR IS ORIGINAL WOOD STAIRCASE.METAL WELDED STAIRCASE FROM 1ND TO 3RD FL JOB #B08034594 INDICATES REPAIRS TO STAIRCASE OF BUILDING
#35506721X
Apr 18, 2024
IN VIOLATION
$2,500
Oct 19, 2016Unknown CLASS - 2
UNAPPROVED,UNSAFE,UNSUITABLE,ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE. EXPOSE ELECTRICAL FIXTURE WIRING IN USE. EXPOSE ELECTRICAL FIXTURE WIRING ON GROUND FLOOR & BASEMENT.
#35201732Y
Dec 5, 2016
ADMIT/IN-VIO
$0
DOB (3)
IssuedViolationStatus
Aug 2, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00045
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#16344
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#33010
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Aug 2, 2023AEUHAZ FTC-AEU-HAZ
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
HPD (26) · C 18 · B 8 · A 0
IssuedClassViolationCorrect by
Feb 20, 2025CApt 3L · § 27-2044, 2041.1 HMC: §238 MDL and 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTMar 6, 2025
Sep 6, 2023BApt 3L · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE TOP HINGE AT DOOR IN THE ENTRANCE LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOct 11, 2023
Sep 6, 2023CApt 3L · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOct 2, 2023
Sep 6, 2023BApt 3L · § 27-2005 HMC: REFIT LOWER SASH AT 1ST WINDOW FROM EAST IN THE 1st ROOM FROM NORTH LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOct 11, 2023
Sep 6, 2023BApt 3L · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOct 11, 2023
Sep 6, 2023BApt 3L · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOct 11, 2023
Sep 6, 2023CApt 3L · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOct 2, 2023
Jul 3, 2023CApt 3R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHJul 29, 2023
Sep 22, 2022B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 8 SQ FT AT WEST WALL AT CELLAR ORIGINAL VIOLATION 15173747 ISSUED 20-MAY-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).Oct 27, 2022
Aug 11, 2022BApt 2R · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 4 SQUARE FEET CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 15105465 ISSUED 10-APR-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(aSep 15, 2022
May 2, 2022CApt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM EAST AT SOUTH WALL, NORTH WALL IN THE 3rd ROOM FROM NORTH LOCATED May 26, 2022
May 2, 2022CApt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1May 26, 2022
May 2, 2022CApt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 2nd DOOR FROM EAST AT SOUTH WALL, 2nd DOOR FRAME FROM EAST AT SOUTH WALL IN THE 1st ROMay 26, 2022
May 2, 2022CApt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) BASEBOARD AT EAST WALL, 1st DOOR FRAME FROM EAST AT SOUTH WALL, NORTH WALL, EAST WALL May 26, 2022
May 2, 2022CApt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL, 1st WINDOW FRAME FROM WEST AT NORTH WALL, 1st WINDOW FRAME FROMay 26, 2022
Apr 13, 2022CApt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM EAST AT SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2R, 2May 7, 2022
Apr 13, 2022CApt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM EAST AT SOUTH WALL, WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT May 7, 2022
Jan 18, 2022BApt 1L · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 4 SQ FT AT SOUTH WALL IN THE 6th ROOM FROM NORTH AT EAST LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 14550361 ISSUED 14-SEP-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRAFeb 22, 2022
Nov 29, 2021BApt 2R · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 4 SQ.FT AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 14462023 ISSUED 25-JUL-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2Jan 3, 2022
Sep 20, 2021CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE AT BASEMENTOct 16, 2021
Sep 20, 2021CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT BASEMENTOct 16, 2021
Sep 16, 2021CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS YARDOct 12, 2021
Aug 19, 2021CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT CELLARSep 14, 2021
Aug 19, 2021CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RAT EXCRETA AT SOUTH YARDSep 14, 2021
Aug 2, 2021CApt 1R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS AT BUILDING FRONT YARDAug 28, 2021
Dec 10, 2020CApt 3R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 5, 2021

Issued in the last 120 days

DateSourceWhatNow
Jul 22, 2026ECBConstruction: FAILURE TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIO# 35506723J, FILE A CERTIFICATE OF CORRECTIONOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 1:41 PM ET. BBL 3032690018.