6 floors · 19 apartments · 14,734 sq ft · built 1910 · class C4 · owner of record: 300-302 East 119 Sthousing Development E Tc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 431 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-18 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 1, 2026 | Construction CLASS - 2 ACCESS GAINED, VIOLATING CONDITIONS HAVE BEEN CORRECTED; HOWEVER, A CERTIFICATE OF CORRECTIONS HAS NOT BEEN OBTAINED FOR CLASS 1 VIOLATION #39095379L ISSUED 9/20/2023 CITING DEFECTS AT STUCCO WALL AND VERTICAL #39206348H | Dec 10, 2026 PENDING | $1,250 |
| Sep 20, 2023 | Construction CLASS - 1 AT THE TIME OF INSPECTION I HAVE OBSERVED A BULGING STUCCO WALL AT EXP#4 IN DANGER OF FALLING BELOW ONTO PUBLIC SIDEWALK BETWEEN BUILDINGS AND FEW HORIZONTAL & VERITCAL CRACKS ALONGSIDE 2 AVENUE AT PARAPET WALL #39095379L | Nov 30, 2023 IN VIOLATION | $0 |
| Jun 25, 2020 | Elevators CLASS - 1 CEASE USE ITEM. EXCESSIVE GAP BETWEEN BRAKE PADS AND DRUM AT LEAST 75%. BRAKE TEST REQUIRED IF NEW PADS ARE INSTALLED AT 125% CAPACITY. RE GROOVE SHEAVE. EMERGENCY STOP SWITCH IN CAR INOPERATIVE. REPAIR. PROVID #39024553J | Aug 13, 2020 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 20, 2023 | CONSTRUCTION AT THE TIME OF INSPECTION I HAVE OBSERVED A BULGING STUCCO WALL AT EXP#4 IN DANGER OF FALLING BELOW ONTO PUBLIC SIDEWALK BETWEEN BUILDINGS AND FEW HORIZONTAL & VERITCAL CRACKS ALONGSIDE 2 AVENUE AT PARAPET WALL HEIGHT. #23-02650 | DOB VIOLATION - ACTIVE |
| Sep 16, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00083 | DOB VIOLATION - ACTIVE |
| Jan 26, 2018 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST #11148 | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST #11034 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #12116 | DOB VIOLATION - ACTIVE |
| Mar 18, 1994 | LOCAL LAW 62/91 - BOILERS #05941 | DOB VIOLATION - ACTIVE |
| Mar 18, 1993 | LOCAL LAW 62/91 - BOILERS #05941 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 29, 2025 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Report | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Sep 16, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 26, 2018 | Elevators ACC1 | Active |
| Jan 3, 2017 | Elevators ACC1 | Active |
| Nov 14, 2016 | Elevators ACC1 | Active |
| Mar 18, 1994 | Boiler LL6291 | Active |
| Mar 18, 1993 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 20, 2026 | B | Apt 6B · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 24, 2026 |
| Jul 20, 2026 | A | Apt 6B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING SOUTH AND EAST WALLS IN THE FOYER LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 23, 2026 |
| Jul 20, 2026 | A | Apt 6B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING NORTH AND EAST WALLS IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 23, 2026 |
| Jul 20, 2026 | A | Apt 6B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 23, 2026 |
| Jul 20, 2026 | A | Apt 6B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 23, 2026 |
| Jul 20, 2026 | B | Apt 6B · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 24, 2026 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 1, 2026 | ECB | Construction: ACCESS GAINED, VIOLATING CONDITIONS HAVE BEEN CORRECTED; HOWEVER, A CERTIFICATE OF CORRECTIONS HAS NOT BEEN OBTAINED FOR CLASS 1 VIOLATION #39095379L ISSUED 9/20/2023 CITING DEFECTS AT STUCCO WALL AND VERTICAL | Open |
| Jul 20, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 20, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING SOUTH AND EAST WALLS IN THE FOYER LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 20, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING NORTH AND EAST WALLS IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 20, 2026 | HPD A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 20, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 20, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Jul 20, 2026 | HPD A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT VESTIBULE DOOR | Closed |
| Jul 20, 2026 | HPD A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT BUILDING ENTRANCE DOOR | Closed |
| Jul 20, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT VESTIBULE DOOR | Closed |
| Jul 20, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT BUILDING ENTRANCE DOOR | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)