Manhattan · Block 1540 · Lot 14 · 10128

231 East 94 Street

4 floors · 39,272 sq ft · built 1926 · class G1 · owner of record: 231-243 East 94th Street Llc

16open violations
$18,750ECB/OATH penalties owed
0HPD class C (immediately hazardous)
46dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 46 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 46 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 39,272 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 167 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 167 days
Annual filing

Open violations

ECB / OATH (7) · $18,750 owed
IssuedViolationHearingBalance
May 29, 2026Construction CLASS - 2
NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE TO MAINTAIN VIOLATION #39104508K ISSUED 1/27/2024 CITING CRACKS AT PARAPET ROOF AND MASONRY ACROSS FACADE 1ST AND 2ND STORY., FILE A CERTIFICATE OF CORRE
#39190323H
Aug 6, 2026
DEFAULT
$6,250
Jun 21, 2024Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. NOTE:-RESPONDENT FAILURE TO COMPLY WITH PREVIOUS VIOLATION #35682426X AND 35682427H DATED 03/20/2024, AND DOB VIOLATION #032024LL10801MK, WHICH REQUIR
#35685171R
Aug 5, 2025
IN VIOLATION
$0
Mar 20, 2024Construction CLASS - 1
28-323.1 FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION.AS NOTED:ON AN ACTIVE PARKING STRUCTURE CONSISTING OF 4 LEVEL AT HT AND ABOVE LL 3 LEVEL ELEVATOR OPERATED)OBSERVED SPALLING CONCRETE/EXPOSED REB
#35682426X
May 30, 2024
DEFAULT
$6,250
Mar 20, 2024Construction CLASS - 1
28-323.8 AND RCNY 103-13(5)FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKETHE BUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO THE PREVIOUS OF THE ADMIN CODE AFTER UNSAFE NOTIFICATION FILED BY QPSI#UNPS-M0000132 D
#35682427H
May 30, 2024
DEFAULT
$6,250
Jan 27, 2024Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING: THE MASONRY FRONT FACADE IS BOWED AT THE WEST SIDE 1ST AND 2ND FLOOR, THERE ARE CRACKS AT VARIOUS LOCATIONS UP TO THE PARAPET LEVEL. THE INTERIOR SLABS HAVE SPALLING MISSING CEMENT
#39104508K
Nov 13, 2024
IN VIOLATION
$0
Aug 30, 2021Elevators CLASS - 1
PROVIDE CAR GATE AND GATE SWITCH TO COMPLY WITH APPENDIX K3 OF THE NYCBC.
#39046742X
Dec 16, 2021
IN VIOLATION
$0
Aug 30, 2021Elevators CLASS - 1
PROVIDE CAR GATE AND GATE SWITCH TO COMPLY WITH APPENDIX K3 OF THE NYCBC.
#39046741Y
Nov 10, 2022
ADMIT/IN-VIO
$0
DOB (9)
IssuedViolationStatus
Oct 30, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00027
DOB VIOLATION - ACTIVE
Apr 17, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00034
DOB VIOLATION - ACTIVE
Mar 20, 2024CONSTRUCTION
EMER WORK ORD. EXPOSED-REBAR/STEEL BEAM FROM CEILING 3 LEV) SPALLING CONCRETE EXP/STEEL BEEAM FROM CEILING 4 FL LEV.SEVERAL LOC CAUSING IMMEDIATE HAZARD TO TRAFFIC. REMEDY:OWNER TO RETAIN A NYS REG DESIGN PROF TO IMMED INSTALL OF SAFETY MEASURES.ALL WORK REPORTED AS DAILY PROGRESS REP TO STRUCTURE@B
#LL10801MK
DOB VIOLATION - ACTIVE
Jan 29, 2024IMMEDIATE EMERGENCY
PROVIDE SIDEWALK SHED AT ENTIRE FRONT PF PREMISES TO SAFEGUARD THE PU BLIC AND PROPERTY
#18123
DOB VIOLATION - ACTIVE
Jan 27, 2024CONSTRUCTION
THE BRICK VANEER IS CRACKED,LOOSE,MISSING MORTAR IN VARIOUS LOCATIONS. THE INTERIOR CONCRETE SLABS ARE DEFECTIVE ON ALL FLOORS IN VARIOUS LOCATIONS WITH REBAR SHOWING CONCRETE MISSING SPALLING AT TIME OF INSPECTION.
#24-00229
DOB VIOLATION - ACTIVE
Mar 27, 2001ELEVATOR
1F4486
#9444136017
DOB VIOLATION - ACTIVE
Mar 27, 2001ELEVATOR

#9444136016
DOB VIOLATION - ACTIVE
Mar 27, 2001ELEVATOR
1F4487
#9444136016
DOB VIOLATION - ACTIVE
Sep 9, 1993CONSTRUCTION

#BPR03
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Oct 30, 2024AEUHAZ FTC-AEU-HAZ
Active
Apr 17, 2024AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 15, 2026, 2:32 AM ET. BBL 1015400014.

Look up another building