4 floors · 8 apartments · 6,500 sq ft · built 1900 · class C1 · owner of record: 230 Sackett Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 60 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-07 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 12, 1995 | Construction Hazardous WORK WITHOUT A PERMIT HAZADOUS REAR EXTERIOR STAIRWELL AND PARTION OF MAIN STRUCTURE HAVE BEEN UNDERWIRE OR EXCAVATED REMEDY:OBTAIN ALL PERMITS FILE TECHMICAL REPORT FROM PE TO DOB FAILURE TO MAINTAIN WOODEN LA #34125935X | Aug 14, 1995 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 25, 1995 | CONSTRUCTION #06C01 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #38980 | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 2, 2022 | B | Apt 4R · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 7, 2022 |
| Jun 2, 2022 | C | Apt 4R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2022 |
| Jun 2, 2022 | B | Apt 4R · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER SASH WINDOW AT SOUTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 7, 2022 |
| Jun 2, 2022 | B | Apt 4R · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 7, 2022 |
| Jun 2, 2022 | B | Apt 4R · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 7, 2022 |
| Jun 2, 2022 | C | Apt 4R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 28, 2022 |
| Jun 2, 2022 | B | Apt 4R · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 7, 2022 |
| Jun 2, 2022 | B | Apt 4R · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW COUNTER BALANCE UPPER SASH AT NORTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 7, 2022 |
| Jun 2, 2022 | B | Apt 4R · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 7, 2022 |
| Jul 10, 2017 | B | Apt 4L · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 14, 2017 |
| Jul 10, 2017 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Oct 13, 2017 |
| Jun 6, 2017 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Sep 9, 2017 |
| Jun 6, 2017 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY | Jun 14, 2017 |
| Sep 14, 2015 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS MINIMUM REQUIRED, LIGHT FIXTURE PRESENT | Oct 19, 2015 |
| Sep 19, 2006 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL CEILING 4TH STORY AT PUBLIC HALL | Oct 29, 2006 |
| Sep 7, 2006 | B | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR KNOB AND STRIKE PLATE AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Oct 17, 2006 |
| Sep 7, 2006 | B | Apt 2L · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 2L, 2nd STORY | Oct 17, 2006 |
| Sep 7, 2006 | A | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILINGS AT PUBLIC HALL | Dec 16, 2006 |
| May 4, 2004 | B | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING ALL STY PUBLIC HALL AT PUBLIC HALL, 2nd STORY | Jun 13, 2004 |
| Apr 27, 2004 | A | Apt 4-R · SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION HOLE CREATED WITH DOME LIGHT INSTALLED CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4-R, 4th STORY, APARTMENT AT NORTH | Aug 5, 2004 |
| Apr 27, 2004 | B | Apt 4-R · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EVIDENCE OF WATER LEAK CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4-R, 4th STORY, APARTMENT AT NORTH | Jun 6, 2004 |
| Apr 27, 2004 | B | Apt 4-R · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4-R, 4th STORY, APARTMENT AT NORTH | Jun 6, 2004 |
| Nov 7, 2001 | B | Apt 1L · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE, IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, APARTMENT AT EAST | Dec 17, 2001 |
| Dec 29, 1992 | A | SECTION 27-2027 ADM CODE REPAIR THE BROKEN OR DEFECTIVE RAIN LEADER 1 STY REAR WEST | Apr 16, 1993 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 12:25 PM ET. BBL 3003380015.