3 floors · 102,413 sq ft · built 1973 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 68 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 102,413 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 189 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 189 days | Annual filing |
| Energy audit and retro-commissioning (2032) Likely applies Local Law 87 · Calendar year 2032 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3442). Agency page | Dec 31, 2032 in 2260 days | Next due 2032 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-03 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 6, 2026 | Construction CLASS - 2 REISSUE:35719730R FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.WALLS IN APARTMENT EXP#2 SCHOOL YARD RETAINING WALLS LEANING TO YARDHAS CRACKS.REM:COMPLY WITH CODE. #35732929K | Jun 3, 2026 POP/IN-VIO | $0 |
| May 6, 2026 | Construction CLASS - 2 REISSUE:35719736H-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ROOF LEVEL MATERIAL ON ROOF IS DETACHED,BUBBLES THROUGHOUT MISSING FLASHING.REM:COMPLY WITH CODE. #35732374X | Jun 1, 2026 POP/IN-VIO | $0 |
| May 6, 2026 | Construction CLASS - 2 REISSUE:35719738L-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.FACADE IN DETERIORATED CONDITION AND BULGING BRICKS IN SCHOOL DOOR.REM:COMPLY WITH CODE. #35732372M | Jun 1, 2026 POP/IN-VIO | $0 |
| May 6, 2026 | Construction CLASS - 2 REISSUE#35719732K FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.WATER INFILTRATION FROM ROOF THROUGH GYM NAILS,AUDITORIUM STAGE CEILING AREA,STAIRS ETC.REM:COMPLY WITH CODE. #35732927R | Jun 3, 2026 POP/IN-VIO | $0 |
| May 6, 2026 | Construction CLASS - 2 REISSUE#35719735X FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.3RD FLOOR HALLWAY TO STORIES HAS CMU WITH CRACKS.REM:COMPLY WITH CODE. #35732925N | Jun 3, 2026 POP/IN-VIO | $0 |
| May 6, 2026 | Construction CLASS - 2 REISSUE:35719737J-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.SCHOOL YARD LOCATED AT MOFFAT WIKON,POST HAS CORROSION AND MISSING PLATE AT BOTTOM.REM:COMPLY WITH CODE. #35732373Y | Jun 1, 2026 POP/IN-VIO | $0 |
| May 6, 2026 | Construction CLASS - 2 REISSUE#35719731Z FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ELECTRICAL ROOM,GYM HAS WATER INFILTRATION FROM ROOF.REM:COMPLY WITH CODE. #35732928Z | Jun 3, 2026 POP/IN-VIO | $0 |
| May 6, 2026 | Construction CLASS - 2 REISSUE#35719733M FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.CELLAR BOILER PIPES ARE CORRODED WITH CONSTUCTION OVER THE OIL TANKSLEAKING WATER.REM:COMPLY WITH CODE. #35732926P | Jun 3, 2026 POP/IN-VIO | $0 |
| May 9, 2025 | Construction CLASS - 2 REISSUE#35692332Y FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT ELECTRICAL ROOM AND GYM WATER INFILTRATION FROM ROOF THRU CEILINGAND WATER CONTINUOUSLY ONTO BASEMENT.REM:REPAIR AND/OR REPLACE. #35719731Z | Jul 16, 2025 POP/IN-VIO | $0 |
| May 9, 2025 | Construction CLASS - 2 REISSUE#35692246H FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT EXP#2 SCHOOLYARD LOCATED AT MOFFAT & WILSON POST SHOW SIGN OF CORROSION/MISSING AT BOTTOM TOWARD PLATE TO RETAINING WALL.REM:REPAIRS/AN #35719737J | Jul 16, 2025 POP/IN-VIO | $0 |
| May 9, 2025 | Construction CLASS - 2 REISSUE#35692331M FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.WATER INFILTRATION FROM ROOF THROUGH GYM WALLS,AUDITORIUM STAGE CEILING AREA,STAIRS ETC.REM:REPAIR AND/OR REPLACE. #35719732K | Jul 16, 2025 POP/IN-VIO | $0 |
| May 9, 2025 | Construction CLASS - 2 REISSUE#35692247J FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ROOF LEVEL MATERIAL ON ROOF DETACHED,BUBBLING AND OR PARAPET WALLS AREA ETC SOME MISSING FLASHING.REM:REPAIR AND OR REPLACE. #35719736H | Jul 16, 2025 POP/IN-VIO | $0 |
| May 9, 2025 | Construction CLASS - 2 REISSUE#35692245X FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.FACADE IN DETERIATED CONDITION AND BULGING BRICKS IN SCHOOL DOOR.REM:REPAIR AND/OR REPLACE. #35719738L | Jul 16, 2025 POP/IN-VIO | $0 |
| May 9, 2025 | Construction CLASS - 2 REISSUE#35692248L FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT 3RD FLOOR HALLWAY TO STAIR CMV BLOCK SHOW A RUNNING CRACKS TO FLOORS.REM:REPAIR AND/OR REPLACE. #35719735X | Jul 16, 2025 POP/IN-VIO | $0 |
| May 9, 2025 | Construction CLASS - 2 REISSUE#35692244Y FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.WALLS OR APPURTANCE AT EXP#2 SCHOOL YARD RETAINING WALLS ALL STAIRS LEADING TO YARD CRACKS,MISSING MASONRY.REM:MAINTAIN EXTERIOR WALLS OR #35719730R | Jul 16, 2025 POP/IN-VIO | $0 |
| May 9, 2025 | Construction CLASS - 2 REISSUE#35692330K FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT CELLAR BOILER ROOM PIPES IN AREA ARE CORROD WITH CONDENSATION OVER THE OIL TANKS OR LEAKING WATER.REM:REPAIR AND/OR REPLACE. #35719733M | Jul 16, 2025 POP/IN-VIO | $0 |
| Nov 18, 2024 | Construction CLASS - 2 REISSUE:35674672L DATE OF ISSUE:04.12.2023 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER AT THE TIME OF INSPECTION OBSERVED & NOTED FENCE(AT MOFFAT AND WILSON)EXPOSURE#3 AND EXPOSURE#4 FENCE PORT AT RAC #35692246H | Feb 5, 2025 POP/IN-VIO | $0 |
| Nov 18, 2024 | Construction CLASS - 2 REISSUE#35674666P DATE OF ISSUE:04.12.2023 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT THE TIME OF INSPECTION OBSERVED AND NOTED DURING INSPECTION OF SCHOOL WATER PENETRATION THROUGH BASEMENT ON(MO #35692332Y | Feb 5, 2025 POP/IN-VIO | $0 |
| Nov 18, 2024 | Construction CLASS - 2 REISSUE#35674673N DATE OF ISSUE:04.12.2023 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER AT THE TIME OF INSPECTION OBSERVED & NOTED FACADE IN DISREPAIR MULTIPLE AREAS OF BUDGING BRICK DELAMINATION OF BR #35692245X | Feb 5, 2025 POP/IN-VIO | $0 |
| Nov 18, 2024 | Construction CLASS - 2 REISSUE:35674670H DATE OF ISSUE:04.12.2023 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT THE TIME OF INSPECTION OBSERVED & NOTED STAIR WALL A 3RD FLOOR CMU BLOCK WALL HAS RUNNING STAIR CRACK ALONG TO #35692248L | Feb 5, 2025 POP/IN-VIO | $0 |
| Nov 18, 2024 | Construction CLASS - 2 REISSUE#35674674P DATE OF ISSUE:04.12.2023 FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.AT THE TIME OF INSPECTION I OBSERVED AND NOTED RETAINING WALL IN SCHOOL YARD AREA ALL STAIR LEADING TO SCHOOL AND #35692244Y | Feb 5, 2025 POP/IN-VIO | $0 |
| Nov 18, 2024 | Construction CLASS - 2 REISSUE#35674168Z DATE OF ISSUE:04.12.2023 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AT THE TIME OF INSPECTION I OBSERVED & NOTED CELLAR LEVEL & BOILER ROOM THE PIPES ON THE CONDENSATE TANK AND PIPE #35692330K | Feb 5, 2025 POP/IN-VIO | $0 |
| Nov 18, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OBSERVED & NOTEDDURING INSPECTION OF THE SCHOOL THE FOLLOWING AREAS BASEMENT WALL ON (MOFFET SIDE)ELECTRICAL ROOM,GYM WALL,AUDITORIUM STAGE CEILING & STAIR #35692331M | Feb 5, 2025 POP/IN-VIO | $0 |
| Nov 18, 2024 | Construction CLASS - 2 REISSUE#35674671J DATE OF ISSUE:04.12.2023 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT THE TIME OF INSPECTION NOTED & OBSERVED AT ROOF LEVEL GROUND AND PARAPET PAPER & DETACHING BUBBLING/PEELING AW #35692247J | Feb 5, 2025 POP/IN-VIO | $0 |
| Apr 12, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:OBSERVED DURING INSPECTION OF STAIRWELL A 3RD FLOOR CMU BLOCK WALL HAS RUNNING STAIR CRACK ALONG TOP OF IT SPANNING APPROX.6FT IN LENGTH.REM:REPAIR AN #35674670H | Jul 5, 2023 POP/IN-VIO | $0 |
| Apr 12, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:OBSERVED DURING INSPECTION OF CELLAR LEVEL BOILER ROOM,THE PIPES ON THE CONDENSATE TANK AND PIPE OVER THE OIL TANK ARE CONSISTANTLY LEAKING WATER.IN R #35674668Z | Jul 5, 2023 POP/IN-VIO | $0 |
| Apr 12, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED DURING INSPECTION OF FACADE IN DISREPAIR MULTIPLE AREAS OF BUDGING BRICK,DELAMINATION OF BRICK FRONTS,MISSING MORTAR JOINTS,AND CRACKS ALL TH #35674673N | Jul 5, 2023 POP/IN-VIO | $0 |
| Apr 12, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED DURING INSPECTION OF SCHOOL,THE FOLLOWING AREAS BASEMENT WALL ON(MOFFATSIDE),ELECTRICAL ROOM,GYM WALL,AUDITORIUM STAGE CEILING,STAIRWELL TO B #35674667R | Jul 5, 2023 POP/IN-VIO | $0 |
| Apr 12, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.NOTED:OBSERVED DURING INSPECTION OF RETAINING WALL IN SCHOOLYARD AREA ALL STAIR LEADINGINTO SCHOOL AND CONCRETE PLANTERS ARE ALL IN DISREPAIR HAVE CRACKS,MIS #35674674P | Jul 5, 2023 POP/IN-VIO | $0 |
| Apr 12, 2023 | Construction CLASS - 2 REISSUE#35643272K (4/19/22)FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED DURING INSPECTION OF SCHOOL,WATER PENETRATION THROUGH BASEMENT ON (MOFFAT SIDE),IN ELECTRICAL ROOM,1ST FLOOR GYM W #35674666P | Jul 5, 2023 POP/IN-VIO | $0 |
| Apr 12, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:OBSERVED DURING INSPECTION OF FENCE(AT MOFFAT AND WILSON)EXPOSURE#3 AND EXPOSURE#4.FENCE POST AT BASE BROKEN DETACHED AND RUSTED ALL THROUGHOUT.REM:RE #35674672L | Jul 5, 2023 POP/IN-VIO | $0 |
| Apr 12, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:OBSERVED DURING INSPECTION OF ROOF LEVEL GROUND AND PARAPET PAPER IS DETACHING,BUBBLING/PEELING AWAY FROM SUBSTRATE ALL THROUGHOUT.REM:REPAIR AND/OR R #35674671J | Jul 5, 2023 POP/IN-VIO | $0 |
| Apr 19, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT CELLAR THROUGHOUT AND 1ST FLOOR STAIRWELL WALL WITH WATER PENETRATION.REMEDY:COMPLYWITH CODE. #35643272K | Sep 21, 2022 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 8, 2021 | ELEVATOR #9027/711659 | DOB VIOLATION - ACTIVE |
| Oct 16, 2019 | ELEVATOR #9027/662170 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 4:53 PM ET. BBL 3034420001.