Brooklyn · Block 5917 · Lot 16 · 11209

230 73 Street

6 floors · 59 apartments · 48,000 sq ft · built 1963 · class D1 · owner of record: 230 73 Llc

14open violations
$625ECB/OATH penalties owed
2HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 68 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 84 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 48,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 189 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 189 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 799 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-11 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4) · $625 owed
IssuedViolationHearingBalance
Sep 24, 2025Elevators CLASS - 2
REPLACE WORN GIBS WHERE NEEDED. ADJUST LOBBY INTERLOCK. OIL LEKAING INTO TOP OF SHAFT AND CAR TOP. REPALCE DAMAGED BRAKE PIN. ELIMINATE GAP AT TOP OF LEFT BRAKE PAD. MISSING CONTROLLER PRINTS.
#39161465K
Feb 4, 2026
IN VIOLATION
$625
Jan 31, 2023Construction CLASS - 1
UNLAWFUL ACT: FAILURE TO COMPLY WITH THE CEASE USE ORDER BY THE COMMISIONER. DEVICE 3P5861 WAS RETURNED TO SERVICE WITHOUT A REINSPECTION BY THIS DEPARTMENT TO DETERMINE THAT THE CEASE USE CONDITIONS HAVE BEEN
#39078782R
Jun 14, 2023
IN VIOLATION
$0
Jan 24, 2023Elevators CLASS - 1
CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR. CLASS 2 ITEMS: REPLACE WORN GIBS WHERE NEEDED. ADJUST CAB MIRROR. CLEAN GOVERNOR FOR PROPER INSPECTION. ADJUST CAR DOOR CLOSING SPEED. INOPERATIVE CAR PHONE. OI
#39078313Y
Apr 5, 2023
IN VIOLATION
$0
Dec 28, 2022Elevators CLASS - 2
BLIND SPOT MIRROR INSIDE CAR INSUFFICIENT. IN CAR COMMUNICATION INOPERATIVE. CLEAN GOVERNOR ROPE FOR PROPER INSPECTION. REPLACE DOOR GIBS ON LOBBY HOIST WAY DOOR. SADDLE IS WORN. WORM AND GEAR SLIPPING. OIL ON
#39076542Z
Oct 2, 2023
IN VIOLATION
$0
DOB (4)
IssuedViolationStatus
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01851
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01852
DOB VIOLATION - ACTIVE
Apr 1, 2021ELEVATOR

#9028/697645
DOB VIOLATION - ACTIVE
Jun 27, 2018FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00371
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Jul 31, 2018Facades FISPNRF
FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018
Active
Jun 27, 2018AEUHAZ FTC-AEU-HAZ
Active
HPD (3) · C 2 · B 1 · A 0
IssuedClassViolationCorrect by
Sep 11, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT SOUTH FIRE DOOR LEADING TO REAR YARD AT BASEMENTSep 25, 2026
Oct 27, 2025BApt L3 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT THE CAULKING AND GROUT JOINTS OF CERAMIC TILES AND SPLASH BOARD AT EAST WALL AROUND SINK, IN THE KITCHENETTE LOCATED AT CELLAR APT L3, 1st CELLAR APT FROM NORTH AT EAST ORIGINAL VIOLATIONDec 1, 2025
Sep 21, 2023CApt APT1J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPX 35 SQ FT AT CEILING AND WALLS IN THE BATHROOM LOCATED AT APT APT1J, 1st STORY, 3rd APARTMENT FROM EAST AT SOUTHOct 17, 2023

Issued in the last 120 days

DateSourceWhatNow
Sep 11, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT SOUTH FIRE DOOR LEADING TO REAR YARD AT BASEMENTOpen
Jul 10, 2026ECBElevators: UNSECURE ESCAPE HATCH (2.15.1.5.1). REPLACE WORN GIBS WHERE NEEDED. (2.11.11.5.7.)Closed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 9:45 AM ET. BBL 3059170016.