Queens · Block 793 · Lot 29 · 11105

23-63 Steinway Street

3 floors · 2 apartments · 3,075 sq ft · built 1910 · class S2 · owner of record: 23-63 Steinway Realty Llc

8open violations
$71,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
57dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 57 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-10-09 (Accepted). Agency page

Dec 31, 2026
in 57 days
1 of 1 without an accepted 2026 report yet
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 301 days
Required only if the owner doesn't live there
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 788 days
Next cycle year 2028

Open violations

ECB / OATH (7) · $71,250 owed
IssuedViolationHearingBalance
Jul 23, 2026Construction CLASS - 1
AT EXPOSURE 4 ALLEY WAY USED AS FIRE EGRESS FOR REAR IS COMPLETED BLOCKED BY GARBAGE PAILS, CAUSING A SEVERE FIRE AND SAFETY HAZARD THAT CAN RESULT WITH INJURY OR DEATH, REMOVE OBSTRUCTION
#39197426M
Apr 20, 2027
PENDING
$6,250
Mar 11, 2026Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. NOTE: AT TIME OF INSPECTION, OBSERVED/ NOTED - AT CELLAR - EXISTING CONDITIONS CONSISTENT WITH VIO26-00387 ISSUED 2/1/2026; NYSPE REPORT/LETTER NOT SU
#39180357R
Nov 6, 2026
PENDING
$2,500
Mar 11, 2026Construction CLASS - 1
FAILURE TO MAINTAIN IN A CODE-COMPLIANT MANNER. NOTE: - AT TIME OF INSPECTION, OBSERVED/ NOTED: AT CELLAR - 1ST FLOOR JOISTS/ROTTED/IN DISREPAIR & SUPPORTED WITH LALLY COLUMNS; A SEVERE HAZARD DUE TO DYNAMIC LO
#39180356P
Nov 6, 2026
PENDING
$12,500
Mar 4, 2026Construction CLASS - 2
WORK WITHOUT A PERMIT. NOTE: OBSERVED NEW DUCT VENT/EXHAUST HAS BEEN INSTALLED FROM CELLAR TO ROOF AT EXPOSURE 4 OF THIS LOCATION WITHOUT A PERMIT OR DOB APPROVAL., OBTAIN ALL PERMITS
#39179210Y
May 25, 2027
DEFAULT
$6,250
Mar 4, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTE: OBSERVED CELLING IN STATE OF DISREPAIR, SUPPORTED BY TEMPORARY STEEL POSTS NEAR THE STAIRCASE AT CELLAR LEVEL OF THIS LOCATION CREATING A HAZARD., RE
#39179261Y
May 25, 2027
DEFAULT
$6,250
Feb 1, 2026Construction CLASS - 1
SUMMONS ISSUED FOR FAILURE TO PROVIDE UNOBSTRUCTED PASSAGEWAY DUE TO LARGE GAZEBO LIKE STRUCTURE BLOCKING THE REAR EXIT PASSAGEWAY/AREA OF REFUGE OF BUILDING FOR TENANTS., REMOVE OBSTRUCTION
#39175579X
Jun 8, 2027
DEFAULT
$25,000
Feb 1, 2026Construction CLASS - 1
SUMMONS ISSUED FOR WORK WITHOUT A PERMIT DUE TO APPROXIMATELY 20 STEEL GIRDERS INSTALLED ALONG WITH 20 LOLLY COLUMNS AT CELLAR LEVEL OF STRUCTURE. NO PERMITS ON FILE, OBTAIN PERMIT
#39175578Y
Jun 8, 2027
DEFAULT
$12,500
DOB (1)
IssuedViolationStatus
Feb 1, 2026CONSTRUCTION
DOB SUMMONS ISSUED FOR FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER DUE TO THE INSTALLATION OF APPROXIMATELY 20 STEEL GIRDERS AND 20 LOLLY COLUMNS AT CELLAR LEVEL WITH ANY PERMITS
#26-00387
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Jul 23, 2026ECBConstruction: DOB RECORDS SHOW ENGINEER REPORT REQUESTED UNDER DOB VIOLATION VIO26-00387 ISSUED 2/1/26. NONE WERE FILED, COMPLY WITH COMMISSIONER'S ORDERClosed
Jul 23, 2026ECBConstruction: FAILURE TO CERTIFY CORRECTIONS FOR VIOLATION NUMBER 39180356P, FILE A CERTIFICATE OF CORRECTIONClosed
Jul 23, 2026ECBConstruction: AT EXPOSURE 4 ALLEY WAY USED AS FIRE EGRESS FOR REAR IS COMPLETED BLOCKED BY GARBAGE PAILS, CAUSING A SEVERE FIRE AND SAFETY HAZARD THAT CAN RESULT WITH INJURY OR DEATH, REMOVE OBSTRUCTIONOpen
Jul 23, 2026ECBConstruction: FAILURE TO CERTIFY CORRECTION FOR VIOLATION NUMBER 39175579X, COMPLY WITH COMMISSIONER'S ORDERClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 4, 2026, 4:22 PM ET. BBL 4007930029.