5 floors · 97,650 sq ft · built 1931 · class O2 · owner of record: Nyc School Construction Authority
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 59 days | Keep the report on file (not filed with DOB) |
| Energy audit and retro-commissioning (2026) Likely applies Local Law 87 · Calendar year 2026 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 436). Agency page | Dec 31, 2026 in 59 days | Due this year |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2020-10-16 (Accepted). Agency page | Dec 31, 2026 in 59 days | 1 of 1 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 97,650 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 180 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 180 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1155 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 5, 2026 | Construction CLASS - 1 DURING INSPECTION OF AN ACTIVE DEMO SITE WITH SUPPORTED SCAFFOLD IN PLACE, I OBSERVED THAT THERE WAS GUARDRAILS MISSING AT ALL EXPOSURES, THERE WAS ALSO MISSING GUARDRAILS ON THE 2ND STORY DEMO AREA AT THE LEAD #39553804Z | Feb 9, 2027 | $5,000 |
| May 5, 2026 | Construction CLASS - 1 INSPECTION OF AN ACTIVE DEMO OPERATIONS, I OBSERVED A LARGE HILL OF BUILDING RUBBLE/DEBRIS WITH AN EXCAVATOR ON TOP AT EXPOSURE #2 NEAR THE ADJACENT PROPERTY INADEQUATELY PROTECTED OPENING. DEMO PLANS INDICTED #39553802P | Feb 9, 2027 | $2,500 |
| May 5, 2026 | Construction CLASS - 1 DURING INSPECTION OF AN ACTIVE DEMO SITE, I OBSERVED IN DOB RECORDS THAT THERE WAS NO NOTIFICATION TO DOB PRIOR TO THE START OF DEMO OPERATIONS, WHICH IS REQUIRED BY CODE. NOTIFY DOB OF THE START OF DEMO OPERA #39553806M | Feb 9, 2027 | $2,500 |
| May 5, 2026 | Unknown CLASS - 1 BC 3307.4.7 PUBLIC WALKWAY: DURING INSPECTION OF AN ACTIVE DEMO SITE, I OBSERVED THAT THE STORAGE WORK ZONE AT THE CURB SIDE UNDER THE SHED HAD 8 FOOT PLYWOOD FENCE CREATING A TUNNEL FOR THOSE ON THE SIDEWALK & #39553805K | Feb 9, 2027 | $5,000 |
| May 5, 2026 | Construction CLASS - 1 DURING INSPECTION OF AN ACTIVE DEMO SITE, I OBSERVED LARGE AMOUNTS OF RUBBLE AND DEBRIS THROUGHOUT THE SITE. THERE WAS NO DEBRIS DUMPSTER ONSITE, AND THE LARGE AMOUNTS OF DEBRIS FROM THE CELLAR TO THE REMAIN 1S #39553803R | Feb 9, 2027 | $2,500 |
| May 4, 2026 | Construction CLASS - 2 INSPECTION OF AN ACTIVE SCA DEMO SITE, I OBSERVED LARGE AMOUNTS OF BUILDING RUBBER PILED UP INTO A HILL AT EXPOSURE #2 WITH AN EXCAVATOR ON TOP, NEAR THE ADJACENT PROPERTY WALLS AND OPEN SPACE WITH ONLY A CHAIN #39553771L | Feb 9, 2027 | $5,000 |
| Mar 10, 2023 | Elevators CLASS - 2 PROVIDE ACCESS TO THE DEVICE FOR A INSPECTION BY NYCDOB. #39081235P | May 16, 2023 ADMIT/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 2, 2023 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #01224 | DOB VIOLATION - ACTIVE |
| Apr 25, 2016 | ELEVATOR #9028/271578 | DOB VIOLATION - ACTIVE |
| Apr 25, 2016 | ELEVATOR #9028/271577 | DOB VIOLATION - ACTIVE |
| Mar 27, 2008 | ELEVATOR #9444/243874 | DOB VIOLATION - ACTIVE |
| Jun 28, 1993 | LOCAL LAW 62/91 - BOILERS #15817 | DOB VIOLATION - ACTIVE |
| Jun 28, 1993 | LOCAL LAW 62/91 - BOILERS #08934 | DOB VIOLATION - ACTIVE |
| Jun 28, 1993 | LOCAL LAW 62/91 - BOILERS #08935 | DOB VIOLATION - ACTIVE |
| Mar 18, 1992 | CONSTRUCTION KM #2C06 | VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE |
| Oct 31, 1989 | PLUMBING #P022 | DOB VIOLATION - ACTIVE |
| Sep 6, 1988 | ELEVATOR (01)PROPERLY FUSE (51)FILE A BN FOR REFURNISHED CAB,NEW BRAKE, CHANGE OF MODE OF OPERATION AND NEW GOVERNOR INSTALLED AND HAVE SAME TESTED IN THE PRESENCE OF AN INSPECTOR FROM THIS DEPT #13694\1 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| May 2, 2023 | Benchmarking - LL84 FTF-EN-BENCH | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 2, 2026, 3:32 AM ET. BBL 4004360021.