Manhattan · Block 1015 · Lot 7501 · 10036

229 West 43 Street

16 floors · 589,617 sq ft · built 1932 · class RC · owner of record: 229 West 43rd Street Condominium

47open violations
$10,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
99dto Facade inspection report (Cycle 10A)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $517,300 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 99 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 589,617 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1015). Agency page

Dec 31, 2035
in 3334 days
Next due 2035

Open violations

ECB / OATH (1) · $10,000 owed
IssuedViolationHearingBalance
Nov 3, 2026Unknown CLASS - 1
A TERRACOTTA STONE APPROXIMATELY OVER 300 LBS FELL WHEN SUSPENDED 3 FEET HIGH DURING INSTALLATION, HIT A WORKER LEG AND BROKE HIS ANKLE, UPON REQUEST FOR THE STONE INSTALLATION DESIGN DRAWING FROM ENGINEER TO S
#39561484Z
Jan 7, 2027
PENDING
$10,000
DOB (35)
IssuedViolationStatus
Jan 26, 2022HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#909590
DOB VIOLATION - ACTIVE
Oct 22, 2021ELEVATOR

#9027/709209
DOB VIOLATION - ACTIVE
Oct 22, 2021ELEVATOR

#9027/709208
DOB VIOLATION - ACTIVE
Oct 21, 2021ELEVATOR

#9027/709205
DOB VIOLATION - ACTIVE
Oct 21, 2021ELEVATOR

#9027/709204
DOB VIOLATION - ACTIVE
Oct 21, 2021ELEVATOR

#9027/709201
DOB VIOLATION - ACTIVE
Oct 21, 2021ELEVATOR

#9027/709200
DOB VIOLATION - ACTIVE
Oct 21, 2021ELEVATOR

#9027/709199
DOB VIOLATION - ACTIVE
Oct 21, 2021ELEVATOR

#9027/709198
DOB VIOLATION - ACTIVE
Oct 21, 2021ELEVATOR

#9027/709197
DOB VIOLATION - ACTIVE
Oct 21, 2021ELEVATOR

#9027/709196
DOB VIOLATION - ACTIVE
Oct 21, 2021ELEVATOR

#9027/709207
DOB VIOLATION - ACTIVE
Oct 21, 2021ELEVATOR

#9027/709206
DOB VIOLATION - ACTIVE
Oct 14, 2021ELEVATOR

#9027/711100
DOB VIOLATION - ACTIVE
Oct 13, 2020ELEVATOR

#9027/690456
DOB VIOLATION - ACTIVE
Oct 13, 2020ELEVATOR

#9027/690454
DOB VIOLATION - ACTIVE
Oct 13, 2020ELEVATOR

#9027/690455
DOB VIOLATION - ACTIVE
Oct 13, 2020ELEVATOR

#9027/690457
DOB VIOLATION - ACTIVE
Oct 13, 2020ELEVATOR

#9027/690458
DOB VIOLATION - ACTIVE
Oct 13, 2020ELEVATOR

#9027/690460
DOB VIOLATION - ACTIVE
Oct 9, 2020ELEVATOR

#9027/690493
DOB VIOLATION - ACTIVE
Oct 9, 2020ELEVATOR

#9027/690492
DOB VIOLATION - ACTIVE
Oct 7, 2020ELEVATOR

#9027/691878
DOB VIOLATION - ACTIVE
Sep 19, 2019ELEVATOR

#9027/658707
DOB VIOLATION - ACTIVE
Sep 19, 2019ELEVATOR

#9027/658711
DOB VIOLATION - ACTIVE
Sep 19, 2019ELEVATOR

#9027/658709
DOB VIOLATION - ACTIVE
Sep 18, 2019ELEVATOR

#9027/658705
DOB VIOLATION - ACTIVE
Sep 18, 2019ELEVATOR

#9027/658706
DOB VIOLATION - ACTIVE
Sep 18, 2019ELEVATOR

#9027/658700
DOB VIOLATION - ACTIVE
Dec 6, 2018ELEVATOR

#9027/637655
DOB VIOLATION - ACTIVE
Dec 6, 2018ELEVATOR

#9027/637656
DOB VIOLATION - ACTIVE
Dec 5, 2018ELEVATOR

#9027/637651
DOB VIOLATION - ACTIVE
Dec 5, 2018ELEVATOR

#9027/637650
DOB VIOLATION - ACTIVE
Sep 6, 2018FACADE SAFETY PROGRAM

#HAZ87576
DOB VIOLATION - ACTIVE
Feb 10, 2012ELEVATOR

#9028/417817
DOB VIOLATION - ACTIVE
DOB NOW Safety (11)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Aug 29, 2025Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Report
Active
Aug 29, 2025Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Report
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Report
Active
Jan 26, 2022Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Sep 6, 2018Facades FISP
CYCLE 8A UNSAFE REPORT FILED
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Nov 3, 2026ECBUnknown: A TERRACOTTA STONE APPROXIMATELY OVER 300 LBS FELL WHEN SUSPENDED 3 FEET HIGH DURING INSTALLATION, HIT A WORKER LEG AND BROKE HIS ANKLE, UPON REQUEST FOR THE STONE INSTALLATION DESIGN DRAWING FROM ENGINEER TO SOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 11:16 PM ET. BBL 1010157501.

Look up another building