Brooklyn · Block 2688 · Lot 27 · 11222

227 Kingsland Avenue

4 floors · 16 apartments · 11,900 sq ft · built 1930 · class C1 · owner of record: Rhombus 227 Kingsland Avenue Llc

8open violations
$0ECB/OATH penalties owed
2HPD class C (immediately hazardous)
44dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-09-17 (Accepted). Agency page

Dec 31, 2026
in 44 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 288 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 775 days
Next cycle year 2028

Open violations

ECB / OATH (2)
IssuedViolationHearingBalance
Nov 23, 2010Construction CLASS - 2
FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. REFRIGERATOR (BLOCKINGSIDE DOOR AT REAR ADJACENT TO PUBLIC STAIRWAY AT 1ST STORY. REMEDY: MAINTAIN BLDG FORTHWITH. REMOVE REFRIGERATOR IMMEDIATE
#34878339X
Jan 24, 2011
STIPULATION/IN-VIO
$0
Oct 21, 2010Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER DEFECT NOTED MULTIPLE DWELLING BLDG FRONT DOOR HAS NO DOOR KNOB ON LOCKING HARDWARE BLDG OPEN & UNSECURED UNDER MULTIPLE DWELLING LAW DOOR KNOB & LOCKING HARD
#34874094Z
Jul 11, 2011
IN VIOLATION
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (6) · C 2 · B 2 · A 2
IssuedClassViolationCorrect by
May 27, 2025C567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GJun 22, 2025
Apr 13, 2015BApt 5 · SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF WIRE TAPPED IN CIRCUIT BRAKER AT NORTH WALL IN THE FOYER LOCATED AT APT 5, 2nd STORY, 2nd APARTMENT FROM NORTH AT EASTMay 18, 2015
Apr 13, 2015BApt 5 · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS , IN THE ENTRANCE LOCATED AT APT 5, 2nd STORY, 2nd APARTMENT FROM NORTH AT EASTMay 18, 2015
Apr 13, 2015CApt 5 · SECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 6; WG TO REPLACE = 0; WG TO REPAIR = 0; LOCATED AT APT 5, 2nd STORY, 2nd APARTMENT FROM NORTH AMay 11, 2015
Apr 13, 2015ASECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYJul 17, 2015
Jun 5, 2008ASECTION 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO ANY FIRE ESCAPE OR SOIL OR VENT LINE NORTH CENTER.Sep 8, 2008

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 1:26 PM ET. BBL 3026880027.

Look up another building