6 floors · 25 apartments · 25,400 sq ft · built 1930 · class D6 · owner of record: 227-231 E 59th Partners Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 44 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 25,400 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 165 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 165 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 288 days | Registered through 2027-09-01 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-01 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 29, 2022 | Elevators CLASS - 1 DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMANS SERVICE PRESENT IN CONTROLLER. INSTALL FIREMANS SERVICE SO DLM IS IN COMPLIANCE WITH SECTION 3.10.12 OF APPENDIX K3. NO DOOR LOCK MONITORING INSTALLED IN THI #39059131J | Jul 14, 2022 IN VIOLATION | $1,250 |
| Jan 14, 2022 | Elevators CLASS - 1 42M7,8V1:42-M-7=DLM NOT INSTALLED ON THIS CONTROLLER AS MANDATED BY 3.10.12 OF THE APPENDIX K3 OF THE NYCBC. THIS IS A DEVICE THAT ENSURES PASSENGERS SAFETY. REMEDY FILE APPLICATION OBTAIN PERMIT AND INSTALL DL #38274240Y | Jun 2, 2022 DEFAULT | $3,125 |
| Oct 28, 2021 | Elevators CLASS - 1 FOUND DOOR RESTRICTOR'S PLUNGER MISSING. DOOR RESTRICTOR IS NOT WORKING. CEASE USED. REPLACE THE PLUNGER, REPAIR AND ADJUST. RE-INSPECTION IS REQUIRED. NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PE #39050236P | Jun 23, 2022 IN VIOLATION | $1,250 |
| Jul 9, 2020 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1, 27-542.AT THE TIME OF INSPECTION OBSERVED DEFECTIVE EMERGENCY LIGHT #35466361H | Feb 18, 2021 IN VIOLATION | $1,250 |
| Issued | Violation | Status |
|---|---|---|
| Apr 29, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2001060 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 8) | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Apr 29, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 21, 2025 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR AT COMPACTOR CLOSET, 2nd STORY | Dec 5, 2025 |
| Nov 21, 2025 | B | Apt 1D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FT AT FLOOR IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 1D, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 25, 2026 |
| Sep 4, 2025 | C | Apt 4C · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 18, 2025 |
| Jan 10, 2025 | B | Apt 1D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COVER TO ELECTRIC OUTLET AT EAST WALL. IN THE BATHROOM LOCATED AT APT 1D, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 14, 2025 |
| Jan 10, 2025 | C | Apt 1D · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER EXCEEDING A MAXIMUM OF 130F DEGREES AT ALL HOT WATER FIXTURES . IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 16, 2025 |
| Sep 12, 2023 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS AT VESTIBULE DOOR TO PUBLIC HALL, 1ST STY. | Oct 17, 2023 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 7:35 PM ET. BBL 1014140013.