Brooklyn · Block 7153 · Lot 27 · 11223

2266 East 2 Street

2 floors · 2 apartments · 2,788 sq ft · built 1930 · class B2 · owner of record: 2266 Realty Llc

9open violations
$33,750ECB/OATH penalties owed
0HPD class C (immediately hazardous)
291dto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Required only if the owner doesn't live there

Open violations

ECB / OATH (8) · $33,750 owed
IssuedViolationHearingBalance
Sep 17, 2026Construction CLASS - 2
WORK WITHOUT PERMIT, I OBSERVED AN INCOMPLETE 3 PIECE BATHROOM INSTALLED IN CELLAR, AND FUTURE GAS CONNECTION CREATED IN BOILER ROOM, WITH REMOVAL OF GAS FIRED APPLIANCES AND NEW GAS FITTINGS WITH NO PERMITS IN
#39204490J
Nov 25, 2026
PENDING
$1,250
Sep 17, 2026Construction CLASS - 1
WORK WITHOUT PERMIT: PSWO ISSUED FOR ALL GENERAL CONSTRUCTION, CARPENTRY AND STRUCTURAL WORK BEING DONE ON THE RESIDENT. ATOI OBSERVED AN UNPERMITTED UNDOCUMENTED TWO STORY HORIZONTAL AND VERTICAL EXTENSION ATT
#39204575Z
Nov 25, 2026
PENDING
$2,500
Sep 17, 2026Unknown CLASS - 1
WORK WITHOUT PERMIT. PSWO ISSUED FOR ALL ELECTRICAL WORK BEING DONE . ATOI AT 1 PM OBSERVED IN THE INTERIOR AND EXTERIOR OF THE RESIDENT FROM THE BASEMENT TO THE SECOND FLOOR NEWLY INSTALLED ELECTRICAL WORK CON
#39204576K
Nov 25, 2026
PENDING
$2,500
Sep 17, 2026Construction CLASS - 1
ECB VIOLATING ISSUED FOR FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER: ATOI OBSERVED IN THE INTERIOR OF THE RESIDENT NO GUARD RAIL AND HAND RAIL SYSTEM ON THE STAIRCASES FROM THE BASEMENT TO THE SECOND
#39204577M
Nov 25, 2026
PENDING
$2,500
Jun 15, 2026Construction CLASS - 1
WORK WITHOUT PERMIT. PSWO ISSUED FOR ALL EXTERIOR FACADE WORK. ATOI OBSERVED AT EXPO # 1 1ST AND 2ND FLOOR FACADE REMOVED AND REPLACED WITH A STUCCO FINISH BRICK COLUMNS WERE REMOVED FROM THE FRONT PORCH. WINDO
#39192515L
Aug 26, 2026
DEFAULT
$12,500
Jun 15, 2026Construction CLASS - 1
ECB VIOLATING ISSUED FOR FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER: ATOI OBSERVED NO GUARD SYSTEM ON THE RESIDENTS PORCH AT EXPO # 1. WHICH IS A FALL HAZZARD FOR THE PUBLIC AND RESIDENT, REPAIR AND/
#39192520X
Aug 26, 2026
DEFAULT
$12,500
Apr 1, 2024Construction CLASS - 1
INSPECTOR OBSERVED ON ALL LEVELS, CELLAR,1ST AND 2ND FLOORS COMPLETE GUT RENOVATION, IN REAR CREATED NEW EXTENSION APPROXIMATELY 16' IN LENGTH. OBSERVED NEW FLOOR JOISTS, PARTITIONS, ELECTRIC LINES AND PLUMBING
#39110395Y
Jun 12, 2024
ADMIT/IN-VIO
$0
Mar 6, 2024Construction CLASS - 2
RCA WAS ISSUED ON 9/08/2023 BY INSPECTOR BADGE # 3493 FOR FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. RCA NOT CORRECTED. AT TIME OF INSPECTION OBSERVED OF A 2 STORY BLDG. AT EXPOSURE # 1, FRONT PORCH
#39107946Y
May 15, 2024
ADMIT/IN-VIO
$0
DOB (1)
IssuedViolationStatus
Jun 7, 2023CONSTRUCTION
AT TIME OF INSPECTION OBSERVED GUT RENOVATION ON ALL FLOORS. NEW FRAMING AND REAR EXTENSION,NEW ELECTRIC LINES, WATER AND WASTE LINES AND GAS LINES. NO PERMITS ISSUED FOR THIS WORK.
#23-01804
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 17, 2026ECBConstruction: WORK WITHOUT PERMIT, I OBSERVED AN INCOMPLETE 3 PIECE BATHROOM INSTALLED IN CELLAR, AND FUTURE GAS CONNECTION CREATED IN BOILER ROOM, WITH REMOVAL OF GAS FIRED APPLIANCES AND NEW GAS FITTINGS WITH NO PERMITS INOpen
Sep 17, 2026ECBConstruction: WORK WITHOUT PERMIT: PSWO ISSUED FOR ALL GENERAL CONSTRUCTION, CARPENTRY AND STRUCTURAL WORK BEING DONE ON THE RESIDENT. ATOI OBSERVED AN UNPERMITTED UNDOCUMENTED TWO STORY HORIZONTAL AND VERTICAL EXTENSION ATTOpen
Sep 17, 2026ECBUnknown: WORK WITHOUT PERMIT. PSWO ISSUED FOR ALL ELECTRICAL WORK BEING DONE . ATOI AT 1 PM OBSERVED IN THE INTERIOR AND EXTERIOR OF THE RESIDENT FROM THE BASEMENT TO THE SECOND FLOOR NEWLY INSTALLED ELECTRICAL WORK CONOpen
Sep 17, 2026ECBConstruction: ECB VIOLATING ISSUED FOR FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER: ATOI OBSERVED IN THE INTERIOR OF THE RESIDENT NO GUARD RAIL AND HAND RAIL SYSTEM ON THE STAIRCASES FROM THE BASEMENT TO THE SECONDOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 10:51 PM ET. BBL 3071530027.